{"id":16263,"date":"2015-09-01T17:36:27","date_gmt":"2015-09-01T16:36:27","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16263"},"modified":"2026-06-29T16:46:06","modified_gmt":"2026-06-29T14:46:06","slug":"alt-om-automatisk-statisk-hydraulisk-afbalancering","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/da\/2015\/09\/01\/tout-sur-lequilibrage-hydraulique-statiqueautomatique\/","title":{"rendered":"Alt om statisk og automatisk hydraulisk afbalancering"},"content":{"rendered":"<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/mapsec.fr\/da\/kontakt\/\" style=\"border-radius:2px\">anmode om et tilbud <\/a><\/div>\n<\/div>\n\n\n<p class=\"text-right small\" style=\"text-align: right;\">Af Patrick DELPECH \u2013 p\u00e5 vegne af firmaet MAPSEC \u2013 marts 2020<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><em>For tekniske ansvarlige og beslutningstagere (bygherrer, ejendomsadministratorer osv.): de nyeste udviklinger i branchen, de faldgruber, man b\u00f8r undg\u00e5, og betingelserne for en korrekt udf\u00f8relse af hydrauliske og termiske afbalanceringer.<\/em><\/p>\n<p>Denne side beskriver de generelle principper for statisk og automatisk hydraulisk afbalancering.<\/p>\n<p>Hvis du vil l\u00e6re mere om MAPSEC-metoden anvendt p\u00e5 fjernvarmenet \u2013 herunder diagnose, m\u00e5linger, justeringer, validering og EQUILOG-metoden \u2013 kan du bes\u00f8ge vores hovedside om\u2019<a href=\"https:\/\/mapsec.fr\/da\/2016\/01\/13\/hydraulisk-afbalancering-af-varmeanlaeg-gratis-diagnose\/\">hydraulisk afbalancering af f\u00e6llesvarmeanl\u00e6g<\/a>.<\/p>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>PROBLEMSTILLINGEN<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">N\u00e5r der p\u00e5 et og samme varmekredsl\u00f8b samtidig findes rum, der er for varme, og rum, der er for koldt opvarmede, er dette et tegn p\u00e5 den meget udbredte ubalance i systemet.<br \/>Uanset den egentlige \u00e5rsag \u2013 forkert hydraulisk indstilling, dimensioneringsfejl, uensartet isolering osv. \u2013 kan problemet afhj\u00e6lpes ved at justere de s\u00e5kaldte udligningsventiler, forudsat at disse er korrekt fordelt og tilstr\u00e6kkeligt tilg\u00e6ngelige.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Justerings-T-stykke og volumetrisk ventil\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec1.jpg\" alt=\"\" width=\"529\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 1: Justerings-T-stykke og volumetrisk ventil <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Den n\u00f8dvendige justering best\u00e5r i at regulere ventilerne p\u00e5 de fordelte antenner p\u00e5 en s\u00e5dan m\u00e5de, at n\u00e5r deres gennemstr\u00f8mning mindskes, \u00f8ges gennemstr\u00f8mningen p\u00e5 de ufordelte antenner.<\/p>\n<p>Reguleringsprincippet er alts\u00e5 let at forst\u00e5, men det er langt sv\u00e6rere at s\u00e6tte det i praksis. I denne artikel beskrives det, under hvilke betingelser en hydraulisk afbalancering vil forl\u00f8be korrekt, is\u00e6r p\u00e5 eksisterende anl\u00e6g.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>PROJEKTKONTORERNES ANALYSE OG FAGLIGE KOMPETENCE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Generelt g\u00e6lder det, at et vandforsyningssystem til opvarmning <strong>eksisterende<\/strong> kan kun let afbalanceres, hvis der er monteret afbalanceringsventiler <u>tilg\u00e6ngelige<\/u>, uden for de benyttede lokaler.<br \/>Hvis anl\u00e6gget ikke er alt for gammelt, har projekteringsfirmaerne normalt taget h\u00f8jde for dette ved udformningen af anl\u00e6gget ved at installere s\u00e5kaldte 2-ventiler<sup>\u00e8me<\/sup> udligningsrum, der er placeret i k\u00e6ldre, krybek\u00e6ldre eller endda trappeopgange, og under alle omst\u00e6ndigheder uden for de beboede lokaler.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"2. trin-udligningsventiler \" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec2.jpg\" alt=\"\" width=\"650\" height=\"357\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 2: 2-vejs-haner<sup>\u00e8me<\/sup> afbalanceringsniveau<\/em><\/p>\n<p class=\"text-justify push-top\">Kredsl\u00f8b, hvor der kun er monteret reguleringsventiler p\u00e5 radiatorerne, er vanskelige at afbalancere, da det er meget sv\u00e6rt at sikre adgang til alle lokaler p\u00e5 samme tid, hvis de er i brug.<\/p>\n<p>I denne situation b\u00f8r man f\u00e5 et ingeni\u00f8rbureau eller en ekspert i trykudligning til at unders\u00f8ge fordelingssystemet for at fastsl\u00e5 mulighederne for installation af tilg\u00e6ngelige ventiler p\u00e5 2<sup>\u00e8me<\/sup> niveau.<br \/>Det skal bem\u00e6rkes, at afbalanceringen af kredsl\u00f8bet vil v\u00e6re desto mere effektiv, jo flere sendere der \u00abstyres\u00bb af 2-ventilerne<sup>\u00e8me<\/sup> Niveauet vil v\u00e6re moderat med et optimalt antal p\u00e5 5 til 10 enheder.<\/p>\n<p>Som hovedregel g\u00e6lder det for eksisterende anl\u00e6g, at den eneste indstilling af 2<sup>\u00e8me<\/sup> Justeringsniveauet (og de h\u00f8jere niveauer) er tilstr\u00e6kkeligt til at opn\u00e5 et korrekt resultat. Skulle der alligevel fortsat v\u00e6re uregelm\u00e6ssigheder p\u00e5 enkelte antenner, vil det altid v\u00e6re muligt at foretage en supplerende afbalancering p\u00e5 stedet. Dette kan udf\u00f8res korrekt, da den p\u00e5g\u00e6ldende gruppe af sendere p\u00e5 forh\u00e5nd vil v\u00e6re blevet forsynet normalt takket v\u00e6re den korrekte indstilling af dens 2-ventil.<sup>\u00e8me<\/sup> niveau.<\/p>\n<p>Hvis der installeres 2-vejs udligningsventiler<sup>\u00e8me<\/sup> Hvis dette niveau ikke kan realiseres, bliver man n\u00f8dt til at overveje en kompliceret adgangsplan til alle lokaler.<br \/>N\u00e5r vi nu alligevel v\u00e6lger denne kostbare l\u00f8sning, kan vi benytte lejligheden til at unders\u00f8ge muligheden for at installere den nyeste generation af termostatventiler, som desuden kan sikre en \u00abdynamisk\u00bb afbalancering, hvis fordele vi vil unders\u00f8ge n\u00e6rmere p\u00e5 et senere tidspunkt.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Hydraulisk dynamiske termostatventiler fra Danfoss\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec3.jpg\" alt=\"\" width=\"300\" height=\"251\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 3: Hydraulisk dynamiske termostatventiler <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Endelig skal det bem\u00e6rkes, at indstillingen af disse ventiler, ligesom for alle udligningsventiler, kr\u00e6ver en pr\u00e6cis indledende hydraulisk indstilling.<br \/>Som vi vil se senere, vil det, hvis afbalanceringen sker ved justering af gennemstr\u00f8mningsm\u00e6ngderne, v\u00e6re n\u00f8dvendigt at inddrage et ingeni\u00f8rfirma til at fastl\u00e6gge disse, da der ikke findes dokumentation for de eksisterende anl\u00e6g.<\/p>\n<p class=\"text-justify push-top\">\u00a0<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>INDUSTRIELLE AKT\u00d8RERS ANALYSE OG EKSPERTISE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\"><em>Der findes tre generationer af udligningsventiler side om side.<\/em><\/p>\n<p><strong>1<sup>\u00e6ra<\/sup> Generation: Statiske og ikke-volumetriske reguleringsventiler.<\/strong><br \/>Disse vandhaner g\u00f8r det ikke muligt at m\u00e5le gennemstr\u00f8mningshastighederne.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Ikke-volumetriske udligningsventiler\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec18.jpg\" alt=\"\" width=\"650\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\"><em>Figur 4: Ikke-volumetriske udligningsventiler<\/em><\/p>\n<p class=\"text-justify push-top\">Der findes to metoder til at indstille dem:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Hydraulisk simulering af fordelingerne<\/li>\n<li class=\"pad5\">Standardisering af returtemperaturerne for de antenner, der skal afbalanceres<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Den hydrauliske simulering af fordelingsnettene foruds\u00e6tter en detaljeret kortl\u00e6gning af fordelingsnettet (str\u00e6kningernes l\u00e6ngder, diametre osv.), en bestemmelse af de installerede ventileres hydrauliske adf\u00e6rd samt en beregning af de gennemstr\u00f8mningsm\u00e6ngder, der skal indstilles p\u00e5 hver forgreningsledning.<br \/>P\u00e5 eksisterende anl\u00e6g er det kompliceret at indsamle alle disse data, og de usikkerheder, der opst\u00e5r, begr\u00e6nser mulighederne for nemt at opn\u00e5 et godt resultat.<\/p>\n<p>N\u00e5r anl\u00e6ggene er udstyret med denne type ventiler, er den bedste l\u00f8sning at g\u00e5 frem p\u00e5 f\u00f8lgende m\u00e5de: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/methode-dequilibrage-equilog\/\" target=\"_blank\" rel=\"noopener noreferrer\">udj\u00e6vning af returtemperaturerne for de anl\u00e6g, der skal afbalanceres. <\/a><br \/>Denne nye metode vil blive pr\u00e6senteret senere.<\/p>\n<p><strong>2<sup>\u00e8me<\/sup> Generation: Statiske og volumetriske udligningsventiler.<\/strong><br \/>Disse ventiler g\u00f8r det muligt at m\u00e5le gennemstr\u00f8mningshastighederne.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Volumetriske udligningsventiler\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec5.jpg\" alt=\"\" width=\"451\" height=\"230\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 5: Volumetriske udligningsventiler <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> og <a class=\"bleu\" href=\"http:\/\/www.comap.fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">Comap<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Der findes tre metoder til at indstille dem:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Hydraulisk simulering af fordelingerne<\/li>\n<li class=\"pad5\">Indstilling og kontrol af gennemstr\u00f8mningshastigheder ved m\u00e5ling p\u00e5 stedet<\/li>\n<li class=\"pad5\">Ensretning af returtemperaturerne for de antenner, der skal afbalanceres<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Hvis man udelukker den f\u00f8rste l\u00f8sning p\u00e5 grund af de vanskeligheder, den medf\u00f8rer i forbindelse med eksisterende anl\u00e6g, skal det bem\u00e6rkes, at en justering af gennemstr\u00f8mningshastighederne ligeledes kr\u00e6ver inddragelse af et ingeni\u00f8rbureau til at fastl\u00e6gge den gennemstr\u00f8mningshastighed, der skal indstilles p\u00e5 hver enkelt antenne, der skal afbalanceres.<br \/>I eksisterende anl\u00e6g er den enkleste l\u00f8sning stadig at sikre ensartede returtemperaturer.<\/p>\n<p><strong>3<sup>\u00e8me<\/sup> Generation: Dynamiske udligningsventiler<\/strong><br \/>Denne nyeste generation af udligningsventiler er beregnet til montering p\u00e5 <strong>kredsl\u00f8b med variabel gennemstr\u00f8mning <\/strong>s\u00e5som dem, der er udstyret med termostatventiler.<\/p>\n<p>Man skal skelne mellem to typer vandhaner:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Udligningsventiler eller -haner \u00ab <em>differenstrykregulatorer <\/em>\u00bb<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Differenstrykreguleringsventiler\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec7.jpg\" alt=\"\" width=\"650\" height=\"207\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 6: Differenstrykreguleringsventiler <a class=\"bleu\" href=\"http:\/\/honeywell.com\/country\/fr\/Pages\/home.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">Honeywell<\/a> og <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">I et fordelingssystem udstyret med termostatventiler (Rth) stiger forsyningstrykforskellen (DP) i forgreningen, n\u00e5r disse \u00ablukkes\u00bb. Denne stigning i DP modvirker herefter lukningen af Rth og medf\u00f8rer en stigning i gennemstr\u00f8mningen i de radiatorer, hvis termostatventiler endnu ikke er lukket.<br \/>I denne situation registrerer differenstrykreguleringsventilen stigningen i differenstrykket og \u00ablukker\u00bb for at genoprette det.<\/p>\n<p>Visse modeller, s\u00e5som dem p\u00e5 billedet ovenfor, er ikke volumetriske og g\u00f8r det derfor ikke muligt at m\u00e5le de regulerede gennemstr\u00f8mninger. Indstillingen af disse modeller eller kontrollen af deres indstilling skal foretages ved m\u00e5ling af returtemperaturerne.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>\u00e8me<\/sup> Typer af dynamiske udligningsventiler: De automatiske udligningsventiler<\/strong> <em>(ogs\u00e5 kaldet selvbalancerende eller uafh\u00e6ngige af forsyningstrykket eller PIBCV eller gennemstr\u00f8mningsregulator)<\/em><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"S\u00e5kaldte \u00abautomatiske\u00bb udligningsventiler\u00bb\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec8.jpg\" alt=\"\" width=\"250\" height=\"253\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 7: S\u00e5kaldte \u00abautomatiske\u00bb udligningsventiler\u00bb <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Disse vandhaner er designet til at g\u00f8re det muligt at <strong>indstilling af en enkelt terminal<\/strong> f.eks. et varmeelement i et luftbehandlingsanl\u00e6g eller en ventilator-konvektor.<br \/>De kan v\u00e6re motoriserede og dermed g\u00f8re det muligt at regulere enheden, s\u00e5 den fungerer under de bedst mulige hydrauliske driftsbetingelser.<\/p>\n<p>De bruges undertiden til at udligne antenner, der best\u00e5r af <strong>flere udl\u00f8bere udstyret med 2-vejs reguleringsventiler<\/strong> s\u00e5som radiatorer udstyret med termostatventiler. De automatiske udligningsventiler erstatter i s\u00e5 fald de differenstrykreguleringsventiler, der normalt anvendes i denne situation.<\/p>\n<p>Denne situation var ikke forudset fra starten og er ikke n\u00e6vnt i producenternes tekniske specifikationer. Den automatiske udligningsventils funktion er nemlig ikke helt optimal i dette tilf\u00e6lde og ligner i denne situation funktionen af en statisk udligningsventil.<\/p>\n<p>Man kan l\u00e6se mere om, hvordan det fungerer, i artiklen: <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u00abAutomatisk afbalancering \u2013 betingelserne for succes\u00bb<\/a><\/p>\n<p>I kommentarerne i slutningen af denne artikel kan man l\u00e6se to store producenters synspunkter.<br \/>IMI \u2013 Hydronic pr\u00e6ciserer s\u00e5ledes:<br \/><em>\u00abHvad ang\u00e5r installation af automatiske ventiler (PIBCV, i dette tilf\u00e6lde en gennemstr\u00f8mningsregulator) i systemer med variabel gennemstr\u00f8mning (f.eks. boliger udstyret med termostatventiler) forpligter vores rolle som eksperter og specialister inden for hydraulik os til at fremf\u00f8re et teknisk ufejlbarligt synspunkt. Selvom det m\u00e5 konstateres, at installationen af PIBCV ved indgangen til boliger er i stigning, kan vi af etiske grunde ikke tilskynde til denne praksis.\u00bb<\/em><\/p>\n<p>Oventrop udtaler sig mere pragmatisk om det samme emne og siger <em>at selv om der er tale om et teknisk kompromis med hensyn til hydraulikken, er den generelle regulering, der opn\u00e5s med automatiske ventiler, alligevel langt bedre end den, der opn\u00e5s med statiske ventiler og trykreguleringsventiler, da disse oftest kun er indstillet i ringe grad eller slet ikke.<\/em><\/p>\n<p>Det er rigtigt, at indstillingen af ventilerne til regulering af differenstrykket ofte lader meget tilbage at \u00f8nske, is\u00e6r p\u00e5 modeller, der ikke er volumetriske. Hvis man ikke arbejder ud fra m\u00e5linger af returtemperatur, kan indstillingen kun foretages p\u00e5 baggrund af en hypotetisk beregning af tryktab. Hvis man \u00f8nsker at udf\u00f8re balanceringen ved hj\u00e6lp af gennemstr\u00f8mningsm\u00e5linger, er det absolut n\u00f8dvendigt at v\u00e6lge volumetriske modeller, og flere m\u00e6rker tilbyder volumetriske ventiler, der kan tilpasses.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Volumetrisk ventil udstyret med en Oventrop-differenstrykreguleringsventil\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec17.jpg\" alt=\"\" width=\"513\" height=\"150\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 6a: Volumetrisk ventil udstyret med en differenstrykreguleringsventil <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Afslutningsvis skal det derfor is\u00e6r bem\u00e6rkes, at man ikke m\u00e5 forveksle \u00abmontering af vandhaner\u00bb med \u00abjustering af vandhaner\u00bb, uanset hvilken generation af modeller der er tale om.<\/p>\n<p>Ligesom for de tidligere generationer skal de dynamiske balanceringsventiler gennemg\u00e5 en omhyggelig indledende indstilling. Denne indstilling kan foretages ved hj\u00e6lp af simulering og\/eller gennemstr\u00f8mningsm\u00e5linger og\/eller m\u00e5ling af returtemperaturerne. Emnet vil blive uddybet i det f\u00f8lgende afsnit.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>METODER TIL UDLIGNING<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">I eksisterende f\u00e6llesvarmeanl\u00e6g, <strong>tre metoder <\/strong>til den indledende indstilling af udligningsventilerne anvendes i dag.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>1<sup>\u00e6ra<\/sup> metode: Simulering af netv\u00e6rkenes hydrauliske adf\u00e6rd<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Simulering af netv\u00e6rkenes hydrauliske adf\u00e6rd\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec9.jpg\" alt=\"\" width=\"492\" height=\"446\" \/><\/p>\n<p class=\"text-justify push-top\">P\u00e5 eksisterende anl\u00e6g er det teoretisk muligt at foretage de n\u00f8dvendige m\u00e5linger til at estimere gennemstr\u00f8mningshastigheder og tryktab i kredsl\u00f8bene for derved beregne den rette forindstilling af udligningsventilerne. Det er dog en vanskelig \u00abskattejagt\u00bb, medmindre man kan benytte sig af fordelingsplaner, som sj\u00e6ldent er tilg\u00e6ngelige.<\/p>\n<p>Denne mulighed, som is\u00e6r er udviklet af <a class=\"bleu\" href=\"http:\/\/edipa.fr\/LibrairieTechnique\/Auteur?auteur=FRIDMANN%20Pierre&amp;page=1\" target=\"_blank\" rel=\"noopener noreferrer\">Hr. Pierre Fridmann<\/a> kr\u00e6ver, at man efterf\u00f8lgende kan kontrollere resultatet af alle de foretagne forindstillinger, enten ved at m\u00e5le gennemstr\u00f8mningshastighederne eller ved at m\u00e5le returvandstemperaturerne.<\/p>\n<p>Denne metode er is\u00e6r beregnet til nye eller nyere anl\u00e6g, hvor der endnu ikke er opst\u00e5et uforudsete tilstopninger, og hvor alle de n\u00f8dvendige beregningsdata foreligger.<br \/>Den kan blandt andet bruges til at bestemme de trykforskelle, der skal indstilles p\u00e5 \u00abdifferenstrykregulatorer\u00bb, som har indstillingsskalaer i trykenheder.<br \/>Simuleringsresultatet g\u00f8r det muligt at foretage en forindstilling af armaturerne, inden de faktisk opn\u00e5ede vandgennemstr\u00f8mninger eller returvandstemperaturer derefter kontrolleres og justeres p\u00e5 stedet.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>\u00e8me<\/sup> metode: Beregning, indstilling og kontrol af de gennemstr\u00f8mningsm\u00e6ngder, der skal transporteres<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Metoden g\u00e5r ud p\u00e5 at beregne og regulere de gennemstr\u00f8mningsm\u00e6ngder, der skal transporteres. Den kr\u00e6ver naturligvis anvendelse af s\u00e5kaldte \u00abvolumetriske\u00bb ventiler \u2013 enten statiske eller dynamiske \u2013 som g\u00f8r det muligt at m\u00e5le gennemstr\u00f8mningsm\u00e6ngderne.<br \/>Den finder derfor ikke anvendelse p\u00e5 <strong>ikke-volumetriske ventiler<\/strong> s\u00e5som de enkle reguleringsventiler, der er monteret ved radiatorernes udl\u00f8b, men ogs\u00e5 ved s\u00f8jlefoden og is\u00e6r i returledningen fra gulvvarme-kredsl\u00f8bene.<\/p>\n<p>Det skal ogs\u00e5 bem\u00e6rkes, at visse differenstrykreguleringsventiler ikke er volumetriske. Indstillingen af disse eller kontrollen af deres indstilling skal udelukkende foretages ved m\u00e5ling af returtemperaturerne.<\/p>\n<p>I eksisterende anl\u00e6g skal et ingeni\u00f8rfirma, med henblik p\u00e5 fastl\u00e6ggelse af de gennemstr\u00f8mningsm\u00e6ngder, der skal reguleres, foretage de n\u00f8dvendige m\u00e5linger til at estimere varmetabene for hver af de varmeantenner, der skal behandles.<br \/>Til det form\u00e5l skal han beregne varmetabene fra standardlokaler og s\u00e6rlige lokaler (under terrassen, op ad gavlen osv.). Derefter skal han \u2013 hvilket ofte er meget vanskeligt \u2013 korrekt fordele disse tab p\u00e5 hver af de antenner, der skal indstilles.<\/p>\n<p>Indstilling af gennemstr\u00f8mningshastigheder kr\u00e6ver brug af et m\u00e5les\u00e6t, og hvis ventilerne ikke er dynamiske, kr\u00e6ver det anvendelse af en s\u00e6rlig metode.<br \/>Man kan k\u00f8be en af disse metoder p\u00e5 <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-debit.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Eformation Xpair<\/a> eller p\u00e5 <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulator.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Gennemstr\u00f8mningskontrol\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec10.jpg\" alt=\"\" width=\"551\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 9: Gennemstr\u00f8mningskontrol \u2013 Kilde <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> og m\u00e5lekasse <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Hvis de vandhaner, der skal justeres, er<strong> af dynamisk type <\/strong>Indstillingen af gennemstr\u00f8mningshastighederne kan foretages lettere uden brug af en s\u00e6rlig metode, bortset fra at man skal kontrollere, at den vandhane, der er d\u00e5rligst forsynet, har et tilstr\u00e6kkeligt trykforskel i forsyningen.<\/p>\n<p>P\u00e5 visse dynamiske ventiler med gennemstr\u00f8mningsindstilling kan forindstillingen foretages uden m\u00e5ling, men dette fritager ikke for den afsluttende m\u00e5ling af de opn\u00e5ede gennemstr\u00f8mninger, n\u00e5r alle ventiler er blevet forindstillet.<br \/>P\u00e5 modeller uden gennemstr\u00f8mningsskala, is\u00e6r ventiler til regulering af differenstryk, kan gennemstr\u00f8mningen kun indstilles ved faktisk m\u00e5ling (hvis de i \u00f8vrigt er af den volumetriske type).<\/p>\n<p>N\u00e5r alle dynamiske ventiler er blevet indstillet eller forindstillet \u2013 hvis der er tale om volumetriske ventiler \u2013 afsluttes en grundig afbalancering med en m\u00e5ling af alle gennemstr\u00f8mningshastigheder for at sikre, at de hydrauliske interaktioner mellem forgreningerne er blevet h\u00e5ndteret korrekt.<br \/>Man skal jo huske p\u00e5, at det kun kr\u00e6ver nogle f\u00e5 d\u00e5rligt placerede antenner, f\u00f8r man er n\u00f8dt til at overbelaste resten af distributionsnettet, og kredsl\u00f8benes hydrauliske adf\u00e6rd \u2013 is\u00e6r i eksisterende anl\u00e6g \u2013 byder ofte p\u00e5 mange overraskelser.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>3<sup>\u00e8me<\/sup> metode: M\u00e5ling og standardisering af returvandtemperaturerne i fyringss\u00e6sonen<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Denne nyere l\u00f8sning, der kaldes \u00abEQUILOG-metoden\u00bb, g\u00e5r ud p\u00e5, at n\u00e5r varmeanl\u00e6gget er i drift og udgangstemperaturen er stabiliseret, skal man <strong>m\u00e5le returvandstemperaturerne <\/strong>at afbalancere og udj\u00e6vne antennerne, s\u00e5ledes at alle de antenner, der skal justeres, er \u00ablige varme\u00bb i forhold til hinanden.<\/p>\n<p>Selvom fremgangsm\u00e5den forekommer \u00abforenklet\u00bb, har den v\u00e6ret \u2013 og er stadig \u2013 genstand for helt naturlig kritik fra konkurrenterne. Man kan l\u00e6se mere om dette emne <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-hydraulique-methode-simple.htm\" target=\"_blank\" rel=\"noopener\">\u00abHydraulisk afbalancering: nyt om en enkel metode\u00bb. <\/a>Men det kan konstateres, at der p\u00e5 flere hundrede lokaliteter til dato er blevet behandlet over 80.000 bolig\u00e6kvivalenter p\u00e5 en rentabel m\u00e5de.<\/p>\n<p>Efter afbalanceringen vil antennerne udvise sammenlignelige returtemperaturer og temperaturforskelle mellem frem- og returled <em>(*)<\/em>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Udj\u00e6vning af vandtemperaturerne i et varmesystem\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec12.gif\" alt=\"\" width=\"573\" height=\"229\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur 11: Udj\u00e6vning(*) af vandtemperaturerne i et varmesystem<\/em><\/p>\n<p class=\"text-justify push-top\"><em>(*) N\u00e5r det vandforsyningssystem tillader det, er det naturligvis muligt at indstille forskellige vandtemperaturer p\u00e5 hver grenledning for at tage h\u00f8jde for lokale isoleringsforanstaltninger. <\/em><br \/><em>Det kan dog konstateres, at i bygninger, der har gennemg\u00e5et en ensartet termisk renovering (udskiftning af alle vinduer og d\u00f8re, isolering af alle udvendige lodrette v\u00e6gge), er balancen <u>f\u00f8r eller efter<\/u> Det er tilstr\u00e6kkeligt at opn\u00e5 et godt resultat ved at sikre ensartede vandtemperaturer. <\/em><br \/><em>Varmeeffekten kan derefter justeres ved blot at indstille vandtemperaturen ved udgangen fra fyrrummet (indstilling af opvarmningskurven).<\/em><\/p>\n<p>Fremgangsm\u00e5den, der kan anvendes p\u00e5 alle typer vandhaner, er blevet optimeret takket v\u00e6re fremskridt inden for infrar\u00f8d termometri og den forskning, der er udf\u00f8rt af GMTI94 \u2013 GEFEn.<br \/>Man kan unders\u00f8ge princippet bag det p\u00e5 <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-temp.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Eformation Xpair<\/a> eller p\u00e5 <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulator<\/a>.<\/p>\n<p>Den st\u00f8rste fordel ved denne metode er, at man kan undg\u00e5 alle beregninger af tab og opm\u00e5linger af anl\u00e6g i netv\u00e6rk, der er dimensioneret efter standard. Den er derfor s\u00e6rligt velegnet til eksisterende kredsl\u00f8b, hvor der sj\u00e6ldent findes arkivoplysninger.<\/p>\n<p>Denne fremgangsm\u00e5de, der blev afpr\u00f8vet i praksis i 2000&#x27;erne, er blevet patenteret i Frankrig og for nylig i 15 europ\u00e6iske lande.<br \/>\u00abEQUILOG\u00bb-metoden anvendes blandt andet af <em>\u00ab <\/em><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><em>virksomheden MAPSEC <\/em><\/strong><\/a><em>\u00bb(*) <\/em>p\u00e5 vegne af forskellige drifts- og installationsvirksomheder (Dalkia, Cofely-Soccram, Idex osv.).<br \/><em>(*) MAPSEC, 80 rue de Paris, 93100 Montreuil, Tlf.: 01 48 59 06 05 \u2013 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr<\/a><\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Cirkulationspumpe\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec11.jpg\" alt=\"\" width=\"250\" height=\"187\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figur nr. 10: Kontrol af vandtemperaturen Kilde <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/\" target=\"_blank\" rel=\"noopener noreferrer\">Mapsec<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Endelig skal det bem\u00e6rkes, at i <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">artiklen om dynamiske udligningsventiler<\/a> Som n\u00e6vnt i det foreg\u00e5ende afsnit angiver ingeni\u00f8ren, der repr\u00e6senterer Oventrop, dette i kommentarerne i slutningen af dokumentet.<br \/><em>\u00abHvad ang\u00e5r det eksisterende anl\u00e6g, er udligning ved at ensrette returtemperaturerne efter min mening ogs\u00e5 den bedste metode, forudsat at det valgte temperaturfald er korrekt.\u00ab.<br \/>Alligevel er denne metode tidskr\u00e6vende og bliver ikke let accepteret af installat\u00f8rer, der er specialiserede i boliger, n\u00e5r den skal udf\u00f8res manuelt.<br \/>\u00bbDer findes vandhaner, der g\u00f8r det automatisk, men prisen er en anden\u00ab<\/em><\/p>\n<p>Det er rigtigt, at udligning ved at ensrette returtemperaturerne tidligere kr\u00e6vede lange ventetider, indtil temperaturen havde stabiliseret sig, men de seneste fremskridt g\u00f8r det i dag muligt at undg\u00e5 dette, og varigheden af operationerne er nu blevet meget konkurrencedygtig.<\/p>\n<p>Man kunne i \u00f8vrigt faktisk overveje automatisk at opn\u00e5 og opretholde balancen ved at udj\u00e6vne returtemperaturerne. Men med den nuv\u00e6rende teknologi ville dette kr\u00e6ve installation og str\u00f8mforsyning af automatiske, motoriserede udligningsventiler, der er tilsluttet en styreenhed eller et bygningsstyringssystem.<br \/>Set ud fra et \u00f8konomisk synspunkt er det forel\u00f8big sv\u00e6rt at forestille sig, i hvert fald n\u00e5r det g\u00e6lder de eksisterende anl\u00e6g.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>INSTALLAT\u00d8RERNES ANALYSE OG FAGLIGE KOMPETENCE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Man skal is\u00e6r skelne klart mellem afbl\u00e6sning (n\u00e5r det er n\u00f8dvendigt) og montering af udligningsventiler p\u00e5 den ene side og selve den indledende indstilling af disse p\u00e5 den anden side.<\/p>\n<p>Uanset hvilken type vandhane der er tale om, er det nemlig fristende for et installations- eller rensningsfirma at medtage idrifts\u00e6ttelsen i sit tilbud, uden altid at v\u00e6re i stand til at fastl\u00e6gge alle parametrene.<\/p>\n<p>Man kan selvf\u00f8lgelig forestille sig, at \u00e9t og samme firma kan varetage hele en oml\u00e6gning, men det foruds\u00e6tter, at det r\u00e5der over teams med meget forskelligartet praktisk og teoretisk ekspertise.<\/p>\n<p>Generelt skal man derfor v\u00e6re yderst forsigtig, n\u00e5r man v\u00e6lger en virksomhed, der skal udf\u00f8re en afbalancering. Det er et vanskeligt teknisk speciale, og der er mange tilf\u00e6lde af utilfredsstillende resultater, da det er sv\u00e6rt at kontrollere kvaliteten af det udf\u00f8rte arbejde.<\/p>\n<p>Selv om det skulle medf\u00f8re ekstraomkostninger, vil vi derfor ikke t\u00f8ve med at opdele opgaverne, s\u00e5ledes at unders\u00f8gelses- og\/eller udviklingsfaserne varetages af specialister p\u00e5 omr\u00e5det.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radiator\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec13.jpg\" alt=\"\" width=\"450\" height=\"173\" \/><\/p>\n<p class=\"text-justify push-top\">En god m\u00e5de at v\u00e6lge p\u00e5 er at sp\u00f8rge under konsultationen, hvilken metode der vil blive anvendt, og at f\u00e5 pr\u00e6ciseret, hvilke data der vil blive leveret efter operationen.<br \/>Enhver uklarhed eller t\u00f8ven i svarene p\u00e5 et af disse to punkter vil uden tvivl v\u00e6re et tegn p\u00e5 en pr\u00e6station, der ikke er helt p\u00e5 plads.<\/p>\n<p>Hvis virksomheden arbejder ud fra gennemstr\u00f8mningsm\u00e5linger eller hydrauliske simuleringer, kan man s\u00e5ledes anmode om, at tilbuddet indeholder den endelige rabat:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Detaljeret beregning af tab <strong>i forbindelse med hver enkelt vandhane, der skal behandles<\/strong> og som har f\u00f8rt til fasts\u00e6ttelsen af de bel\u00f8b, der skal betales. Man kan s\u00e5ledes sikre sig, at de p\u00e5g\u00e6ldende bel\u00f8b ikke er resultatet af grove sk\u00f8n.<\/li>\n<li class=\"pad5\">Fra et gitter <strong>certificeret<\/strong> de m\u00e5lte gennemstr\u00f8mninger <u>n\u00e5r alle vandhaner er blevet justeret<\/u> (og ikke n\u00f8jes med tabellen over de teoretisk forventede gennemstr\u00f8mningshastigheder). P\u00e5 den m\u00e5de kan man sikre sig, at de hydrauliske interaktioner mellem de antenner, der skal justeres, rent faktisk er taget i betragtning, og om n\u00f8dvendigt kontrollere dette.<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Hvis virksomheden arbejder ud fra m\u00e5linger af returtemperaturer, kan man anmode om, at tilbuddet indeholder:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Nogle relevante referencer eller, endnu bedre, freml\u00e6ggelse af mindst \u00e9n detaljeret rapport fra en tidligere gennemf\u00f8rt opgave. P\u00e5 den m\u00e5de kan man sikre sig, at ans\u00f8geren har den n\u00f8dvendige erfaring, for selvom princippet bag metoden er gammelt, er det f\u00f8rst for nylig, at man virkelig har f\u00e5et styr p\u00e5 den.<\/li>\n<li class=\"pad5\">Gengivelse af et diagram <strong>certificeret, fuldst\u00e6ndig og detaljeret<\/strong> de m\u00e5lte returtemperaturer,<strong> f\u00f8r og efter afbalancering<\/strong>, med angivelse af de stabiliserede udgangstemperaturer, ved hvilke disse m\u00e5linger er foretaget. P\u00e5 den m\u00e5de kan man sikre sig, at arbejdet er udf\u00f8rt korrekt.<\/li>\n<\/ul>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>RENTABILITET OG ENERGIBESPARELSER<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Det er ikke let at forudsige, hvor stor en energibesparelse man kan forvente af en afbalancering.<br \/>Selv om man i tilf\u00e6lde af en perfekt udf\u00f8rt udligning kan estimere den ud fra et kort over de indledende omgivelsestemperaturer, er dette kort i virkeligheden meget vanskeligt at fortolke.<br \/>Under alle omst\u00e6ndigheder skal man, hvis man v\u00e6lger denne beregningsmetode, basere sig p\u00e5 registreringer foretaget i meget kolde perioder og uden nogen form for gratis tilf\u00f8rsel (solindstr\u00e5ling, elektrisk udstyr osv.) og ikke p\u00e5 \u00f8jeblikkelige m\u00e5linger.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Eksempel p\u00e5 registrering af rumtemperaturer, der er p\u00e5virket af gratis tilf\u00f8rsler\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec15.jpg\" alt=\"\" width=\"400\" height=\"235\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Fig. 15: Eksempel p\u00e5 registrering af rumtemperaturer, der er p\u00e5virket af gratis tilf\u00f8rsler<\/em><\/p>\n<p class=\"text-justify push-top\">Men endnu mere kompliceret er det at tage h\u00f8jde for placeringen af de balanceringsventiler, der rent faktisk kan justeres. I eksisterende varmeanl\u00e6g foretages balanceringen nemlig som regel kun p\u00e5 de ventiler, der er tilg\u00e6ngelige fra 2<sup>\u00e8me<\/sup> niveau (se 2<sup>\u00e8me<\/sup> \u00a7). Derfor er den mere eller mindre vellykkede implementering af dette 2<sup>\u00e8me<\/sup> Niveauet er en afg\u00f8rende faktor for vurderingen af den forventede energibesparelse.<\/p>\n<p>I denne henseende anvender virksomheden MAPSEC en s\u00e5kaldt metode <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/ecomapsec\/\" target=\"_blank\" rel=\"noopener noreferrer\">REQUILOG<\/a> som g\u00f8r det muligt for ham, ud fra et kort over de m\u00e5lte returvandstemperaturer ved de vandhaner, der skal justeres, at vurdere omfanget af den ubalance, der rent faktisk kan afhj\u00e6lpes.<br \/>N\u00e5r det er muligt, indledes de udligningsforanstaltninger, som den har til opgave at gennemf\u00f8re, derfor med en diagnostisk unders\u00f8gelse, der omfatter denne vurdering, hvilket giver beslutningstageren mulighed for bedre at vurdere, om det er hensigtsm\u00e6ssigt at gennemf\u00f8re foranstaltningen eller ej.<\/p>\n<p>Endelig skal det bem\u00e6rkes, at den energibesparelse, der f\u00f8lger af en afbalancering, vil kr\u00e6ve, at den tekniker, der har ansvaret for indstillingen af reguleringssystemet, senere bliver inddraget.<br \/>For hvis udligningen i sidste ende skulle best\u00e5 i at bringe de lokaler, der oprindeligt var d\u00e5rligst opvarmede, op p\u00e5 samme niveau som de bedst opvarmede, ville det jo ikke v\u00e6re en energibesparelse, man opn\u00e5ede\u2026<\/p>\n<p>Samlet set ser det ud til, at den gennemsnitlige energibesparelse (%) efter justering af varmefordelingen ligger p\u00e5 omkring 7%, med en tilbagebetalingstid p\u00e5 omkring 2 til 3 \u00e5r, hvis systemet ikke kr\u00e6ver udskiftning af ventiler eller kun i begr\u00e6nset omfang.<\/p>\n<p>Indtil december 2014 kunne disse tiltag indg\u00e5 i ordningen med energibesparelsescertifikater med en fastsat energibesparelsesprocent p\u00e5 10%.<br \/>De tilh\u00f8rende BAR- og BAT SE 04-datablade er i \u00f8jeblikket ved at blive \u00e6ndret. De forventes at blive genudgivet under andre betegnelser i den kommende ministerielle bekendtg\u00f8relse om CEE.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"ECO-knap\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec14.jpg\" alt=\"\" width=\"250\" height=\"180\" \/><\/p>\n<p class=\"text-justify push-top\">Afslutningsvis kan man med sikkerhed sige, at udligningsforanstaltningerne generelt er yderst rentable, hvis de gennemf\u00f8res med omhu.<\/p>\n<p>Det bedste bevis herp\u00e5 er det arbejde, der er udf\u00f8rt af Dalkias udligningsafdeling i IdF(*), som blev oprettet for omkring ti \u00e5r siden med henblik p\u00e5 at anvende EQUILOG-metoden og som i dag ledes af Christophe Tillay.<br \/>P\u00e5 Xpair kan man l\u00e6se en beretning om et af hans projekter i artiklen <a class=\"bleu\" href=\"http:\/\/conseils.xpair.com\/actualite_experts\/exemple-operation-equilibrage-egalisation-temperatures-retour.htm\" target=\"_blank\" rel=\"noopener noreferrer\">\u00abUdligningsproces ved hj\u00e6lp af ensartetg\u00f8relse af returtemperaturerne\u00bb.<\/a><\/p>\n<p><em>(*) Dalkia Ile-de-France, Afbalanceringsafdelingen, 28 Boulevard de Pesaro, 92 751 NANTERRE CEDEX Tlf.: 01 55 67 68 97 <\/em><\/p>\n<p>De hundredvis af udligningsforanstaltninger, som denne afdeling har gennemf\u00f8rt, er udelukkende blevet udf\u00f8rt p\u00e5 boligkomplekser, der forvaltes af selskabet inden for rammerne af MF-kontrakter (fastpris-kontrakter) eller MT-kontrakter (temperaturkontrakter). I forbindelse med denne type kontrakter, som ikke er s\u00e6rlig udbredt, betaler kunden \u00e5rligt et fast bel\u00f8b (eller et bel\u00f8b justeret i henhold til DJU) til driftsselskabet som garanti for optimal opvarmning.<\/p>\n<p>Forsyningen af br\u00e6ndsel er s\u00e5ledes udelukkende driftsselskabets ansvar. Det ligger derfor i selskabets interesse at reducere forbruget, s\u00e5 l\u00e6nge kunden stadig f\u00e5r en tilfredsstillende opvarmning, da alle de opn\u00e5ede energibesparelser tilfalder selskabet.<\/p>\n<p>Denne type aftale tilskynder naturligvis tjenesteudbyderen til at forvalte anl\u00e6gget bedst muligt og s\u00e6tte sine bedste teams p\u00e5 opgaven. Set ud fra et milj\u00f8m\u00e6ssigt synspunkt er situationen s\u00e5ledes optimal.<br \/>Kunden f\u00e5r derimod \u2013 uden s\u00e6rlige ekstraomkostninger \u2013 garanti for et holdbart og korrekt indstillet varmesystem samt garanti for, at anl\u00e6gget ved udl\u00f8bet af kontrakterne, der typisk l\u00f8ber over 8 \u00e5r, vil v\u00e6re s\u00e5 velvedligeholdt som muligt.<\/p>\n<p>De afbalanceringer, der blev udf\u00f8rt af Dalkia IdFs afbalanceringsafdeling, blev derfor finansieret med egne midler og afskrevet i l\u00f8bet af f\u00e5 \u00e5r takket v\u00e6re de deraf f\u00f8lgende energibesparelser.<br \/>At denne tjeneste har kunnet opretholdes og udbygges i l\u00f8bet af de sidste 10 \u00e5r, er et ubestrideligt bevis p\u00e5, at denne type aktiviteter er rentable.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Balancekurve\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec16.jpg\" alt=\"\" width=\"400\" height=\"250\" \/><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\" style=\"text-align: left;\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>KONKLUSION<\/h2>\n<\/div>\n<p class=\"text-justify push-top\" style=\"text-align: left;\">Neds\u00e6ttelsen af energiforbruget i vores eksisterende f\u00e6llesvarmesystemer bygger p\u00e5 isolering, korrekt indstilling af forbr\u00e6ndingen, regulering og afbalancering.<\/p>\n<p style=\"text-align: left;\">P\u00e5 trods af sin store indflydelse p\u00e5 reguleringen og udbyttet af kondensationskedler (og kraftvarmeanl\u00e6g) har det sidste led hidtil v\u00e6ret det svage led.<\/p>\n<p style=\"text-align: left;\">Efter en meget lang pause har problemet aldrig v\u00e6ret mere aktuelt.<\/p>\n<p style=\"text-align: left;\">De seneste fremskridt inden for ventiler og udvikling b\u00f8r g\u00f8re det muligt at udnytte et af de vigtigste tilbagev\u00e6rende potentialer for energibesparelser bedre.<\/p>\n<\/div>\n<h4 class=\"text-primary push-top\" style=\"text-align: left;\"><strong>KILDER OG LINKS<\/strong><\/h4>\n<ul class=\"push-top\">\n<li class=\"pad10\" style=\"text-align: left;\">OPLYSNINGER: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/justering\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mise-au-point<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">IDRIFTS\u00c6TTELSE AF VVS-ANL\u00c6G: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/idriftsaettelse\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/commissioning<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">FELTINSPEKTION: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/revision\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/audit<\/a><\/li>\n<li style=\"text-align: left;\">T\u00c6THEDSTEST Luftkanalsystemer:\u00a0<a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mesure-de-letancheite-a-lair-des-reseaux-aeraulique<\/a><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/da\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">s<\/a><\/li>\n<li style=\"text-align: left;\">SIMULATOR L\u00e6r at afbalancere: <a href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564\" target=\"_blank\" rel=\"noopener\">www.edipa.fr\/LibrairieTechnique\/Details\/564<\/a><\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Par Patrick DELPECH &#8211; pour la soci\u00e9t\u00e9 MAPSEC &#8211; Mars 2020 Pour les responsables techniques et d\u00e9cideurs (maitres d\u2019ouvrage, syndic, etc.), les nouveaut\u00e9s du secteur, les<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16263","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/posts\/16263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/comments?post=16263"}],"version-history":[{"count":4,"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/posts\/16263\/revisions"}],"predecessor-version":[{"id":17284,"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/posts\/16263\/revisions\/17284"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/media?parent=16263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/categories?post=16263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/da\/wp-json\/wp\/v2\/tags?post=16263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}