{"id":16686,"date":"2016-01-13T12:33:05","date_gmt":"2016-01-13T11:33:05","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16686"},"modified":"2026-06-25T12:38:40","modified_gmt":"2026-06-25T10:38:40","slug":"hydraulic-balancing-heating-free-diagnosis","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/en\/2016\/01\/13\/equilibrage-hydraulique-chauffage-diagnostic-gratuit\/","title":{"rendered":"Hydraulic balancing for heating"},"content":{"rendered":"<p data-start=\"550\" data-end=\"731\">Hydraulic balancing is an essential operation for ensuring thermal comfort and controlling energy consumption in collective heating systems.<\/p>\n<p data-start=\"733\" data-end=\"889\">For over 20 years, MAPSEC has been working on-site to diagnose, analyse, and optimise the hydraulic networks of residential and commercial buildings.<\/p>\n<p data-start=\"891\" data-end=\"1046\">Our approach is based on proven field expertise, a rigorous methodology, and tools developed specifically to ensure reliable adjustments.<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radiator\" src=\"http:\/\/media.xpair.com\/redac\/hydraulique\/chat-radiateur.jpg\" alt=\"radiator\" \/><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<div class=\"block full\">\n<div class=\"block-title\">\n<h5 style=\"text-align: left;\">L'\u00e9quilibrage hydraulique est essentiel pour garantir que le d\u00e9bit d'eau dans chaque circuit d'un syst\u00e8me de chauffage ou de refroidissement est correctement r\u00e9gl\u00e9 pour fournir le bon niveau de confort et d'efficacit\u00e9 \u00e9nerg\u00e9tique.<\/h5>\n<\/div>\n<hr \/>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><strong>The imbalance in collective heating circuits is very widespread<\/strong>.<br \/>\nIt consists of insufficient or excessive heating water circulation depending on the distribution zones.<br \/>\nIt manifests as complaints from some co-owners or tenants who are sometimes faced with rather low ambient temperatures, <strong>even while the rest of the building is properly or generously heated.<\/strong><br \/>\nRestoring homogenous heating water circulation allows for significant energy savings and re-establishes comfort in poorly irrigated areas.<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><span style=\"color: #ffffff;\">I<\/span><span style=\"color: #ffffff;\">I<\/span><\/p>\n<\/div>\n<div class=\"block full\"><\/div>\n<div class=\"block full\"><img decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Balancing of communal heating circuits\" src=\"http:\/\/media.xpair.com\/redac\/hydraulique\/equilibrage-mapsec.jpg\" alt=\"Balancing of communal heating circuits\" \/><\/div>\n<div class=\"block full\">\n<div class=\"block-title\">\n<h3 style=\"text-align: left;\"><\/h3>\n<h3 style=\"text-align: left;\"><span style=\"color: #ffffff;\">I<\/span><\/h3>\n<p>&nbsp;<\/p>\n<hr \/>\n<h5 style=\"text-align: left;\">Our on-site hydraulic balancing method<\/h5>\n<\/div>\n<hr \/>\n<p data-start=\"1865\" data-end=\"1917\">MAPSEC works directly on the installations.<\/p>\n<p data-start=\"1919\" data-end=\"1945\">Our protocol includes:<\/p>\n<h6 data-start=\"1947\" data-end=\"1973\">1\ufe0f\u20e3 Initial diagnosis<\/h6>\n<ul data-start=\"1974\" data-end=\"2078\">\n<li data-start=\"1974\" data-end=\"1993\">\n<p data-start=\"1976\" data-end=\"1993\">Network analysis<\/p>\n<\/li>\n<li data-start=\"1994\" data-end=\"2036\">\n<p data-start=\"1996\" data-end=\"2036\">Identification of balancing organs<\/p>\n<\/li>\n<li data-start=\"2037\" data-end=\"2078\">\n<p data-start=\"2039\" data-end=\"2078\">Temperature regime verification<\/p>\n<\/li>\n<\/ul>\n<h6 data-start=\"2080\" data-end=\"2107\">2\ufe0f\u20e3 Measurement campaign<\/h6>\n<ul data-start=\"2108\" data-end=\"2212\">\n<li data-start=\"2108\" data-end=\"2149\">\n<p data-start=\"2110\" data-end=\"2149\">Flow and return temperature measurements<\/p>\n<\/li>\n<li data-start=\"2150\" data-end=\"2170\">\n<p data-start=\"2152\" data-end=\"2170\">Variance analysis<\/p>\n<\/li>\n<li data-start=\"2171\" data-end=\"2212\">\n<p data-start=\"2173\" data-end=\"2212\">Detection of structural imbalances<\/p>\n<\/li>\n<\/ul>\n<h6 data-start=\"2214\" data-end=\"2256\">3. Gradual adjustment of settings<\/h6>\n<ul data-start=\"2257\" data-end=\"2364\">\n<li data-start=\"2257\" data-end=\"2298\">\n<p data-start=\"2259\" data-end=\"2298\">Adjustment of tees and balancing valves<\/p>\n<\/li>\n<li data-start=\"2299\" data-end=\"2327\">\n<p data-start=\"2301\" data-end=\"2327\">Column stabilisation<\/p>\n<\/li>\n<li data-start=\"2328\" data-end=\"2364\">\n<p data-start=\"2330\" data-end=\"2364\">Thermal ratio verification<\/p>\n<\/li>\n<\/ul>\n<h6 data-start=\"2366\" data-end=\"2396\">4\ufe0f\u20e3 Validation and control<\/h6>\n<ul data-start=\"2397\" data-end=\"2499\">\n<li data-start=\"2397\" data-end=\"2427\">\n<p data-start=\"2399\" data-end=\"2427\">Temperature Comparison<\/p>\n<\/li>\n<li data-start=\"2428\" data-end=\"2470\">\n<p data-start=\"2430\" data-end=\"2470\">Hydraulic coherence check<\/p>\n<\/li>\n<li data-start=\"2471\" data-end=\"2499\">\n<p data-start=\"2473\" data-end=\"2499\">Detailed technical report<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2501\" data-end=\"2676\">Our method is compatible with the requirements of ESCE standardised operations (BAR-SE-104 \/ BAT-SE-103) and falls within the scope of the associated technical recommendations.<\/p>\n<p style=\"text-align: left;\"><span style=\"color: #ffffff;\">\u00a0I<\/span><\/p>\n<hr \/>\n<p><strong>Field-based expertise<\/strong><\/p>\n<\/div>\n<div class=\"block full\">\n<hr \/>\n<p data-start=\"2722\" data-end=\"2901\">Unlike purely theoretical approaches based solely on flow rate calculations, our methodology relies on actual thermal observation of the network's behaviour.<\/p>\n<p data-start=\"2903\" data-end=\"2925\">We operate in:<\/p>\n<ul data-start=\"2927\" data-end=\"3079\">\n<li data-start=\"2927\" data-end=\"2949\">\n<p data-start=\"2929\" data-end=\"2949\">Risers<\/p>\n<\/li>\n<li data-start=\"2950\" data-end=\"2973\">\n<p data-start=\"2952\" data-end=\"2973\">Horizontal networks<\/p>\n<\/li>\n<li data-start=\"2974\" data-end=\"2998\">\n<p data-start=\"2976\" data-end=\"2998\">Underfloor heating<\/p>\n<\/li>\n<li data-start=\"2999\" data-end=\"3016\">\n<p data-start=\"3001\" data-end=\"3016\">Substations<\/p>\n<\/li>\n<li data-start=\"3017\" data-end=\"3054\">\n<p data-start=\"3019\" data-end=\"3054\">Residential apartment buildings<\/p>\n<\/li>\n<li data-start=\"3055\" data-end=\"3079\">\n<p data-start=\"3057\" data-end=\"3079\">Commercial buildings<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3081\" data-end=\"3188\">Each installation has specific hydraulic characteristics that require tailored analysis.<\/p>\n<p style=\"text-align: left;\"><span style=\"color: #ffffff;\">I<\/span><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\">\n<h5 style=\"text-align: left;\"><span style=\"color: #ffffff;\">I<\/span><\/h5>\n<hr \/>\n<h5 style=\"text-align: left;\">EQUILOG: the professional tool developed by MAPSEC<\/h5>\n<\/div>\n<hr \/>\n<p data-start=\"3202\" data-end=\"3254\">EQUILOG: the professional tool developed by MAPSEC<\/p>\n<p data-start=\"3256\" data-end=\"3380\">The experience gained in the field has led us to develop <strong data-start=\"3321\" data-end=\"3332\">EQUILOG<\/strong>, software dedicated to hydraulic balancing.<\/p>\n<p data-start=\"3382\" data-end=\"3398\">EQUILOG allows:<\/p>\n<ul data-start=\"3400\" data-end=\"3604\">\n<li data-start=\"3400\" data-end=\"3436\">\n<p data-start=\"3402\" data-end=\"3436\">Structured analysis of measures<\/p>\n<\/li>\n<li data-start=\"3437\" data-end=\"3476\">\n<p data-start=\"3439\" data-end=\"3476\">Assistance with adjusting components<\/p>\n<\/li>\n<li data-start=\"3477\" data-end=\"3529\">\n<p data-start=\"3479\" data-end=\"3529\">The automatic generation of technical reports<\/p>\n<\/li>\n<li data-start=\"3530\" data-end=\"3566\">\n<p data-start=\"3532\" data-end=\"3566\">Traceability of interventions<\/p>\n<\/li>\n<li data-start=\"3567\" data-end=\"3604\">\n<p data-start=\"3569\" data-end=\"3604\">The standardisation of procedures<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3606\" data-end=\"3734\">It is used by our teams and offered to professionals wishing to structure and secure their balancing operations.<\/p>\n<p data-start=\"3736\" data-end=\"3770\">\ud83d\udc49 <a href=\"https:\/\/mapsec.fr\/en\/equilog-2\/\">Discover EQUILOG software<\/a><\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><span style=\"color: #ffffff;\">\u00a0I<\/span><\/p>\n<\/div>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>L\u2019\u00e9quilibrage hydraulique est une op\u00e9ration essentielle pour garantir le confort thermique et ma\u00eetriser les consommations \u00e9nerg\u00e9tiques dans les installations de chauffage collectif. Depuis plus de 20<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16686","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/posts\/16686","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/comments?post=16686"}],"version-history":[{"count":2,"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/posts\/16686\/revisions"}],"predecessor-version":[{"id":17176,"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/posts\/16686\/revisions\/17176"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/media?parent=16686"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/categories?post=16686"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/en\/wp-json\/wp\/v2\/tags?post=16686"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}