{"id":16263,"date":"2015-09-01T17:36:27","date_gmt":"2015-09-01T16:36:27","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16263"},"modified":"2026-06-29T16:46:06","modified_gmt":"2026-06-29T14:46:06","slug":"vse-o-automatickem-statickem-hydraulickem-vyvazovani","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/cs\/2015\/09\/01\/tout-sur-lequilibrage-hydraulique-statiqueautomatique\/","title":{"rendered":"V\u0161e o statick\u00e9m a automatick\u00e9m hydraulick\u00e9m vyva\u017eov\u00e1n\u00ed"},"content":{"rendered":"<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/mapsec.fr\/cs\/kontakt\/\" style=\"border-radius:2px\">po\u017e\u00e1dat o cenovou nab\u00eddku <\/a><\/div>\n<\/div>\n\n\n<p class=\"text-right small\" style=\"text-align: right;\">Autor: Patrick DELPECH \u2013 pro spole\u010dnost MAPSEC \u2013 b\u0159ezen 2020<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><em>Pro technick\u00e9 vedouc\u00ed a osoby s rozhodovac\u00ed pravomoc\u00ed (stavebn\u00ed zadavatel\u00e9, spr\u00e1vci nemovitost\u00ed atd.) \u2013 novinky v oboru, \u00faskal\u00ed, kter\u00fdm je t\u0159eba se vyhnout, a podm\u00ednky pro spr\u00e1vn\u00e9 proveden\u00ed hydraulick\u00e9ho a tepeln\u00e9ho vyv\u00e1\u017een\u00ed.<\/em><\/p>\n<p>Tato str\u00e1nka p\u0159edstavuje obecn\u00e9 z\u00e1sady statick\u00e9ho a automatick\u00e9ho hydraulick\u00e9ho vyva\u017eov\u00e1n\u00ed.<\/p>\n<p>Chcete-li se sezn\u00e1mit s metodou MAPSEC aplikovanou na s\u00edt\u011b d\u00e1lkov\u00e9ho vyt\u00e1p\u011bn\u00ed, v\u010detn\u011b diagnostiky, m\u011b\u0159en\u00ed, nastaven\u00ed, ov\u011b\u0159en\u00ed a metody EQUILOG, nav\u0161tivte na\u0161i hlavn\u00ed str\u00e1nku v\u011bnovanou\u2019<a href=\"https:\/\/mapsec.fr\/cs\/2016\/01\/13\/vyvazeni-hydraulickeho-systemu-topeni-bezplatna-diagnostika\/\">vyv\u00e1\u017een\u00ed hydraulick\u00e9ho syst\u00e9mu v syst\u00e9mu centr\u00e1ln\u00edho vyt\u00e1p\u011bn\u00ed<\/a>.<\/p>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>PROBLEMATIKA<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Pokud se v r\u00e1mci jednoho topn\u00e9ho okruhu vyskytuj\u00ed sou\u010dasn\u011b p\u0159\u00edli\u0161 vyt\u00e1p\u011bn\u00e9 i nedostate\u010dn\u011b vyt\u00e1p\u011bn\u00e9 m\u00edstnosti, je to p\u0159\u00edznakem velmi \u010dast\u00e9ho probl\u00e9mu s nevyv\u00e1\u017eenost\u00ed syst\u00e9mu.<br \/>A\u0165 u\u017e je skute\u010dn\u00e1 p\u0159\u00ed\u010dina jak\u00e1koli \u2013 nespr\u00e1vn\u00e9 nastaven\u00ed hydrauliky, chyby v dimenzov\u00e1n\u00ed, pou\u017eit\u00ed nesourod\u00fdch izola\u010dn\u00edch materi\u00e1l\u016f atd. \u2013, lze tento probl\u00e9m vy\u0159e\u0161it nastaven\u00edm takzvan\u00fdch vyva\u017eovac\u00edch ventil\u016f, pokud jsou tyto ventily spr\u00e1vn\u011b rozm\u00edst\u011bny a dostate\u010dn\u011b p\u0159\u00edstupn\u00e9.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Regula\u010dn\u00ed T-kus a objemov\u00fd ventil\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec1.jpg\" alt=\"\" width=\"529\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 1: Nastavovac\u00ed T-kus a objemov\u00fd ventil <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Je t\u0159eba prov\u00e9st nastaven\u00ed tak, aby se omezil pr\u016ftok u up\u0159ednost\u0148ovan\u00fdch odbo\u010dek, \u010d\u00edm\u017e se p\u0159i jejich poklesu zv\u00fd\u0161\u00ed pr\u016ftok u up\u0159ednost\u0148ovan\u00fdch odbo\u010dek.<\/p>\n<p>Princip nastaven\u00ed je tedy snadno srozumiteln\u00fd, jeho proveden\u00ed je v\u0161ak mnohem slo\u017eit\u011bj\u0161\u00ed. V tomto \u010dl\u00e1nku se podrobn\u011bji zab\u00fdv\u00e1me podm\u00ednkami, za kter\u00fdch prob\u011bhne hydraulick\u00e9 vyv\u00e1\u017een\u00ed spr\u00e1vn\u011b, zejm\u00e9na u st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00ed.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANAL\u00ddZA A ODBORN\u00c9 ZNALOSTI PROJEKTOV\u00ddCH KANCEL\u00c1\u0158\u00cd<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Obecn\u011b \u0159e\u010deno, rozvod topn\u00e9 vody <strong>st\u00e1vaj\u00edc\u00ed<\/strong> lze snadno vyv\u00e1\u017eit pouze v p\u0159\u00edpad\u011b, \u017ee jsou nainstalov\u00e1ny vyva\u017eovac\u00ed ventily <u>dostupn\u00e9<\/u>, mimo obsazen\u00e9 prostory.<br \/>Pokud za\u0159\u00edzen\u00ed nen\u00ed p\u0159\u00edli\u0161 star\u00e9, projektanti to obvykle p\u0159i jeho navrhov\u00e1n\u00ed zohlednili a zajistili instalaci takzvan\u00fdch 2-polohov\u00fdch ventil\u016f<sup>t\u00e9ma<\/sup> vyrovn\u00e1vac\u00ed patra, kter\u00e1 se nach\u00e1zej\u00ed v suter\u00e9nech, podzemn\u00edch prostorech, p\u0159\u00edpadn\u011b ve schodi\u0161t\u00edch, a v ka\u017ed\u00e9m p\u0159\u00edpad\u011b mimo ob\u00fdvan\u00e9 prostory.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Ventily 2. stupn\u011b vyva\u017eov\u00e1n\u00ed \" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec2.jpg\" alt=\"\" width=\"650\" height=\"357\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek 2: Dva kohoutky<sup>t\u00e9ma<\/sup> \u00farove\u0148 vyv\u00e1\u017een\u00ed<\/em><\/p>\n<p class=\"text-justify push-top\">Okruhy, kter\u00e9 jsou vybaveny pouze vyva\u017eovac\u00edmi ventily namontovan\u00fdmi na radi\u00e1torech, se vyva\u017euj\u00ed obt\u00ed\u017en\u011b, proto\u017ee je velmi slo\u017eit\u00e9 zajistit soub\u011b\u017en\u00fd p\u0159\u00edstup do v\u0161ech m\u00edstnost\u00ed, pokud jsou obsazen\u00e9.<\/p>\n<p>V t\u00e9to situaci je t\u0159eba nechat rozvodnou s\u00ed\u0165 prov\u011b\u0159it projek\u010dn\u00ed kancel\u00e1\u0159\u00ed nebo odborn\u00edkem na vyva\u017eov\u00e1n\u00ed, aby se zjistily mo\u017enosti instalace p\u0159\u00edstupn\u00fdch ventil\u016f 2<sup>t\u00e9ma<\/sup> \u00farove\u0148.<br \/>Je t\u0159eba poznamenat, \u017ee vyv\u00e1\u017een\u00ed obvodu bude t\u00edm \u00fa\u010dinn\u011bj\u0161\u00ed, \u010d\u00edm v\u011bt\u0161\u00ed bude po\u010det vys\u00edla\u010d\u016f \u00ab\u0159\u00edzen\u00fdch\u00bb regul\u00e1tory 2<sup>t\u00e9ma<\/sup> \u00darove\u0148 bude m\u00edrn\u00e1, s optim\u00e1ln\u00edm po\u010dtem 5 a\u017e 10 jednotek.<\/p>\n<p>U st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00ed se zpravidla nastavuje pouze 2<sup>t\u00e9ma<\/sup> \u00darove\u0148 vyv\u00e1\u017een\u00ed (a vy\u0161\u0161\u00ed \u00farovn\u011b) posta\u010duje k dosa\u017een\u00ed spr\u00e1vn\u00e9ho v\u00fdsledku. Pokud by p\u0159esto u n\u011bkter\u00fdch konkr\u00e9tn\u00edch ant\u00e9n p\u0159etrv\u00e1valy poruchy, bude v\u017edy mo\u017en\u00e9 prov\u00e9st na m\u00edst\u011b dodate\u010dn\u00e9 vyv\u00e1\u017een\u00ed. To bude mo\u017en\u00e9 prov\u00e9st spr\u00e1vn\u011b, proto\u017ee p\u0159\u00edslu\u0161n\u00e1 skupina vys\u00edla\u010d\u016f bude p\u0159edem norm\u00e1ln\u011b nap\u00e1jena d\u00edky spr\u00e1vn\u00e9mu nastaven\u00ed sv\u00e9ho ventilu 2<sup>t\u00e9ma<\/sup> \u00farove\u0148.<\/p>\n<p>Pokud se instaluj\u00ed vyva\u017eovac\u00ed ventily o pr\u016fm\u011bru 2<sup>t\u00e9ma<\/sup> Pokud nebude mo\u017en\u00e9 dos\u00e1hnout t\u00e9to \u00farovn\u011b, bude nutn\u00e9 zv\u00e1\u017eit n\u00e1ro\u010dn\u00fd pl\u00e1n p\u0159\u00edstupu do v\u0161ech prostor.<br \/>Pokud u\u017e se rozhodneme pro toto n\u00e1kladn\u00e9 \u0159e\u0161en\u00ed, m\u016f\u017eeme toho vyu\u017e\u00edt a nechat prov\u00e9st studii mo\u017enosti instalace termostatick\u00fdch ventil\u016f nejnov\u011bj\u0161\u00ed generace, kter\u00e9 nav\u00edc zaji\u0161\u0165uj\u00ed \u00abdynamick\u00e9\u00bb vyv\u00e1\u017een\u00ed, jeho\u017e v\u00fdhody prozkoum\u00e1me pozd\u011bji.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Hydraulicky dynamick\u00e9 termostatick\u00e9 ventily Danfoss\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec3.jpg\" alt=\"\" width=\"300\" height=\"251\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek 3: Hydraulicky dynamick\u00e9 termostatick\u00e9 ventily <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Na z\u00e1v\u011br je t\u0159eba poznamenat, \u017ee nastaven\u00ed t\u011bchto ventil\u016f vy\u017eaduje, stejn\u011b jako u v\u0161ech vyva\u017eovac\u00edch ventil\u016f, p\u0159esn\u00e9 po\u010d\u00e1te\u010dn\u00ed hydraulick\u00e9 se\u0159\u00edzen\u00ed.<br \/>Jak uvid\u00edme pozd\u011bji, pokud se vyva\u017eov\u00e1n\u00ed prov\u00e1d\u00ed nastaven\u00edm pr\u016ftok\u016f, bude k jejich stanoven\u00ed \u2013 v p\u0159\u00edpad\u011b, \u017ee neexistuj\u00ed z\u00e1znamy o st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00edch \u2013 zapot\u0159eb\u00ed zapojen\u00ed projek\u010dn\u00ed kancel\u00e1\u0159e.<\/p>\n<p class=\"text-justify push-top\">\u00a0<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANAL\u00ddZA A ODBORN\u00c9 ZNALOSTI PR\u016eMYSLN\u00cdK\u016e<\/h2>\n<\/div>\n<p class=\"text-justify push-top\"><em>Sou\u010dasn\u011b existuj\u00ed t\u0159i generace vyva\u017eovac\u00edch ventil\u016f.<\/em><\/p>\n<p><strong>1<sup>\u00e9ra<\/sup> generace: Statick\u00e9 a nevolumetrick\u00e9 vyva\u017eovac\u00ed ventily.<\/strong><br \/>Tyto ventily neumo\u017e\u0148uj\u00ed m\u011b\u0159en\u00ed pr\u016ftoku v potrub\u00ed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Nevolumetrick\u00e9 vyrovn\u00e1vac\u00ed ventily\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec18.jpg\" alt=\"\" width=\"650\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\"><em>Obr\u00e1zek 4: Nevolumetrick\u00e9 vyva\u017eovac\u00ed ventily<\/em><\/p>\n<p class=\"text-justify push-top\">K jejich nastaven\u00ed slou\u017e\u00ed dv\u011b metody:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Hydraulick\u00e1 simulace rozvod\u016f<\/li>\n<li class=\"pad5\">Sjednocen\u00ed teplot zp\u011btn\u00e9ho toku ant\u00e9n, kter\u00e9 je t\u0159eba vyv\u00e1\u017eit<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Hydraulick\u00e1 simulace rozvodn\u00fdch s\u00edt\u00ed p\u0159edpokl\u00e1d\u00e1 podrobn\u00fd pr\u016fzkum rozvodn\u00e9 s\u00edt\u011b (d\u00e9lky \u00fasek\u016f, pr\u016fm\u011bry atd.), stanoven\u00ed hydraulick\u00e9ho chov\u00e1n\u00ed nainstalovan\u00fdch ventil\u016f a v\u00fdpo\u010det pr\u016ftok\u016f, kter\u00e9 je t\u0159eba nastavit na ka\u017ed\u00e9m odbo\u010dkov\u00e9m potrub\u00ed.<br \/>U st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00ed je shrom\u00e1\u017ed\u011bn\u00ed v\u0161ech t\u011bchto \u00fadaj\u016f slo\u017eit\u00e9 a z toho vypl\u00fdvaj\u00edc\u00ed nejistoty sni\u017euj\u00ed \u0161ance na snadn\u00e9 dosa\u017een\u00ed dobr\u00e9ho v\u00fdsledku.<\/p>\n<p>Jsou-li za\u0159\u00edzen\u00ed vybavena kohoutky tohoto typu, nejlep\u0161\u00edm \u0159e\u0161en\u00edm je postupovat n\u00e1sledovn\u011b: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/methode-dequilibrage-equilog\/\" target=\"_blank\" rel=\"noopener noreferrer\">vyrovn\u00e1n\u00ed teplot zp\u011btn\u00e9ho toku vody v jednotliv\u00fdch okruhu, kter\u00e9 maj\u00ed b\u00fdt vyv\u00e1\u017eeny. <\/a><br \/>Tato nov\u00e1 metoda bude p\u0159edstavena d\u00e1le.<\/p>\n<p><strong>2<sup>t\u00e9ma<\/sup> generace: Statick\u00e9 a objemov\u00e9 vyva\u017eovac\u00ed ventily.<\/strong><br \/>Tyto ventily umo\u017e\u0148uj\u00ed m\u011b\u0159en\u00ed pr\u016ftoku v potrub\u00ed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Objemov\u00e9 vyrovn\u00e1vac\u00ed ventily\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec5.jpg\" alt=\"\" width=\"451\" height=\"230\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 5: Objemov\u00e9 vyva\u017eovac\u00ed ventily <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> a <a class=\"bleu\" href=\"http:\/\/www.comap.fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">Comap<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Existuj\u00ed t\u0159i zp\u016fsoby, jak je nastavit:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Hydraulick\u00e1 simulace rozvod\u016f<\/li>\n<li class=\"pad5\">Nastaven\u00ed a kontrola pr\u016ftok\u016f na z\u00e1klad\u011b m\u011b\u0159en\u00ed na m\u00edst\u011b<\/li>\n<li class=\"pad5\">Sjednocen\u00ed teplot zp\u011btn\u00e9ho toku vody v pobo\u010dk\u00e1ch, kter\u00e9 je t\u0159eba vyv\u00e1\u017eit<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Pokud prvn\u00ed \u0159e\u0161en\u00ed vylou\u010d\u00edme vzhledem k obt\u00ed\u017e\u00edm, kter\u00e9 s sebou nese u st\u00e1vaj\u00edc\u00edch instalac\u00ed, je t\u0159eba poznamenat, \u017ee pr\u00e1ce spo\u010d\u00edvaj\u00edc\u00ed v nastaven\u00ed pr\u016ftok\u016f rovn\u011b\u017e vy\u017eaduje zapojen\u00ed projek\u010dn\u00ed kancel\u00e1\u0159e, kter\u00e1 ur\u010d\u00ed pr\u016ftok, na kter\u00fd je t\u0159eba nastavit ka\u017edou ant\u00e9nu, u n\u00ed\u017e je t\u0159eba prov\u00e9st vyv\u00e1\u017een\u00ed.<br \/>U st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00ed z\u016fst\u00e1v\u00e1 nejjednodu\u0161\u0161\u00edm \u0159e\u0161en\u00edm sjednocen\u00ed teplot zp\u011btn\u00e9ho toku vody.<\/p>\n<p><strong>3<sup>t\u00e9ma<\/sup> generace: Dynamick\u00e9 vyva\u017eovac\u00ed ventily<\/strong><br \/>Jedn\u00e1 se o nejnov\u011bj\u0161\u00ed generaci vyva\u017eovac\u00edch ventil\u016f, kter\u00e9 jsou ur\u010deny k instalaci na <strong>okruhy s prom\u011bnn\u00fdm pr\u016ftokem <\/strong>jako nap\u0159\u00edklad ty, kter\u00e9 jsou vybaveny termostatick\u00fdmi ventily.<\/p>\n<p>Je t\u0159eba rozli\u0161ovat mezi dv\u011bma typy kohoutk\u016f:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Vyrovn\u00e1vac\u00ed ventily nebo armatury \u00ab <em>regul\u00e1tory diferen\u010dn\u00edho tlaku <\/em>\u00bb<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Regula\u010dn\u00ed ventily pro diferen\u010dn\u00ed tlak\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec7.jpg\" alt=\"\" width=\"650\" height=\"207\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 6: Ventily pro regulaci diferen\u010dn\u00edho tlaku <a class=\"bleu\" href=\"http:\/\/honeywell.com\/country\/fr\/Pages\/home.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">Honeywell<\/a> a <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">V rozvodu vybaven\u00e9m termostatick\u00fdmi ventily (Rth) se p\u0159i jejich \u00abuzav\u0159en\u00ed\u00bb zvy\u0161uje rozd\u00edl p\u0159\u00edvodn\u00edho tlaku (DP) v odbo\u010dce. Tento n\u00e1r\u016fst DP pak br\u00e1n\u00ed uzav\u0159en\u00ed termostatick\u00fdch ventil\u016f Rth a vede ke zv\u00fd\u0161en\u00ed pr\u016ftoku ve vys\u00edla\u010d\u00edch, jejich\u017e termostatick\u00e9 ventily se je\u0161t\u011b neuzav\u0159ely.<br \/>V t\u00e9to situaci regul\u00e1tor diferen\u010dn\u00edho tlaku zaznamen\u00e1 n\u00e1r\u016fst diferen\u010dn\u00edho tlaku a \u00abuzav\u0159e se\u00bb, aby jej obnovil.<\/p>\n<p>N\u011bkter\u00e9 modely, jako nap\u0159\u00edklad ty na fotografii v\u00fd\u0161e, nejsou objemov\u00e9, a proto neumo\u017e\u0148uj\u00ed m\u011b\u0159en\u00ed regulovan\u00fdch pr\u016ftok\u016f. Jejich nastaven\u00ed nebo kontrola nastaven\u00ed se mus\u00ed prov\u00e1d\u011bt m\u011b\u0159en\u00edm teplot v zp\u011btn\u00e9m potrub\u00ed.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>t\u00e9ma<\/sup> Typy dynamick\u00fdch vyva\u017eovac\u00edch ventil\u016f: Automatick\u00e9 vyva\u017eovac\u00ed ventily<\/strong> <em>(naz\u00fdvan\u00e9 tak\u00e9 samovyva\u017eovac\u00ed nebo nez\u00e1visl\u00e9 na p\u0159\u00edvodn\u00edm tlaku, PIBCV nebo regul\u00e1tory pr\u016ftoku)<\/em><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Takzvan\u00e9 \u00abautomatick\u00e9\u00bb vyva\u017eovac\u00ed ventily\u00bb\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec8.jpg\" alt=\"\" width=\"250\" height=\"253\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 7: Takzvan\u00e9 \u00abautomatick\u00e9\u00bb vyva\u017eovac\u00ed ventily\u00bb <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Tyto kohoutky byly navr\u017eeny tak, aby umo\u017e\u0148ovaly <strong>nastaven\u00ed jedn\u00e9 koncov\u00e9 jednotky<\/strong> jako nap\u0159\u00edklad topn\u00e1 baterie v klimatiza\u010dn\u00ed jednotce (CTA) nebo v konvektorov\u00e9m ventil\u00e1toru.<br \/>Mohou b\u00fdt vybaveny pohonem, co\u017e umo\u017e\u0148uje regulaci jednotky tak, aby dosahovala optim\u00e1ln\u00edch hydraulick\u00fdch provozn\u00edch podm\u00ednek.<\/p>\n<p>N\u011bkdy se pou\u017e\u00edvaj\u00ed k vyv\u00e1\u017een\u00ed ant\u00e9n, kter\u00e9 obsahuj\u00ed <strong>n\u011bkolik rozvod\u016f vybaven\u00fdch dvoucestn\u00fdmi regula\u010dn\u00edmi ventily<\/strong> jako jsou nap\u0159\u00edklad radi\u00e1tory vybaven\u00e9 termostatick\u00fdmi ventily. Automatick\u00e9 vyva\u017eovac\u00ed ventily tak nahrazuj\u00ed ventily pro regulaci diferen\u010dn\u00edho tlaku, kter\u00e9 se v takov\u00e9m p\u0159\u00edpad\u011b obvykle pou\u017e\u00edvaj\u00ed.<\/p>\n<p>Tato situace nebyla p\u016fvodn\u011b p\u0159edpokl\u00e1d\u00e1na a nen\u00ed zm\u00edn\u011bna v technick\u00fdch specifikac\u00edch v\u00fdrobc\u016f. Funkce automatick\u00e9ho vyva\u017eovac\u00edho ventilu toti\u017e v takov\u00e9m p\u0159\u00edpad\u011b nen\u00ed zcela optim\u00e1ln\u00ed a v t\u00e9to situaci se podob\u00e1 fungov\u00e1n\u00ed statick\u00e9ho vyva\u017eovac\u00edho ventilu.<\/p>\n<p>Tento princip fungov\u00e1n\u00ed si m\u016f\u017eeme prostudovat v n\u00e1sleduj\u00edc\u00edm \u010dl\u00e1nku: <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u00abAutomatick\u00e9 vyva\u017eov\u00e1n\u00ed \u2013 podm\u00ednky \u00fasp\u011bchu\u00bb<\/a><\/p>\n<p>V koment\u00e1\u0159\u00edch na konci tohoto \u010dl\u00e1nku si m\u016f\u017eete p\u0159e\u010d\u00edst stanovisko dvou velk\u00fdch v\u00fdrobc\u016f.<br \/>Spole\u010dnost IMI \u2013 Hydronic tedy up\u0159es\u0148uje:<br \/><em>\u00abPokud jde o instalaci automatick\u00fdch ventil\u016f (PIBCV, v tomto p\u0159\u00edpad\u011b regul\u00e1tor pr\u016ftoku) v rozvodech s prom\u011bnn\u00fdm pr\u016ftokem (nap\u0159\u00edklad v bytech vybaven\u00fdch termostatick\u00fdmi ventily) n\u00e1m na\u0161e role odborn\u00edk\u016f a pr\u016fmyslov\u00fdch specialist\u016f na hydrauliku ukl\u00e1d\u00e1 povinnost vyjad\u0159ovat se technicky bezchybn\u011b. I kdy\u017e je t\u0159eba konstatovat, \u017ee se instalace PIBCV na vstupu do byt\u016f st\u00e1le v\u00edce roz\u0161i\u0159uje, z etick\u00e9ho hlediska tuto praxi nem\u016f\u017eeme podporovat.\u00bb<\/em><\/p>\n<p>Oventrop se k tomuto t\u00e9matu vyjad\u0159uje pragmati\u010dt\u011bji a uv\u00e1d\u00ed <em>\u017ee i kdy\u017e doch\u00e1z\u00ed k ur\u010dit\u00e9mu technick\u00e9mu kompromisu v oblasti hydrauliky, celkov\u00e9 nastaven\u00ed dosa\u017een\u00e9 pomoc\u00ed automatick\u00fdch ventil\u016f je p\u0159esto mnohem lep\u0161\u00ed ne\u017e nastaven\u00ed dosa\u017een\u00e9 pomoc\u00ed statick\u00fdch ventil\u016f a regul\u00e1tor\u016f tlaku, proto\u017ee ty jsou ve v\u011bt\u0161in\u011b p\u0159\u00edpad\u016f nastaveny jen minim\u00e1ln\u011b nebo v\u016fbec.<\/em><\/p>\n<p>Nastaven\u00ed ventil\u016f pro regulaci diferen\u010dn\u00edho tlaku skute\u010dn\u011b \u010dasto nen\u00ed ide\u00e1ln\u00ed, zejm\u00e9na u model\u016f, kter\u00e9 nejsou objemov\u00e9. Pokud se nepracuje na z\u00e1klad\u011b m\u011b\u0159en\u00ed teploty zp\u011btn\u00e9ho toku, lze jejich nastaven\u00ed prov\u00e9st pouze na z\u00e1klad\u011b hypotetick\u00e9ho v\u00fdpo\u010dtu tlakov\u00e9 ztr\u00e1ty. Pokud chceme prov\u00e9st vyv\u00e1\u017een\u00ed na z\u00e1klad\u011b m\u011b\u0159en\u00ed pr\u016ftoku, je nezbytn\u00e9 zvolit objemov\u00e9 modely; n\u011bkolik zna\u010dek nab\u00edz\u00ed p\u0159izp\u016fsobiteln\u00e9 objemov\u00e9 ventily.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Objemov\u00fd ventil vybaven\u00fd regul\u00e1torem diferen\u010dn\u00edho tlaku Oventrop\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec17.jpg\" alt=\"\" width=\"513\" height=\"150\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 6 bis: Objemov\u00fd ventil vybaven\u00fd ventilem pro regulaci diferen\u010dn\u00edho tlaku <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Na z\u00e1v\u011br tedy p\u0159edev\u0161\u00edm zd\u016fraz\u0148ujeme, \u017ee nesm\u00ed doj\u00edt k z\u00e1m\u011bn\u011b pojm\u016f \u00abmont\u00e1\u017e kohoutk\u016f\u00bb a \u00abse\u0159\u00edzen\u00ed kohoutk\u016f\u00bb, a to bez ohledu na generaci nainstalovan\u00fdch model\u016f.<\/p>\n<p>Stejn\u011b jako u p\u0159edchoz\u00edch generac\u00ed je t\u0159eba i u dynamick\u00fdch vyva\u017eovac\u00edch ventil\u016f prov\u00e9st pe\u010dliv\u00e9 po\u010d\u00e1te\u010dn\u00ed se\u0159\u00edzen\u00ed. Toto se\u0159\u00edzen\u00ed lze prov\u00e9st pomoc\u00ed simulace a\/nebo m\u011b\u0159en\u00ed pr\u016ftoku a\/nebo m\u011b\u0159en\u00ed teplot v zp\u011btn\u00e9m potrub\u00ed. T\u00e9to t\u00e9matice se budeme podrobn\u011bji v\u011bnovat v n\u00e1sleduj\u00edc\u00edm odstavci.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>METODY VYV\u00c1\u017dEN\u00cd<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">U st\u00e1vaj\u00edc\u00edch syst\u00e9m\u016f d\u00e1lkov\u00e9ho vyt\u00e1p\u011bn\u00ed, <strong>t\u0159i metodiky <\/strong>Dnes se pou\u017e\u00edvaj\u00ed postupy pro po\u010d\u00e1te\u010dn\u00ed se\u0159\u00edzen\u00ed vyva\u017eovac\u00edch ventil\u016f.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>1<sup>\u00e9ra<\/sup> metoda: Simulace hydraulick\u00e9ho chov\u00e1n\u00ed s\u00edt\u00ed<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Simulace  hydraulick\u00e9ho chov\u00e1n\u00ed s\u00edt\u00ed\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec9.jpg\" alt=\"\" width=\"492\" height=\"446\" \/><\/p>\n<p class=\"text-justify push-top\">U st\u00e1vaj\u00edc\u00edch instalac\u00ed je teoreticky mo\u017en\u00e9 prov\u00e9st m\u011b\u0159en\u00ed nezbytn\u00e1 k odhadu pr\u016ftok\u016f a tlakov\u00fdch ztr\u00e1t v okruz\u00edch, aby bylo mo\u017en\u00e9 na jejich z\u00e1klad\u011b v\u00fdpo\u010dtem ur\u010dit p\u0159ednastaven\u00ed vyva\u017eovac\u00edch ventil\u016f. Jedn\u00e1 se v\u0161ak o n\u00e1ro\u010dnou \u00abstopova\u010dku\u00bb, pokud nevyu\u017eijeme rozvodn\u00e9 pl\u00e1ny, kter\u00e9 jsou m\u00e1lokdy k dispozici.<\/p>\n<p>Tuto mo\u017enost, kterou obzvl\u00e1\u0161t\u011b rozvinul <a class=\"bleu\" href=\"http:\/\/edipa.fr\/LibrairieTechnique\/Auteur?auteur=FRIDMANN%20Pierre&amp;page=1\" target=\"_blank\" rel=\"noopener noreferrer\">Pan Pierre Fridmann<\/a> vy\u017eaduje mo\u017enost n\u00e1sledn\u00e9 kontroly v\u00fdsledk\u016f v\u0161ech proveden\u00fdch p\u0159ednastaven\u00ed, a to bu\u010f m\u011b\u0159en\u00edm pr\u016ftok\u016f, nebo m\u011b\u0159en\u00edm teplot zp\u011btn\u00e9 vody.<\/p>\n<p>Tato metoda se vztahuje sp\u00ed\u0161e na nov\u00e9 nebo relativn\u011b nov\u00e9 za\u0159\u00edzen\u00ed, u nich\u017e dosud nedoch\u00e1z\u00ed k nep\u0159edv\u00eddateln\u00e9mu zan\u00e1\u0161en\u00ed a pro kter\u00e1 jsou k dispozici v\u0161echny pot\u0159ebn\u00e9 v\u00fdpo\u010dtov\u00e9 \u00fadaje.<br \/>Lze ji zejm\u00e9na pou\u017e\u00edt k ur\u010den\u00ed tlakov\u00fdch rozd\u00edl\u016f, kter\u00e9 je t\u0159eba nastavit na ventilech typu \u00abregul\u00e1tory diferen\u010dn\u00edho tlaku\u00bb, kter\u00e9 maj\u00ed stupnici nastaven\u00ed v jednotk\u00e1ch tlaku.<br \/>V\u00fdsledek simulace umo\u017e\u0148uje prov\u00e9st p\u0159ednastaven\u00ed armatur, ne\u017e se n\u00e1sledn\u011b na m\u00edst\u011b zkontroluj\u00ed a uprav\u00ed skute\u010dn\u011b nam\u011b\u0159en\u00e9 pr\u016ftoky vody nebo teploty zp\u011btn\u00e9 vody.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>t\u00e9ma<\/sup> metoda: V\u00fdpo\u010det, nastaven\u00ed a kontrola pr\u016ftok\u016f, kter\u00e9 maj\u00ed b\u00fdt p\u0159epravov\u00e1ny<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Metodika spo\u010d\u00edv\u00e1 ve v\u00fdpo\u010dtu a nastaven\u00ed pr\u016ftok\u016f, kter\u00e9 maj\u00ed b\u00fdt p\u0159epravov\u00e1ny. Vy\u017eaduje samoz\u0159ejm\u011b pou\u017eit\u00ed takzvan\u00fdch \u00abobjemov\u00fdch\u00bb armatur, statick\u00fdch \u010di dynamick\u00fdch, kter\u00e9 umo\u017e\u0148uj\u00ed m\u011b\u0159en\u00ed pr\u016ftok\u016f.<br \/>Nelze ji tedy pou\u017e\u00edt na <strong>neobjemov\u00e9 ventily<\/strong> jako jsou nap\u0159\u00edklad jednoduch\u00e9 regula\u010dn\u00ed ventily instalovan\u00e9 na v\u00fdstupu z radi\u00e1tor\u016f, ale tak\u00e9 na spodn\u00ed \u010d\u00e1sti stoupa\u010dek a p\u0159edev\u0161\u00edm na zp\u00e1te\u010dk\u00e1ch okruh\u016f podlahov\u00e9ho vyt\u00e1p\u011bn\u00ed.<\/p>\n<p>Je t\u0159eba tak\u00e9 p\u0159ipomenout, \u017ee n\u011bkter\u00e9 regula\u010dn\u00ed ventily pro diferen\u010dn\u00ed tlak nejsou objemov\u00e9. Jejich nastaven\u00ed nebo kontrola nastaven\u00ed se mus\u00ed prov\u00e1d\u011bt v\u00fdhradn\u011b m\u011b\u0159en\u00edm teplot v zp\u011btn\u00e9m potrub\u00ed.<\/p>\n<p>U st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00ed bude muset projek\u010dn\u00ed kancel\u00e1\u0159 za \u00fa\u010delem stanoven\u00ed pr\u016ftok\u016f, kter\u00e9 je t\u0159eba nastavit, prov\u00e9st m\u011b\u0159en\u00ed nezbytn\u00e1 k odhadu tepeln\u00fdch ztr\u00e1t u ka\u017ed\u00e9 z topn\u00fdch ant\u00e9n, kter\u00e9 maj\u00ed b\u00fdt upraveny.<br \/>K tomu bude muset vypo\u010d\u00edtat tepeln\u00e9 ztr\u00e1ty standardn\u00edch m\u00edstnost\u00ed i m\u00edstnost\u00ed zvl\u00e1\u0161tn\u00edho charakteru (pod terasou, u \u0161t\u00edtu atd.). Pot\u00e9, co\u017e b\u00fdv\u00e1 \u010dasto velmi slo\u017eit\u00e9, bude muset tyto ztr\u00e1ty spr\u00e1vn\u011b p\u0159i\u0159adit ke ka\u017ed\u00e9 z ant\u00e9n, kter\u00e9 m\u00e1 nastavit.<\/p>\n<p>Nastaven\u00ed pr\u016ftok\u016f vy\u017eaduje pou\u017eit\u00ed m\u011b\u0159ic\u00ed soupravy a, pokud se nejedn\u00e1 o dynamick\u00e9 ventily, tak\u00e9 pou\u017eit\u00ed speci\u00e1ln\u00ed metodiky.<br \/>Jednu z t\u011bchto metod si m\u016f\u017eete po\u0159\u00eddit na <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-debit.htm\" target=\"_blank\" rel=\"noopener noreferrer\">E-vzd\u011bl\u00e1v\u00e1n\u00ed Xpair<\/a> nebo na <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simul\u00e1tor.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Regulace pr\u016ftoku\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec10.jpg\" alt=\"\" width=\"551\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 9: Regulace pr\u016ftoku \u2013 zdroj <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> a m\u011b\u0159ic\u00ed kuf\u0159\u00edk <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Pokud jsou kohoutky, kter\u00e9 je t\u0159eba se\u0159\u00eddit,<strong> dynamick\u00e9ho typu <\/strong>Nastaven\u00ed pr\u016ftok\u016f lze prov\u00e9st snadn\u011bji, ani\u017e by bylo nutn\u00e9 pou\u017e\u00edt n\u011bjakou zvl\u00e1\u0161tn\u00ed metodu; sta\u010d\u00ed pouze ov\u011b\u0159it, zda m\u00e1 nejvzd\u00e1len\u011bj\u0161\u00ed kohoutek dostate\u010dn\u00fd diferen\u010dn\u00ed tlak v p\u0159\u00edvodu.<\/p>\n<p>U n\u011bkter\u00fdch dynamick\u00fdch ventil\u016f s odstup\u0148ovan\u00fdm pr\u016ftokem lze p\u0159ednastaven\u00ed prov\u00e9st bez m\u011b\u0159en\u00ed, to v\u0161ak nezbavuje povinnosti prov\u00e9st z\u00e1v\u011bre\u010dn\u00e9 m\u011b\u0159en\u00ed nam\u011b\u0159en\u00fdch pr\u016ftok\u016f pot\u00e9, co budou v\u0161echny ventily p\u0159ednastaveny.<br \/>U model\u016f bez stupnice pr\u016ftoku, zejm\u00e9na u ventil\u016f pro regulaci diferen\u010dn\u00edho tlaku, nelze pr\u016ftok nastavit bez jeho skute\u010dn\u00e9ho m\u011b\u0159en\u00ed (pokud se nav\u00edc jedn\u00e1 o objemov\u00e9 ventily).<\/p>\n<p>Jakmile budou v\u0161echny dynamick\u00e9 ventily nastaveny nebo p\u0159ednastaveny \u2013 pokud se jedn\u00e1 o objemov\u00e9 ventily \u2013, bude d\u016fkladn\u00e9 vyv\u00e1\u017een\u00ed zavr\u0161eno m\u011b\u0159en\u00edm v\u0161ech pr\u016ftok\u016f v okruhu, aby se zajistilo, \u017ee byly \u0159\u00e1dn\u011b vy\u0159e\u0161eny hydraulick\u00e9 interakce mezi jednotliv\u00fdmi v\u011btvemi.<br \/>Je t\u0159eba si uv\u011bdomit, \u017ee sta\u010d\u00ed jen n\u011bkolik znev\u00fdhodn\u011bn\u00fdch odbo\u010dek, aby bylo nutn\u00e9 p\u0159et\u00e1p\u011bt cel\u00fd zbytek rozvodu, a hydraulick\u00e9 chov\u00e1n\u00ed okruh\u016f, zejm\u00e9na t\u011bch st\u00e1vaj\u00edc\u00edch, \u010dasto skr\u00fdv\u00e1 nejedno p\u0159ekvapen\u00ed.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>3<sup>t\u00e9ma<\/sup> metoda: M\u011b\u0159en\u00ed a vyrovn\u00e1v\u00e1n\u00ed teplot zp\u011btn\u00e9ho toku vody b\u011bhem topn\u00e9 sez\u00f3ny<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Toto nov\u011bj\u0161\u00ed \u0159e\u0161en\u00ed, zn\u00e1m\u00e9 jako \u00abmetoda EQUILOG\u00bb, spo\u010d\u00edv\u00e1 v tom, \u017ee p\u0159i b\u011b\u017en\u00e9m provozu topn\u00e9ho syst\u00e9mu a stabilizovan\u00e9 teplot\u011b v odb\u011brn\u00edm okruhu se <strong>m\u011b\u0159it teploty zp\u011btn\u00e9 vody <\/strong>ant\u00e9ny je t\u0159eba vyv\u00e1\u017eit a sjednotit tak, aby v\u0161echny ant\u00e9ny, kter\u00e9 se maj\u00ed se\u0159izovat, m\u011bly stejnou \u00abteplotu\u00bb.<\/p>\n<p>Tento postup, kter\u00fd se na prvn\u00ed pohled jev\u00ed jako \u00abzjednodu\u0161uj\u00edc\u00ed\u00bb, byl a st\u00e1le je p\u0159edm\u011btem zcela p\u0159irozen\u00fdch kritik ze strany konkurence. K tomuto t\u00e9matu si m\u016f\u017eete p\u0159e\u010d\u00edst <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-hydraulique-methode-simple.htm\" target=\"_blank\" rel=\"noopener\">\u00abHydraulick\u00e9 vyva\u017eov\u00e1n\u00ed: novinky t\u00fdkaj\u00edc\u00ed se jednoduch\u00e9 metody\u00bb. <\/a>Je v\u0161ak z\u0159ejm\u00e9, \u017ee na n\u011bkolika stech lokalit\u00e1ch bylo dosud t\u00edmto zp\u016fsobem za dobr\u00fdch podm\u00ednek z hlediska rentability zpracov\u00e1no v\u00edce ne\u017e 80 000 ekvivalent\u016f byt\u016f.<\/p>\n<p>Po vyv\u00e1\u017een\u00ed budou ant\u00e9ny vykazovat srovnateln\u00e9 teploty na zp\u011btn\u00e9m veden\u00ed a srovnateln\u00e9 teplotn\u00ed rozd\u00edly mezi p\u0159\u00edvodem a zp\u011btn\u00fdm veden\u00edm <em>(*)<\/em>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Sjednocen\u00ed teplot vody v topn\u00e9m okruhu\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec12.gif\" alt=\"\" width=\"573\" height=\"229\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 11: Vyrovn\u00e1n\u00ed(*) teplot vody v topn\u00e9m okruhu<\/em><\/p>\n<p class=\"text-justify push-top\"><em>(*) Pokud to rozvod vody umo\u017e\u0148uje, je samoz\u0159ejm\u011b mo\u017en\u00e9 nastavit na ka\u017ed\u00e9m odbo\u010dkov\u00e9m bod\u011b odli\u0161nou teplotu vody, aby se zohlednily m\u00edstn\u00ed izola\u010dn\u00ed opat\u0159en\u00ed. <\/em><br \/><em>Zjistilo se v\u0161ak, \u017ee u budov, u nich\u017e byla provedena komplexn\u00ed tepeln\u00e1 renovace (v\u00fdm\u011bna v\u0161ech oken a dve\u0159\u00ed, zateplen\u00ed v\u0161ech vn\u011bj\u0161\u00edch svisl\u00fdch st\u011bn), vyv\u00e1\u017een\u00ed <u>po\u010d\u00e1te\u010dn\u00ed nebo n\u00e1sledn\u00fd<\/u> K dosa\u017een\u00ed dobr\u00e9ho v\u00fdsledku sta\u010d\u00ed vyrovnat teplotu vody. <\/em><br \/><em>N\u00e1sledn\u011b lze v\u00fdkon topen\u00ed upravit jednoduch\u00fdm nastaven\u00edm teploty vody na v\u00fdstupu z kotelny (nastaven\u00ed topn\u00e9ho profilu).<\/em><\/p>\n<p>Tento postup, kter\u00fd lze pou\u017e\u00edt u v\u0161ech typ\u016f kohoutk\u016f, se poda\u0159ilo optimalizovat d\u00edky pokroku v oblasti infra\u010derven\u00e9 termometrie a v\u00fdzkumu proveden\u00e9mu institutem GMTI94 \u2013 GEFEn.<br \/>Jeho princip lze prozkoumat na <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-temp.htm\" target=\"_blank\" rel=\"noopener noreferrer\">E-vzd\u011bl\u00e1v\u00e1n\u00ed Xpair<\/a> nebo na <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simul\u00e1tor<\/a>.<\/p>\n<p>Hlavn\u00ed v\u00fdhodou t\u00e9to metodiky je, \u017ee u s\u00edt\u00ed s b\u011b\u017en\u00fdm dimenzov\u00e1n\u00edm nen\u00ed nutn\u00e9 prov\u00e1d\u011bt \u017e\u00e1dn\u00e9 v\u00fdpo\u010dty ztr\u00e1t ani m\u011b\u0159en\u00ed instalace. Je proto obzvl\u00e1\u0161t\u011b vhodn\u00e1 pro st\u00e1vaj\u00edc\u00ed okruhy, u nich\u017e jsou archivn\u00ed \u00fadaje k dispozici jen z\u0159\u00eddka.<\/p>\n<p>Tento postup, kter\u00fd byl experiment\u00e1ln\u011b zaveden v roce 2000, byl patentov\u00e1n ve Francii a ned\u00e1vno tak\u00e9 v 15 evropsk\u00fdch zem\u00edch.<br \/>Metodu \u00abEQUILOG\u00bb uplat\u0148uje zejm\u00e9na <em>\u00ab <\/em><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><em>spole\u010dnost MAPSEC <\/em><\/strong><\/a><em>\u00bb(*) <\/em>pro r\u016fzn\u00e9 provozn\u00ed a instala\u010dn\u00ed spole\u010dnosti (Dalkia, Cofely-Soccram, Idex atd.).<br \/><em>(*) MAPSEC, 80 rue de Paris, 93100 Montreuil, tel.: 01 48 59 06 05 \u2013 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr<\/a><\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Ob\u011bhov\u00e9 \u010derpadlo\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec11.jpg\" alt=\"\" width=\"250\" height=\"187\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr\u00e1zek \u010d. 10: Regulace teploty vody \u2013 Zdroj <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/\" target=\"_blank\" rel=\"noopener noreferrer\">Mapsec<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Na z\u00e1v\u011br je t\u0159eba poznamenat, \u017ee v <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u010dl\u00e1nek v\u011bnovan\u00fd dynamick\u00fdm vyva\u017eovac\u00edm ventil\u016fm<\/a> Jak bylo zm\u00edn\u011bno v p\u0159edchoz\u00edm odstavci, in\u017een\u00fdr zastupuj\u00edc\u00ed spole\u010dnost Oventrop to uv\u00e1d\u00ed v pozn\u00e1mk\u00e1ch na konci spisu.<br \/><em>\u00abU st\u00e1vaj\u00edc\u00edch syst\u00e9m\u016f je podle m\u00e9ho n\u00e1zoru vyva\u017eov\u00e1n\u00ed prost\u0159ednictv\u00edm sjednocen\u00ed teplot v zp\u011btn\u00e9m potrub\u00ed rovn\u011b\u017e nejlep\u0161\u00ed metodou, pokud je zvolen spr\u00e1vn\u00fd teplotn\u00ed pokles.\u201c.<br \/>P\u0159esto je tato metoda \u010dasov\u011b n\u00e1ro\u010dn\u00e1 a instala\u010dn\u00ed technici specializuj\u00edc\u00ed se na bytovou v\u00fdstavbu ji jen t\u011b\u017eko akceptuj\u00ed, pokud ji je t\u0159eba prov\u00e1d\u011bt ru\u010dn\u011b.<br \/>\u00bbExistuj\u00ed kohoutky, kter\u00e9 to d\u011blaj\u00ed automaticky, ale cena je jin\u00e1.\u201c<\/em><\/p>\n<p>Je pravda, \u017ee vyva\u017eov\u00e1n\u00ed prost\u0159ednictv\u00edm vyrovn\u00e1n\u00ed teplot v zp\u011btn\u00e9m okruhu d\u0159\u00edve vy\u017eadovalo dlouh\u00e9 \u010dekac\u00ed doby na tepeln\u00e9 ust\u00e1len\u00ed, av\u0161ak d\u00edky nejnov\u011bj\u0161\u00edm pokrok\u016fm se dnes ji\u017e lze t\u011bchto \u010dekac\u00edch dob zbavit a doba trv\u00e1n\u00ed operac\u00ed se stala velmi konkurenceschopnou.<\/p>\n<p>Krom\u011b toho by se skute\u010dn\u011b dalo uva\u017eovat o automatick\u00e9m dosa\u017een\u00ed a dlouhodob\u00e9m udr\u017eov\u00e1n\u00ed vyv\u00e1\u017eenosti prost\u0159ednictv\u00edm sjednocen\u00ed teplot v zp\u011btn\u00e9m veden\u00ed. V sou\u010dasn\u00e9m stavu technologie by to v\u0161ak vy\u017eadovalo instalaci a nap\u00e1jen\u00ed automatick\u00fdch motorizovan\u00fdch vyva\u017eovac\u00edch ventil\u016f, kter\u00e9 by byly p\u0159ipojeny k \u0159\u00eddic\u00edmu automatu nebo k syst\u00e9mu \u0159\u00edzen\u00ed technick\u00fdch za\u0159\u00edzen\u00ed budov (TZB).<br \/>Z ekonomick\u00e9ho hlediska je to prozat\u00edm t\u011b\u017eko p\u0159edstaviteln\u00e9, alespo\u0148 u st\u00e1vaj\u00edc\u00edch za\u0159\u00edzen\u00ed.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANAL\u00ddZA A ODBORN\u00c9 ZNALOSTI INSTALAT\u00c9R\u016e<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Je t\u0159eba zejm\u00e9na jasn\u011b rozli\u0161ovat mezi odkalov\u00e1n\u00edm (je-li to nutn\u00e9) a instalac\u00ed vyrovn\u00e1vac\u00edch ventil\u016f na jedn\u00e9 stran\u011b a jejich samotn\u00fdm po\u010d\u00e1te\u010dn\u00edm se\u0159\u00edzen\u00edm na stran\u011b druh\u00e9.<\/p>\n<p>A\u0165 u\u017e se jedn\u00e1 o jak\u00fdkoli typ armatury, je pro instala\u010dn\u00ed nebo odv\u00e1p\u0148ovac\u00ed firmu l\u00e1kav\u00e9 zahrnout do sv\u00e9 nab\u00eddky polo\u017eku \u201euveden\u00ed do provozu\u201c, ani\u017e by v\u017edy byla schopna definovat v\u0161echny parametry.<\/p>\n<p>Samoz\u0159ejm\u011b si lze p\u0159edstavit, \u017ee by celou operaci vyva\u017eov\u00e1n\u00ed mohla zajistit jedna jedin\u00e1 spole\u010dnost, ale v takov\u00e9m p\u0159\u00edpad\u011b mus\u00ed disponovat t\u00fdmy s velmi rozmanit\u00fdmi praktick\u00fdmi i teoretick\u00fdmi znalostmi.<\/p>\n<p>Obecn\u011b je tedy t\u0159eba postupovat p\u0159i v\u00fdb\u011bru firmy, kter\u00e1 m\u00e1 prov\u00e9st vyva\u017eov\u00e1n\u00ed, s maxim\u00e1ln\u00ed opatrnost\u00ed. Jedn\u00e1 se o n\u00e1ro\u010dnou technickou specializaci a p\u0159\u00edpad\u016f neuspokojiv\u00fdch v\u00fdsledk\u016f je mnoho, proto\u017ee je obt\u00ed\u017en\u00e9 ov\u011b\u0159it kvalitu proveden\u00e9 pr\u00e1ce.<\/p>\n<p>I kdyby to m\u011blo znamenat dodate\u010dn\u00e9 n\u00e1klady, nebudeme tedy v\u00e1hat rozd\u011blit jednotliv\u00e9 \u010dinnosti tak, aby f\u00e1ze studie a\/nebo v\u00fdvoje zaji\u0161\u0165ovali odborn\u00edci v dan\u00e9 oblasti.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radi\u00e1tor\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec13.jpg\" alt=\"\" width=\"450\" height=\"173\" \/><\/p>\n<p class=\"text-justify push-top\">Dobr\u00fdm zp\u016fsobem, jak si vybrat, je zeptat se p\u0159i konzultaci, jak\u00fd typ metody bude pou\u017eit, a nechat si p\u0159esn\u011b vysv\u011btlit, jak\u00e9 \u00fadaje budou po operaci poskytnuty.<br \/>Jak\u00e1koli nejasnost nebo v\u00e1h\u00e1n\u00ed v odpov\u011bd\u00edch na n\u011bkter\u00fd z t\u011bchto dvou bod\u016f bude nepochybn\u011b znamen\u00edm nedostate\u010dn\u00e9 p\u0159ipravenosti.<\/p>\n<p>Pokud spole\u010dnost pracuje na z\u00e1klad\u011b m\u011b\u0159en\u00ed pr\u016ftoku nebo hydraulick\u00e9 simulace, lze po\u017eadovat, aby nab\u00eddka obsahovala kone\u010dnou slevu:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Podrobn\u00fd v\u00fdpo\u010det tepeln\u00fdch ztr\u00e1t <strong>v souladu s ka\u017ed\u00fdm kohoutkem, kter\u00fd m\u00e1 b\u00fdt upraven<\/strong> a kter\u00e9 vedly ke stanoven\u00ed pr\u016ftok\u016f, kter\u00e9 je t\u0159eba regulovat. T\u00edmto zp\u016fsobem bude mo\u017en\u00e9 zajistit, \u017ee stanoven\u00e9 pr\u016ftoky nejsou v\u00fdsledkem hrub\u00fdch odhad\u016f.<\/li>\n<li class=\"pad5\">Z m\u0159\u00ed\u017eky <strong>certifikovan\u00e1<\/strong> nam\u011b\u0159en\u00e9 pr\u016ftoky <u>po uzav\u0159en\u00ed v\u0161ech kohoutk\u016f<\/u> (a nespokojit se pouze s tabulkou teoreticky p\u0159edpokl\u00e1dan\u00fdch pr\u016ftok\u016f). T\u00edmto zp\u016fsobem bude mo\u017en\u00e9 zajistit, \u017ee hydraulick\u00e9 interakce mezi ant\u00e9nami, kter\u00e9 maj\u00ed b\u00fdt nastaveny, byly skute\u010dn\u011b zohledn\u011bny, a v p\u0159\u00edpad\u011b pot\u0159eby to i ov\u011b\u0159it.<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Pokud spole\u010dnost pracuje na z\u00e1klad\u011b m\u011b\u0159en\u00ed teplot v zp\u011btn\u00e9m potrub\u00ed, lze po\u017eadovat, aby n\u00e1vrh obsahoval:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">N\u011bkolik p\u0159\u00edslu\u0161n\u00fdch referenc\u00ed, nebo l\u00e9pe \u0159e\u010deno, p\u0159edlo\u017een\u00ed alespo\u0148 jedn\u00e9 podrobn\u00e9 zpr\u00e1vy o d\u0159\u00edve proveden\u00e9 operaci. Takto bude mo\u017en\u00e9 ov\u011b\u0159it zku\u0161enosti uchaze\u010de, nebo\u0165 a\u010dkoli je princip t\u00e9to metody zn\u00e1m ji\u017e dlouho, teprve ned\u00e1vno se poda\u0159ilo dos\u00e1hnout jej\u00edho dokonal\u00e9ho zvl\u00e1dnut\u00ed.<\/li>\n<li class=\"pad5\">Zobrazen\u00ed grafu <strong>ov\u011b\u0159en\u00fd, \u00fapln\u00fd a podrobn\u00fd<\/strong> nam\u011b\u0159en\u00e9 teploty v zp\u011btn\u00e9m potrub\u00ed,<strong> p\u0159ed a po vyv\u00e1\u017een\u00ed<\/strong>, s uveden\u00edm ust\u00e1len\u00fdch v\u00fdstupn\u00edch teplot, p\u0159i kter\u00fdch byly tyto m\u011b\u0159en\u00ed provedeny. T\u00edmto zp\u016fsobem bude mo\u017en\u00e9 ov\u011b\u0159it kvalitu proveden\u00e9 pr\u00e1ce.<\/li>\n<\/ul>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ZISKOVOST A \u00daSPORY ENERGIE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Nen\u00ed snadn\u00e9 odhadnout, jak\u00e9 \u00faspory energie lze od vyv\u00e1\u017een\u00ed o\u010dek\u00e1vat.<br \/>Vskutku, i kdy\u017e by se v p\u0159\u00edpad\u011b dokonale proveden\u00e9ho vyrovn\u00e1n\u00ed dalo odhadnout na z\u00e1klad\u011b mapy po\u010d\u00e1te\u010dn\u00edch teplot v m\u00edstnosti, ve skute\u010dnosti je velmi obt\u00ed\u017en\u00e9 tuto mapu interpretovat.<br \/>V ka\u017ed\u00e9m p\u0159\u00edpad\u011b, pokud se rozhodneme pro tento zp\u016fsob odhadu, je t\u0159eba vych\u00e1zet ze z\u00e1znam\u016f po\u0159\u00edzen\u00fdch v obdob\u00ed s velmi n\u00edzk\u00fdmi teplotami a bez jak\u00e9hokoli bezplatn\u00e9ho p\u0159\u00edkonu (slune\u010dn\u00ed z\u00e1\u0159en\u00ed, elektrick\u00e1 za\u0159\u00edzen\u00ed atd.), a nikoli z okam\u017eit\u00fdch m\u011b\u0159en\u00ed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"P\u0159\u00edklad z\u00e1znamu teplot v m\u00edstnosti ovlivn\u011bn\u00fdch bezplatn\u00fdmi dod\u00e1vkami\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec15.jpg\" alt=\"\" width=\"400\" height=\"235\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Obr. 15: P\u0159\u00edklad z\u00e1znamu teplot v m\u00edstnosti ovlivn\u011bn\u00fdch bezplatn\u00fdmi dod\u00e1vkami<\/em><\/p>\n<p class=\"text-justify push-top\">Je\u0161t\u011b slo\u017eit\u011bj\u0161\u00ed je v\u0161ak zohledn\u011bn\u00ed um\u00edst\u011bn\u00ed vyva\u017eovac\u00edch ventil\u016f, kter\u00e9 bude mo\u017en\u00e9 skute\u010dn\u011b nastavit. Ve st\u00e1vaj\u00edc\u00edch topn\u00fdch soustav\u00e1ch se toti\u017e vyva\u017eov\u00e1n\u00ed obvykle prov\u00e1d\u00ed pouze na ventilech, kter\u00e9 jsou p\u0159\u00edstupn\u00e9 z 2.<sup>t\u00e9ma<\/sup> \u00farove\u0148 (viz 2<sup>t\u00e9ma<\/sup> \u00a7). V d\u016fsledku toho je v\u00edce \u010di m\u00e9n\u011b \u00fasp\u011b\u0161n\u00e9 zaveden\u00ed tohoto 2<sup>t\u00e9ma<\/sup> \u00darove\u0148 je kl\u00ed\u010dov\u00fdm parametrem pro odhad o\u010dek\u00e1van\u00e9 \u00faspory energie.<\/p>\n<p>V tomto ohledu spole\u010dnost MAPSEC pou\u017e\u00edv\u00e1 metodiku zn\u00e1mou jako <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/ecomapsec\/\" target=\"_blank\" rel=\"noopener noreferrer\">REQUILOG<\/a> kter\u00e1 mu umo\u017e\u0148uje na z\u00e1klad\u011b mapy teplot zp\u011btn\u00e9 vody nam\u011b\u0159en\u00fdch ve v\u00fd\u0161ce kohoutk\u016f, u nich\u017e m\u00e1 prov\u00e9st se\u0159\u00edzen\u00ed, vyhodnotit rozsah nerovnov\u00e1hy, kterou bude mo\u017en\u00e9 skute\u010dn\u011b odstranit.<br \/>Proto, je-li to mo\u017en\u00e9, p\u0159ed vyva\u017eovac\u00edmi operacemi, kter\u00e9 jsou mu sv\u011b\u0159eny, prob\u011bhne diagnostick\u00fd postup zahrnuj\u00edc\u00ed toto posouzen\u00ed, co\u017e umo\u017e\u0148uje osob\u011b s rozhodovac\u00ed pravomoc\u00ed l\u00e9pe posoudit, zda je vhodn\u00e9 danou operaci prov\u00e9st, \u010di nikoli.<\/p>\n<p>Na z\u00e1v\u011br je t\u0159eba poznamenat, \u017ee \u00faspora energie vypl\u00fdvaj\u00edc\u00ed z vyv\u00e1\u017een\u00ed bude vy\u017eadovat n\u00e1sledn\u00fd z\u00e1sah technika pov\u011b\u0159en\u00e9ho nastaven\u00edm regula\u010dn\u00edho syst\u00e9mu.<br \/>Kdyby toti\u017e vyva\u017eov\u00e1n\u00ed m\u011blo nakonec spo\u010d\u00edvat v tom, \u017ee by se prostory, kter\u00e9 byly p\u016fvodn\u011b nejh\u016f\u0159e vyt\u00e1p\u011bn\u00e9, dostaly na \u00farove\u0148 t\u011bch nejl\u00e9pe vyt\u00e1p\u011bn\u00fdch, nedos\u00e1hli bychom t\u00edm \u017e\u00e1dn\u00e9 \u00faspory energie\u2026<\/p>\n<p>Celkov\u011b se zd\u00e1, \u017ee pr\u016fm\u011brn\u00e1 \u00faspora energie % po vyv\u00e1\u017een\u00ed rozvodu topen\u00ed se pohybuje kolem 7%, p\u0159i\u010dem\u017e n\u00e1vratnost investice je p\u0159ibli\u017en\u011b 2 a\u017e 3 roky, pokud okruh nevy\u017eaduje \u017e\u00e1dnou nebo jen minim\u00e1ln\u00ed v\u00fdm\u011bnu ventil\u016f.<\/p>\n<p>A\u017e do prosince 2014 bylo mo\u017en\u00e9 tyto operace zahrnout do syst\u00e9mu certifik\u00e1t\u016f \u00faspory energie s pau\u0161\u00e1ln\u00ed sazbou \u00faspory energie ve v\u00fd\u0161i 10%.<br \/>P\u0159\u00edslu\u0161n\u00e9 p\u0159edpisy BAR a BAT SE 04 se v sou\u010dasn\u00e9 dob\u011b upravuj\u00ed. M\u011bly by b\u00fdt znovu zve\u0159ejn\u011bny pod jin\u00fdmi n\u00e1zvy v p\u0159\u00ed\u0161t\u00edm ministersk\u00e9m na\u0159\u00edzen\u00ed v\u011bnovan\u00e9m CEE.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"tla\u010d\u00edtko ECO\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec14.jpg\" alt=\"\" width=\"250\" height=\"180\" \/><\/p>\n<p class=\"text-justify push-top\">Na z\u00e1v\u011br lze s jistotou \u0159\u00edci, \u017ee vyva\u017eovac\u00ed operace jsou celkov\u011b naprosto rentabiln\u00ed, pokud se prov\u00e1d\u011bj\u00ed d\u016fsledn\u011b.<\/p>\n<p>Nejlep\u0161\u00edm d\u016fkazem toho je pr\u00e1ce vykonan\u00e1 vyva\u017eovac\u00edm odd\u011blen\u00edm spole\u010dnosti Dalkia v regionu \u00cele-de-France(*), kter\u00e9 bylo zalo\u017eeno p\u0159ed zhruba deseti lety za \u00fa\u010delem vyu\u017e\u00edv\u00e1n\u00ed metody EQUILOG a kter\u00e9 v sou\u010dasn\u00e9 dob\u011b vede pan Christophe Tillay.<br \/>Na webu Xpair si m\u016f\u017eete p\u0159e\u010d\u00edst zpr\u00e1vu o jednom z jeho projekt\u016f v \u010dl\u00e1nku <a class=\"bleu\" href=\"http:\/\/conseils.xpair.com\/actualite_experts\/exemple-operation-equilibrage-egalisation-temperatures-retour.htm\" target=\"_blank\" rel=\"noopener noreferrer\">\u00abRegula\u010dn\u00ed z\u00e1sah spo\u010d\u00edvaj\u00edc\u00ed ve vyrovn\u00e1n\u00ed teplot v zp\u011btn\u00e9m okruhu\u00bb.<\/a><\/p>\n<p><em>(*) Dalkia Ile-de-France, odd\u011blen\u00ed vyva\u017eov\u00e1n\u00ed, 28 Boulevard de Pesaro, 92 751 NANTERRE CEDEX Tel.: 01 55 67 68 97 <\/em><\/p>\n<p>Stovky vyrovn\u00e1vac\u00edch operac\u00ed proveden\u00fdch touto slu\u017ebou se t\u00fdkaly v\u00fdhradn\u011b nemovitostn\u00edch komplex\u016f spravovan\u00fdch spole\u010dnost\u00ed v r\u00e1mci smluv typu MF (pau\u0161\u00e1ln\u00ed smlouva) nebo MT (smlouva o teplot\u011b). U tohoto typu smluv, kter\u00e9 nejsou p\u0159\u00edli\u0161 roz\u0161\u00ed\u0159en\u00e9, hrad\u00ed z\u00e1kazn\u00edk provozovateli ka\u017edoro\u010dn\u011b pau\u0161\u00e1ln\u00ed \u010d\u00e1stku (nebo \u010d\u00e1stku upravenou o DJU) v\u00fdm\u011bnou za z\u00e1ruku optim\u00e1ln\u00edho vyt\u00e1p\u011bn\u00ed.<\/p>\n<p>Zaji\u0161t\u011bn\u00ed paliva je tedy pln\u011b v kompetenci provozn\u00ed spole\u010dnosti. Jej\u00ed hlavn\u00ed z\u00e1jem proto spo\u010d\u00edv\u00e1 v tom, aby spot\u0159ebu paliva sn\u00ed\u017eila v r\u00e1mci zaji\u0161t\u011bn\u00ed dostate\u010dn\u00e9ho vyt\u00e1p\u011bn\u00ed pro z\u00e1kazn\u00edka, proto\u017ee ve\u0161ker\u00e9 dosa\u017een\u00e9 \u00faspory energie p\u0159ipadnou pr\u00e1v\u011b j\u00ed.<\/p>\n<p>Tento typ zak\u00e1zky samoz\u0159ejm\u011b motivuje dodavatele k co nejlep\u0161\u00edmu \u0159\u00edzen\u00ed provozu za\u0159\u00edzen\u00ed a k nasazen\u00ed sv\u00fdch nejlep\u0161\u00edch t\u00fdm\u016f. Z ekologick\u00e9ho hlediska je tak situace optim\u00e1ln\u00ed.<br \/>Z\u00e1kazn\u00edk m\u00e1 p\u0159itom bez jak\u00fdchkoli zvl\u00e1\u0161tn\u00edch dodate\u010dn\u00fdch n\u00e1klad\u016f z\u00e1ruku trval\u00e9ho a spr\u00e1vn\u011b nastaven\u00e9ho vyt\u00e1p\u011bn\u00ed a tak\u00e9 jistotu, \u017ee po skon\u010den\u00ed smluv, kter\u00e9 obvykle trvaj\u00ed 8 let, p\u0159evezme za\u0159\u00edzen\u00ed v co nejlep\u0161\u00ed technick\u00e9 kondici.<\/p>\n<p>Vyva\u017eov\u00e1n\u00ed proveden\u00e9 odd\u011blen\u00edm pro vyva\u017eov\u00e1n\u00ed spole\u010dnosti Dalkia IdF bylo tedy financov\u00e1no z vlastn\u00edch prost\u0159edk\u016f a d\u00edky dosa\u017een\u00fdm \u00faspor\u00e1m energie se investice amortizovala b\u011bhem n\u011bkolika let.<br \/>To, \u017ee se tato slu\u017eba udr\u017euje a rozv\u00edj\u00ed ji\u017e 10 let, je nepopirateln\u00fdm d\u016fkazem dobr\u00e9 rentability tohoto typu operac\u00ed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Graf vyva\u017eov\u00e1n\u00ed\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec16.jpg\" alt=\"\" width=\"400\" height=\"250\" \/><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\" style=\"text-align: left;\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>Z\u00c1V\u011aR<\/h2>\n<\/div>\n<p class=\"text-justify push-top\" style=\"text-align: left;\">Sn\u00ed\u017een\u00ed energetick\u00e9 spot\u0159eby na\u0161eho st\u00e1vaj\u00edc\u00edho syst\u00e9mu kolektivn\u00edho vyt\u00e1p\u011bn\u00ed spo\u010d\u00edv\u00e1 v izolaci, spr\u00e1vn\u00e9m nastaven\u00ed spalov\u00e1n\u00ed, regulaci a vyv\u00e1\u017een\u00ed.<\/p>\n<p style=\"text-align: left;\">Navzdory sv\u00e9mu z\u00e1sadn\u00edmu vlivu na nastaven\u00ed regulace a \u00fa\u010dinnost kondenza\u010dn\u00edch kotl\u016f (a kogenera\u010dn\u00edch jednotek) byl tento posledn\u00ed prvek dosud slab\u00fdm \u010dl\u00e1nkem.<\/p>\n<p style=\"text-align: left;\">Po velmi dlouh\u00e9 p\u0159est\u00e1vce je tento probl\u00e9m aktu\u00e1ln\u011bj\u0161\u00ed ne\u017e kdy jindy.<\/p>\n<p style=\"text-align: left;\">Ned\u00e1vn\u00e9 pokroky v oblasti armatur a technick\u00e9ho v\u00fdvoje by m\u011bly umo\u017enit lep\u0161\u00ed vyu\u017eit\u00ed jednoho z nejv\u00fdznamn\u011bj\u0161\u00edch dosud dostupn\u00fdch zdroj\u016f \u00faspor energie.<\/p>\n<\/div>\n<h4 class=\"text-primary push-top\" style=\"text-align: left;\"><strong>ZDROJE A ODKAZY<\/strong><\/h4>\n<ul class=\"push-top\">\n<li class=\"pad10\" style=\"text-align: left;\">UP\u0158ESN\u011aN\u00cd: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/upresneni\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mise-au-point<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">UVEDEN\u00cd DO PROVOZU SYST\u00c9M\u016e VENTILACE A KLIMATIZACE: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/uvedeni-do-provozu\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/commissioning<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">AUDIT V TER\u00c9NU: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/audit\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/audit<\/a><\/li>\n<li style=\"text-align: left;\">TEST T\u011aSNOSTI Vzduchotechnick\u00e9 s\u00edt\u011b:\u00a0<a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mesure-de-letancheite-a-lair-des-reseaux-aeraulique<\/a><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/cs\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">s<\/a><\/li>\n<li style=\"text-align: left;\">SIMUL\u00c1TOR Nau\u010dte se vyva\u017eov\u00e1n\u00ed: <a href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564\" target=\"_blank\" rel=\"noopener\">www.edipa.fr\/LibrairieTechnique\/Details\/564<\/a><\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Par Patrick DELPECH &#8211; pour la soci\u00e9t\u00e9 MAPSEC &#8211; Mars 2020 Pour les responsables techniques et d\u00e9cideurs (maitres d\u2019ouvrage, syndic, etc.), les nouveaut\u00e9s du secteur, les<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16263","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/posts\/16263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/comments?post=16263"}],"version-history":[{"count":4,"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/posts\/16263\/revisions"}],"predecessor-version":[{"id":17284,"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/posts\/16263\/revisions\/17284"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/media?parent=16263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/categories?post=16263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/cs\/wp-json\/wp\/v2\/tags?post=16263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}