<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>INFO – MAPSEC</title>
	<atom:link href="https://mapsec.fr/en/category/info/feed/" rel="self" type="application/rss+xml" />
	<link>https://mapsec.fr/en</link>
	<description>Our drive for performance</description>
	<lastBuildDate>Sun, 29 Mar 2020 14:26:31 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updateperiod>
	once an hour	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=7.0.3</generator>

<image>
	<url>https://mapsec.fr/wp-content/uploads/2026/04/cropped-logo-e1782722498506-32x32.png</url>
	<title>INFO – MAPSEC</title>
	<link>https://mapsec.fr/en</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Press:</title>
		<link>https://mapsec.fr/en/2020/03/29/https-advice-xpair-com-consult_expert_word-hydraulic_balancing-primary_network-cea_saclay-htm/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 29 Mar 2020 14:26:31 +0000</pubDate>
				<category><![CDATA[INFO]]></category>
		<category><![CDATA[Equilibrage hydraulique CEA Sacaly]]></category>
		<category><![CDATA[Equilog]]></category>
		<guid ispermalink="false">http://mapsec.fr/?p=17042</guid>

					<description><![CDATA[Presentation of the network and balancing operation The CEA Saclay primary network was balanced using the EQUILOG(*) method during the heating season<span class="excerpt-hellip"> […]</span>]]></description>
										<content:encoded><![CDATA[<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:100%">
<div class="wp-block-image"><figure class="aligncenter size-full is-resized"><a href="https://conseils.xpair.com/consulter_parole_expert/equilibrage-hydraulique-reseau-primaire-cea-saclay.htm" target="_blank" rel="noopener"><img decoding="async" src="https://mapsec.fr/wp-content/uploads/2025/06/logo-xpair.png" alt="Link" class="wp-image-16004" width="360" height="94"/></a></figure></div>



<h3 id="block-d5f389c7-9bf8-47f2-a197-2f563c18598b" class="block-editor-rich-text__editable block-editor-rich-text__editable block-editor-block-list__block wp-block is-selected has-text-align-left has-luminous-vivid-orange-color has-text-color rich-text block-editor-block-list__block wp-block is-selected rich-text" tabindex="0" role="group" contenteditable="true" aria-multiline="true" aria-label="Block: Title" data-block="d5f389c7-9bf8-47f2-a197-2f563c18598b" data-type="core/heading" data-title="Titre">Presentation of the network and the balancing operation.</h3>



<hr class="wp-block-separator has-text-color has-background has-luminous-vivid-orange-background-color has-luminous-vivid-orange-color is-style-wide"/>
</div>
</div>



<p class="has-text-align-left wp-block-paragraph">The primary network of the CEA in Saclay was balanced using the EQUILOG(*) method during the 2018/2019 heating season.<br><em>(*) Method of balancing by homogenisation of return temperatures, patents for condominiums belonging to the company Mapsec&nbsp;<a rel="noreferrer noopener" href="http://mapsec.fr/en/" target="_blank" data-type="URL" data-id="http://mapsec.fr">h</a><a href="http://mapsec.fr/en/" data-type="URL" data-id="http://mapsec.fr" target="_blank" rel="noreferrer noopener">ttp://mapsec.fr</a>&nbsp;and the Ministry of National Education.</em><br><br>The need for the primary network balancing operation at CEA Saclay arose from the connection of a new 2.2 MW substation.<br><br>The network supplies 89 exchangers distributed across 81 substations, for a total installed capacity of 88 MW. It is supplied from a combined heat and power plant.<br>69 heat exchangers exclusively supply radiator circuits and air handling units at a nominal temperature of 80/60 °C.<br>→ 25 heat exchangers partly supply floor panels at a nominal temperature of 50/40 °C.</p>



<p class="has-text-align-left wp-block-paragraph">The substations are equipped with plate heat exchangers. The temperature control at the secondary outlet of the exchangers is carried out by two-way control valves installed on the primary side of the exchangers.</p>



<div style="height:34px" aria-hidden="true" class="wp-block-spacer"></div>



<div class="wp-block-image"><figure class="aligncenter is-resized"><img fetchpriority="high" decoding="async" src="https://media.xpair.com/redac/regulation/cea.JPG" alt="CEA" width="591" height="352"/><figcaption><em><strong>Source and link to follow:</strong> <a rel="noreferrer noopener" href="https://conseils.xpair.com/consulter_parole_expert/equilibrage-hydraulique-reseau-primaire-cea-saclay.htm" target="_blank"> Pair of Xs </a></em></figcaption></figure></div>



<div class="wp-block-buttons aligncenter is-layout-flex wp-block-buttons-is-layout-flex"></div>



<div class="wp-block-buttons aligncenter is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background" href="https://mapsec.fr/en/contact/" style="border-radius:2px" target="_blank" rel="noreferrer noopener">Request a quote</a></div>



<div class="wp-block-button is-style-outline is-style-outline--1"><a class="wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background" href="https://mapsec.fr/en/methode-dequilibrage-equilog/" style="border-radius:2px">EQUILOG Method</a></div>



<div class="wp-block-button is-style-outline is-style-outline--2"><a class="wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background" href="https://conseils.xpair.com/consulter_parole_expert/equilibrage-hydraulique-reseau-primaire-cea-saclay.htm" style="border-radius:2px" target="_blank" rel="noopener">Site Xpair</a></div>
</div>



<hr class="wp-block-separator"/>



<h4 class="has-text-align-left wp-block-heading"><strong><span class="has-inline-color has-luminous-vivid-orange-color">MAPSEC in the press:</span></strong></h4>



<h5 class="has-text-align-left wp-block-heading"><strong>Sources and Links</strong></h5>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:100%">
<p class="has-text-align-left wp-block-paragraph"><strong>XPair.com</strong>  <em>Heating, air conditioning and ventilation solutions for buildings, complying with thermal and environmental building regulations. Advice on...</em></p>



<div class="wp-block-group"><div class="wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow">
<p class="has-text-align-left wp-block-paragraph">.    <a rel="noreferrer noopener" href="https://conseils.xpair.com/consulter_parole_expert/tout-equilibrage-hydraulique.htm" target="_blank">All about static and automatic hydraulic balancing</a></p>



<p class="has-text-align-left wp-block-paragraph">.    <a rel="noreferrer noopener" href="https://conseils.xpair.com/actualite_experts/equilibrage-dynamique-chauffage.htm" target="_blank">Automatic heating balancing, conditions for success</a></p>



<p class="has-text-align-left wp-block-paragraph">.     <a rel="noreferrer noopener" href="https://conseils.xpair.com/actualite_experts/exemple-operation-equilibrage-egalisation-temperatures-retour.htm" target="_blank">Balancing operation by measuring return temperatures</a></p>



<p class="has-text-align-left wp-block-paragraph"><strong>.  </strong>   <a rel="noreferrer noopener" href="https://conseils.xpair.com/actualite_experts/equilibrage-temperatures-retour-reseaux-primaires.htm" target="_blank">Balancing and return temperatures of primary networks</a></p>



<p class="has-text-align-left wp-block-paragraph"><strong>.   </strong>  <a rel="noreferrer noopener" href="https://conseils.xpair.com/actualite_experts/equilibrage-par-uniformisation-temperatures-retour.htm" target="_blank">Balancing by uniformisation of return temperatures: achievements</a></p>
</div></div>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:100%">
<div class="wp-block-group"><div class="wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow">
<p class="has-text-align-left wp-block-paragraph"><strong>Hot Cold Performance (CFP)</strong> <em>The reference technical journal for specifiers, designers and companies in Engineering...</em></p>



<p class="has-text-align-left wp-block-paragraph">. <a rel="noreferrer noopener" href="http://www.mapsec.fr/wp-content/uploads/2025/06/Equilibage_Hydraulique_MAPSEC.pdf" target="_blank"> The Equilog balancing method November 2014 – Download</a><br></p>