{"id":16263,"date":"2015-09-01T17:36:27","date_gmt":"2015-09-01T16:36:27","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16263"},"modified":"2026-06-29T16:46:06","modified_gmt":"2026-06-29T14:46:06","slug":"todo-sobre-el-equilibrado-hidraulico-estatico-y-automatico","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/es\/2015\/09\/01\/tout-sur-lequilibrage-hydraulique-statiqueautomatique\/","title":{"rendered":"Todo sobre el balanceo hidr\u00e1ulico est\u00e1tico y autom\u00e1tico"},"content":{"rendered":"<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/mapsec.fr\/es\/contacto\/\" style=\"border-radius:2px\">pedir un presupuesto <\/a><\/div>\n<\/div>\n\n\n<p class=\"text-right small\" style=\"text-align: right;\">Por Patrick DELPECH \u2013 para la empresa MAPSEC \u2013 Marzo 2020<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><em>Para los responsables t\u00e9cnicos y decisores (promotores, administradores, etc.), las novedades del sector, las trampas a evitar y las condiciones para la correcta realizaci\u00f3n de los equilibrados hidr\u00e1ulicos y t\u00e9rmicos.<\/em><\/p>\n<p>Esta p\u00e1gina presenta los principios generales del balanceo hidr\u00e1ulico est\u00e1tico y autom\u00e1tico.<\/p>\n<p>Para conocer el m\u00e9todo MAPSEC aplicado a las redes de calefacci\u00f3n urbana, con diagn\u00f3stico, mediciones, ajustes, validaci\u00f3n y el m\u00e9todo EQUILOG, consulte nuestra p\u00e1gina principal dedicada a la\u2019<a href=\"https:\/\/mapsec.fr\/es\/2016\/01\/13\/equilibrado-hidraulico-calefaccion-diagnostico-gratuito\/\">equilibrado hidr\u00e1ulico calefacci\u00f3n central<\/a>.<\/p>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>LA PROBLEM\u00c1TICA<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">En un mismo circuito de calefacci\u00f3n, la presencia simult\u00e1nea de locales demasiado calientes y locales poco calientes es sintom\u00e1tica del defecto de equilibrio tan extendido.<br \/>Independientemente de su verdadero origen, ajuste hidr\u00e1ulico incorrecto, errores de dimensionamiento, operaci\u00f3n de aislamientos heterog\u00e9neos, etc., el problema puede corregirse ajustando v\u00e1lvulas de equilibrio, siempre que est\u00e9n correctamente distribuidas y sean suficientemente accesibles.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"T\u00e9 de ajuste y grifo volum\u00e9trico\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec1.jpg\" alt=\"\" width=\"529\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b01: Te de regulaci\u00f3n y grifo volum\u00e9trico <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">El ajuste a realizar consiste en limitar los grifos de las antenas favorecidas de tal manera que, al disminuir su caudal, aumente el de las antenas desfavorecidas.<\/p>\n<p>El principio de ajuste es, por tanto, f\u00e1cil de entender, pero su aplicaci\u00f3n mucho m\u00e1s delicada. Este documento detalla en qu\u00e9 condiciones se llevar\u00e1 a cabo correctamente una operaci\u00f3n de equilibrado hidr\u00e1ulico, especialmente en instalaciones existentes.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>EL AN\u00c1LISIS Y EL SABER HACER DE LAS OFICINAS DE ESTUDIOS<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">En t\u00e9rminos generales, una distribuci\u00f3n de agua de calefacci\u00f3n <strong>existente<\/strong> s\u00f3lo puede ser f\u00e1cilmente equilibrado si se han previsto grifos de equilibrado <u>accesibles<\/u>, fuera de los locales ocupados.<br \/>Si la instalaci\u00f3n no es demasiado antigua, esto normalmente ha sido previsto por las oficinas de ingenier\u00eda durante el dise\u00f1o de la instalaci\u00f3n mediante la instalaci\u00f3n de grifos llamados de 2<sup>en\u00e9simo<\/sup> nivel de equilibrado, situados en los s\u00f3tanos, los forjados sanitarios, o incluso los huecos de escalera y en cualquier caso en el exterior de los locales ocupados.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00e1lvulas de 2\u00ba nivel de equilibrado \" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec2.jpg\" alt=\"\" width=\"650\" height=\"357\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura 2: Grifos de 2<sup>en\u00e9simo<\/sup> nivel de equilibrio<\/em><\/p>\n<p class=\"text-justify push-top\">Los circuitos que solo tienen v\u00e1lvulas de equilibrado instaladas en los radiadores son dif\u00edciles de equilibrar, ya que el acceso simult\u00e1neo a todos los locales es muy dif\u00edcil de organizar cuando est\u00e1n ocupados.<\/p>\n<p>En esta situaci\u00f3n, corresponde hacer estudiar la distribuci\u00f3n por una oficina de estudios o un experto en equilibrado para determinar las posibilidades de instalaci\u00f3n de grifos accesibles de 2<sup>en\u00e9simo<\/sup> nivel.<br \/>Observemos que el equilibrio del circuito ser\u00e1 tanto m\u00e1s eficaz cuanto mayor sea el n\u00famero de emisores \u00abcontrolados\u00bb por las v\u00e1lvulas de 2<sup>en\u00e9simo<\/sup> El nivel ser\u00e1 moderado con un n\u00famero \u00f3ptimo de 5 a 10 unidades.<\/p>\n<p>En regla general, en las instalaciones existentes, el \u00fanico ajuste del 2<sup>en\u00e9simo<\/sup> El nivel de equilibrado (y de los niveles superiores) es suficiente para obtener un resultado correcto. Si, aun as\u00ed, persistieran des\u00f3rdenes en algunas antenas particulares, siempre ser\u00e1 posible proceder localmente a su equilibrado complementario. Este podr\u00e1 realizarse correctamente porque el grupo de emisores correspondiente habr\u00e1 sido previamente alimentado normalmente con el ajuste correcto de su grifo de 2<sup>en\u00e9simo<\/sup> nivel.<\/p>\n<p>Si la instalaci\u00f3n de v\u00e1lvulas de equilibrio de 2<sup>en\u00e9simo<\/sup> el nivel no es factible, habr\u00e1 que considerar un dif\u00edcil plan de acceso a todas las instalaciones.<br \/>Ya que vamos a optar por esta soluci\u00f3n costosa, podremos aprovechar para estudiar la instalaci\u00f3n de la \u00faltima generaci\u00f3n de grifos termost\u00e1ticos capaces de garantizar adem\u00e1s un equilibrado \u00abdin\u00e1mico\u00bb cuyo inter\u00e9s estudiaremos posteriormente.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00e1lvulas termost\u00e1ticas hidr\u00e1ulicamente din\u00e1micas Danfoss\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec3.jpg\" alt=\"\" width=\"300\" height=\"251\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura 3: V\u00e1lvulas termost\u00e1ticas hidr\u00e1ulicamente din\u00e1micas <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Finalmente, cabe se\u00f1alar que el ajuste de estas v\u00e1lvulas requiere, como en todas las v\u00e1lvulas de equilibrado, un ajuste hidr\u00e1ulico inicial preciso.<br \/>Como veremos posteriormente, si el balance se realiza ajustando caudales, su determinaci\u00f3n requerir\u00e1, en ausencia de referencias sobre instalaciones existentes, la intervenci\u00f3n de una oficina de estudios.<\/p>\n<p class=\"text-justify push-top\">\u00a0<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>EL AN\u00c1LISIS Y EL SABER HACER DE LOS INDUSTRIALES<\/h2>\n<\/div>\n<p class=\"text-justify push-top\"><em>Tres generaciones de grifos de equilibrado coexisten.<\/em><\/p>\n<p><strong>1<sup>\u00e8re<\/sup> generaci\u00f3n: Las v\u00e1lvulas o llaves de equilibrado est\u00e1ticas y no volum\u00e9tricas.<\/strong><br \/>Estos grifos no permiten medir los caudales en circulaci\u00f3n.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00e1lvulas de equilibrado no volum\u00e9tricas\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec18.jpg\" alt=\"\" width=\"650\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\"><em>Figura 4: V\u00e1lvulas de equilibrado no volum\u00e9tricas<\/em><\/p>\n<p class=\"text-justify push-top\">Dos m\u00e9todos permiten ajustarlos:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Simulaci\u00f3n hidr\u00e1ulica de distribuciones<\/li>\n<li class=\"pad5\">Uniformizaci\u00f3n de las temperaturas de retorno de las antenas a equilibrar<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">La simulaci\u00f3n hidr\u00e1ulica de las distribuciones supone el levantamiento detallado de la distribuci\u00f3n (longitudes de tramos, di\u00e1metros, etc.), la determinaci\u00f3n del comportamiento hidr\u00e1ulico de las v\u00e1lvulas instaladas y el c\u00e1lculo de los caudales a ajustar en cada antena.<br \/>En las instalaciones existentes, el conjunto de estos datos es complejo de reunir y las incertidumbres generadas limitan las posibilidades de obtener f\u00e1cilmente un buen resultado.<\/p>\n<p>Cuando las instalaciones est\u00e1n equipadas con grifos de este tipo, la mejor soluci\u00f3n consiste en proceder por <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/methode-dequilibrage-equilog\/\" target=\"_blank\" rel=\"noopener noreferrer\">unificaci\u00f3n de las temperaturas de retorno de agua de las antenas a equilibrar. <\/a><br \/>Este m\u00e9todo reciente se presentar\u00e1 m\u00e1s adelante.<\/p>\n<p><strong>2<sup>en\u00e9simo<\/sup> generaci\u00f3n: Las llaves o v\u00e1lvulas de equilibrado est\u00e1ticas y volum\u00e9tricas.<\/strong><br \/>Estos grifos permiten la medici\u00f3n de caudales en circulaci\u00f3n.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00e1lvulas de equilibrado volum\u00e9trico\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec5.jpg\" alt=\"\" width=\"451\" height=\"230\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b0 5: V\u00e1lvulas de equilibrado volum\u00e9trico <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> y <a class=\"bleu\" href=\"http:\/\/www.comap.fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">Compa<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Tres m\u00e9todos permiten resolverlos:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Simulaci\u00f3n hidr\u00e1ulica de distribuciones<\/li>\n<li class=\"pad5\">Reglaje y control de caudales mediante mediciones in situ<\/li>\n<li class=\"pad5\">Uniformizaci\u00f3n de las temperaturas de retorno del agua de las antenas a equilibrar<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Si se descarta la primera soluci\u00f3n dadas las dificultades que presenta en las instalaciones existentes, cabe se\u00f1alar que trabajar mediante el ajuste de caudales tambi\u00e9n requiere la intervenci\u00f3n de una oficina de estudios para determinar el caudal a ajustar en cada antena a equilibrar.<br \/>En las instalaciones existentes, la soluci\u00f3n m\u00e1s sencilla sigue siendo proceder mediante la uniformizaci\u00f3n de las temperaturas de retorno de agua.<\/p>\n<p><strong>3<sup>en\u00e9simo<\/sup> Generaci\u00f3n: Las v\u00e1lvulas de equilibrado din\u00e1micas<\/strong><br \/>La \u00faltima generaci\u00f3n de grifos de equilibrado, est\u00e1n destinados a ser instalados en <strong>los circuitos de flujo variable <\/strong>como los que est\u00e1n equipados con v\u00e1lvulas termost\u00e1ticas.<\/p>\n<p>Hay que distinguir 2 tipos de grifos:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Las v\u00e1lvulas de equilibrado \u00ab <em>reguladores de presi\u00f3n diferencial <\/em>\u00bb<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00e1lvulas reguladoras de presi\u00f3n diferencial\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec7.jpg\" alt=\"\" width=\"650\" height=\"207\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b06 : V\u00e1lvulas reguladoras de presi\u00f3n diferencial <a class=\"bleu\" href=\"http:\/\/honeywell.com\/country\/fr\/Pages\/home.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">Honeywell<\/a> y <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">En una instalaci\u00f3n equipada con v\u00e1lvulas termost\u00e1ticas (Rth), cuando estas se \u00abcierran\u00bb, el diferencial de presi\u00f3n de alimentaci\u00f3n (DP) de la red aumenta. Este aumento del DP se opone entonces al cierre de las Rth y conduce al aumento del caudal en los emisores cuyas v\u00e1lvulas termost\u00e1ticas a\u00fan no se han cerrado.<br \/>En esta situaci\u00f3n, la v\u00e1lvula reguladora de presi\u00f3n diferencial detecta el aumento de la DP y se \u00abcierra\u00bb para restablecerla.<\/p>\n<p>Ciertos modelos, como los de la foto de arriba, no son volum\u00e9tricos y por lo tanto no permiten la medici\u00f3n de caudales regulados. Su ajuste o el control de su ajuste deber\u00e1 realizarse mediante la medici\u00f3n de las temperaturas de retorno.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>en\u00e9simo<\/sup> tipo de v\u00e1lvulas de equilibrado din\u00e1micas: Las v\u00e1lvulas de equilibrado autom\u00e1ticas<\/strong> <em>(tambi\u00e9n llamados autoequilibrados o independientes de la presi\u00f3n de alimentaci\u00f3n, o reguladores de caudal)<\/em><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Grifos de equilibrado llamados \u00abautom\u00e1ticos\u00bb\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec8.jpg\" alt=\"\" width=\"250\" height=\"253\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n.\u00ba 7: V\u00e1lvulas de equilibrado llamadas \u00abautom\u00e1ticas\u00bb <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Estos grifos fueron dise\u00f1ados para permitir <strong>el ajuste de una \u00fanica unidad terminal<\/strong> como un intercambiador de calor para una CTA o un ventiloconvector.<br \/>Pueden ser motorizados y as\u00ed permitir la regulaci\u00f3n de la unidad en las mejores condiciones de funcionamiento hidr\u00e1ulico.<\/p>\n<p>A veces se utilizan para equilibrar antenas que tienen <strong>varios emisores equipados con v\u00e1lvulas de control de 2 v\u00edas<\/strong> tales como radiadores equipados con v\u00e1lvulas termost\u00e1ticas. Las v\u00e1lvulas de equilibrado autom\u00e1ticas sustituyen entonces a las v\u00e1lvulas reguladoras de presi\u00f3n diferencial previstas normalmente para este caso.<\/p>\n<p>Esta situaci\u00f3n no estaba prevista originalmente y no se menciona en las especificaciones t\u00e9cnicas de los fabricantes. De hecho, el funcionamiento de la v\u00e1lvula de equilibrado autom\u00e1tico no es del todo \u00f3ptimo en ese momento y, en esta situaci\u00f3n, se asemeja al de una v\u00e1lvula de equilibrado est\u00e1tico.<\/p>\n<p>Podremos estudiar este funcionamiento consultando el art\u00edculo: <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u00ab Equilibrio autom\u00e1tico, las condiciones del \u00e9xito \u00bb<\/a><\/p>\n<p>Se notar\u00e1 en los comentarios al final de este art\u00edculo la opini\u00f3n de 2 grandes fabricantes.<br \/>As\u00ed, IMI \u2013 Hydronic precisa:<br \/><em>\u00ab Sobre la instalaci\u00f3n de v\u00e1lvulas autom\u00e1ticas (PIBCV, Regulador de caudal en este caso) en redes de caudal variable (viviendas equipadas con v\u00e1lvulas termost\u00e1ticas, por ejemplo), nuestras posiciones de expertos o industriales especialistas en hidr\u00e1ulica nos imponen mantener un discurso t\u00e9cnicamente impecable. Aunque es innegable el desarrollo de la instalaci\u00f3n de PIBCV a la entrada de las viviendas, \u00e9ticamente no podemos fomentar esta pr\u00e1ctica. \u00bb<\/em><\/p>\n<p>M\u00e1s pragm\u00e1tico sobre el mismo tema, Oventrop indica <em>que si hay una concesi\u00f3n t\u00e9cnica en la hidr\u00e1ulica, el ajuste general obtenido con grifos autom\u00e1ticos es, de todos modos, mucho mejor que el obtenido con grifos est\u00e1ticos y grifos reguladores de presi\u00f3n, ya que estos \u00faltimos, en la mayor\u00eda de los casos, est\u00e1n poco o nada ajustados.<\/em><\/p>\n<p>Efectivamente, el ajuste de los grifos reguladores de presi\u00f3n diferencial a menudo deja que desear, especialmente en modelos que no son volum\u00e9tricos. Si no se trabaja mediante mediciones de temperatura de retorno, su ajuste solo podr\u00e1 realizarse sobre la base de un c\u00e1lculo hipot\u00e9tico de p\u00e9rdida de carga. Si se desea realizar el equilibrado mediante medici\u00f3n de caudal, es indispensable optar por modelos volum\u00e9tricos, y varias marcas ofrecen grifos volum\u00e9tricos adaptables.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00e1lvula volum\u00e9trica adaptada con v\u00e1lvula reguladora de presi\u00f3n diferencial Oventrop\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec17.jpg\" alt=\"\" width=\"513\" height=\"150\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b06 bis: V\u00e1lvula volum\u00e9trica adaptada con una v\u00e1lvula reguladora de presi\u00f3n diferencial <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Notemos, pues, sobre todo en conclusi\u00f3n, que no hay que confundir \u00ab instalaci\u00f3n de grifos \u00bb y \u00ab ajuste de grifos \u00bb, y esto sea cual sea la generaci\u00f3n de los modelos instalados.<\/p>\n<p>Al igual que las generaciones anteriores, los grifos de equilibrado din\u00e1mico deben someterse a un ajuste inicial riguroso. Este ajuste se puede realizar mediante simulaci\u00f3n y\/o mediciones de caudal y\/o medida de las temperaturas de retorno. El tema se desarrollar\u00e1 en el \u00a7 siguiente.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>LOS M\u00c9TODOS DE EQUILIBRADO<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">En las instalaciones de calefacci\u00f3n colectiva existentes, <strong>tres metodolog\u00edas <\/strong>de ajuste inicial de las v\u00e1lvulas de equilibrado se utilizan hoy en d\u00eda.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>1<sup>\u00e8re<\/sup> m\u00e9todo: Simulaci\u00f3n del comportamiento hidr\u00e1ulico de las redes<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Simulaci\u00f3n del comportamiento hidr\u00e1ulico de redes\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec9.jpg\" alt=\"\" width=\"492\" height=\"446\" \/><\/p>\n<p class=\"text-justify push-top\">En las instalaciones existentes, es te\u00f3ricamente posible realizar las mediciones necesarias para estimar los caudales y las p\u00e9rdidas de carga de los circuitos para deducir por c\u00e1lculo el preajuste de las v\u00e1lvulas de equilibrado. Sin embargo, se trata de una dif\u00edcil \u00abb\u00fasqueda del tesoro\u00bb, a menos que se disponga de planos de distribuci\u00f3n rara vez disponibles.<\/p>\n<p>Esta posibilidad particularmente desarrollada por <a class=\"bleu\" href=\"http:\/\/edipa.fr\/LibrairieTechnique\/Auteur?auteur=FRIDMANN%20Pierre&amp;page=1\" target=\"_blank\" rel=\"noopener noreferrer\">Se\u00f1or Pierre Fridmann<\/a> necesita la posibilidad de poder verificar posteriormente el resultado de todos los preajustes realizados, ya sea mediante la medici\u00f3n de caudales o mediante la medici\u00f3n de las temperaturas de retorno de agua.<\/p>\n<p>Este m\u00e9todo se refiere m\u00e1s bien a instalaciones nuevas o recientes que a\u00fan no presentan incrustaciones imprevistas y sobre las cuales se dispone de todos los datos de c\u00e1lculo necesarios.<br \/>En particular, puede utilizarse para determinar las diferencias de presi\u00f3n que deben ajustarse en las v\u00e1lvulas \u00abreguladoras de presi\u00f3n diferencial\u00bb que tienen graduaciones de ajuste en unidades de presi\u00f3n.<br \/>El resultado de la simulaci\u00f3n permite hacer un preajuste de las v\u00e1lvulas antes de que los caudales de agua o las temperaturas de retorno de agua efectivamente obtenidos se controlen y ajusten en obra.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>en\u00e9simo<\/sup> m\u00e9todo: C\u00e1lculo, ajuste y control de los flujos a transportar<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">La metodolog\u00eda consiste en calcular y ajustar los caudales a transportar. Requiere, por supuesto, la presencia de v\u00e1lvulas de control de flujo, tambi\u00e9n llamadas \u00abvolum\u00e9tricas\u00bb, est\u00e1ticas o din\u00e1micas, que permiten la medici\u00f3n de los caudales.<br \/>Por lo tanto, no es aplicable a <strong>grifos no volum\u00e9tricos<\/strong> tales como los simples grifos de ajuste instalados en la salida de los radiadores, pero tambi\u00e9n en el pie de la columna y, sobre todo, en el retorno de los bucles de calefacci\u00f3n por suelo radiante.<\/p>\n<p>Recordemos tambi\u00e9n que algunos grifos reguladores de presi\u00f3n diferencial no son volum\u00e9tricos. Su ajuste o el control de su ajuste deber\u00e1 efectuarse \u00fanicamente midiendo las temperaturas de retorno.<\/p>\n<p>En las instalaciones existentes, para la determinaci\u00f3n de los caudales a regular, una oficina de estudios deber\u00e1 realizar las mediciones necesarias para la estimaci\u00f3n de las p\u00e9rdidas correspondientes a cada una de las antenas de calefacci\u00f3n a tratar.<br \/>Para ello, deber\u00e1 calcular las p\u00e9rdidas de los locales est\u00e1ndar y de los locales particulares (debajo de la terraza, contra el hastial, etc.). Luego, lo que a menudo es muy delicado, deber\u00e1 asignarlas correctamente a cada una de las antenas a ajustar.<\/p>\n<p>El ajuste de los caudales requiere el uso de una maleta de medici\u00f3n y, si los grifos no son din\u00e1micos, la utilizaci\u00f3n de una metodolog\u00eda particular.<br \/>Se podr\u00e1 adquirir uno de estos m\u00e9todos en <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-debit.htm\" target=\"_blank\" rel=\"noopener noreferrer\">l'Eformation Xpair<\/a> o sobre <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulador.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Control de flujo\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec10.jpg\" alt=\"\" width=\"551\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b09: Control de flujo Fuente <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> y malet\u00edn de medici\u00f3n <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Si los grifos de ajuste son<strong> de tipo din\u00e1mico <\/strong>el ajuste de los caudales puede realizarse m\u00e1s f\u00e1cilmente, sin necesidad de utilizar un m\u00e9todo particular, excepto la verificaci\u00f3n de que la llave m\u00e1s desfavorable dispone de una presi\u00f3n diferencial de alimentaci\u00f3n suficiente.<\/p>\n<p>Sobre ciertos grifos din\u00e1micos graduados en caudal, el preajuste podr\u00e1 realizarse sin medici\u00f3n, pero esto no eximir\u00e1 de la medici\u00f3n final de los caudales obtenidos cuando todas las v\u00e1lvulas hayan sido preajustadas.<br \/>En los modelos que no est\u00e1n graduados en caudal, especialmente en las v\u00e1lvulas reguladoras de presi\u00f3n diferencial, el ajuste de los caudales no podr\u00e1 realizarse sin su medici\u00f3n efectiva (si son, por otra parte, de tipo volum\u00e9trico).<\/p>\n<p>Cuando todas las v\u00e1lvulas din\u00e1micas se hayan regulado o preajustado, y si son de tipo volum\u00e9trico, un equilibrado serio finalizar\u00e1 con la medici\u00f3n de todos los caudales en circulaci\u00f3n para asegurarse de que las interacciones hidr\u00e1ulicas entre las antenas se han tenido en cuenta.<br \/>Recordemos, de hecho, que basta con unas pocas antenas desfavorecidas para tener que sobrecalentar el resto de la distribuci\u00f3n, y el comportamiento hidr\u00e1ulico de los circuitos, especialmente los existentes, a menudo reserva muchas sorpresas.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>3<sup>en\u00e9simo<\/sup> m\u00e9todo: Medici\u00f3n y estandarizaci\u00f3n en temporada de calefacci\u00f3n de las temperaturas de retorno de agua<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Esta soluci\u00f3n m\u00e1s reciente, denominada \u00abm\u00e9todo EQUILOG\u00bb, consiste, con la instalaci\u00f3n de calefacci\u00f3n en funcionamiento y la temperatura de impulsi\u00f3n estabilizada, en <strong>medir las temperaturas de retorno de agua <\/strong>des antenas para equilibrarlas y uniformizarlas de tal manera que todas las antenas a ajustar est\u00e9n \u00abtan calientes\u00bb unas que otras.<\/p>\n<p>Aparentemente \u00absimplista\u00bb, el procedimiento ha sido y sigue siendo objeto de cr\u00edticas muy naturales por parte de sus competidores. Se podr\u00e1 leer sobre ello <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-hydraulique-methode-simple.htm\" target=\"_blank\" rel=\"noopener\">\u00abEquilibrado hidr\u00e1ulico: novedades para un m\u00e9todo simple. <\/a>Pero se puede constatar que en varios cientos de sitios, m\u00e1s de 80000 equivalentes viviendas han sido hasta la fecha tratados en buenas condiciones de rentabilidad.<\/p>\n<p>Tras el equilibrio, las antenas presentar\u00e1n temperaturas de retorno y diferencias de temperatura de ida\/vuelta comparables. <em>(*)<\/em>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Uniformizaci\u00f3n de las temperaturas de agua de un circuito de calefacci\u00f3n\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec12.gif\" alt=\"\" width=\"573\" height=\"229\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b0 11: Uniformizaci\u00f3n(*) de las temperaturas de agua de un circuito de calefacci\u00f3n<\/em><\/p>\n<p class=\"text-justify push-top\"><em>(*) Cuando la distribuci\u00f3n hidr\u00e1ulica lo permite, por supuesto, es posible ajustar temperaturas de agua diferenciadas en cada salida, para tener en cuenta operaciones locales de aislamiento. <\/em><br \/><em>Sin embargo, se observa que en los edificios que han sido objeto de renovaciones t\u00e9rmicas homog\u00e9neas (reemplazo de todas las carpinter\u00edas, aislamiento de todas las paredes verticales exteriores), el equilibrio <u>inicial o posterior<\/u> realizado por la uniformizaci\u00f3n de las temperaturas del agua es suficiente para obtener un buen resultado. <\/em><br \/><em>El ajuste de la potencia de calefacci\u00f3n se puede realizar a continuaci\u00f3n mediante un simple ajuste de la temperatura del agua de salida de la sala de calderas (ajuste de la curva de calefacci\u00f3n).<\/em><\/p>\n<p>El procedimiento aplicable a todo tipo de grifos, pudo ser optimizado gracias a los avances realizados en el campo de la termometr\u00eda infrarroja y a las investigaciones efectuadas por el GMTI94 \u2013 GEFEn.<br \/>Podremos estudiar su principio sobre <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-temp.htm\" target=\"_blank\" rel=\"noopener noreferrer\">l'Eformation Xpair<\/a> o sobre <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulador<\/a>.<\/p>\n<p>La principal ventaja de la metodolog\u00eda es poder prescindir de todos los c\u00e1lculos de p\u00e9rdidas o de mediciones de instalaci\u00f3n en las redes con un tama\u00f1o normal. Por ello, es especialmente adecuada para circuitos existentes en los que los archivos rara vez est\u00e1n disponibles.<\/p>\n<p>Implementado experimentalmente en los a\u00f1os 2000, este procedimiento ha sido patentado en Francia y recientemente en 15 pa\u00edses europeos.<br \/>El m\u00e9todo \u00abEQUILOG\u00bb es implementado en particular por <em>\u00ab <\/em><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><em>la sociedad MAPSEC <\/em><\/strong><\/a><em>\u00bb(*) <\/em>para diversas empresas de operaci\u00f3n e instalaci\u00f3n (Dalkia, Cofely-Soccram, Idex, etc.).<br \/><em>MAPSEC 80 rue de Paris 93100 Montreuil Tel: 01 48 59 06 05 \u2013 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr<\/a><\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Circulador\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec11.jpg\" alt=\"\" width=\"250\" height=\"187\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura n\u00b010: Control de temperatura de la fuente de agua <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/\" target=\"_blank\" rel=\"noopener noreferrer\">Mapa<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Notemos finalmente que en <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">el art\u00edculo dedicado a las v\u00e1lvulas de equilibrado din\u00e1micas<\/a> evocado en el \u00a7 anterior, el ingeniero representante de Oventrop indica en los comentarios al final del expediente.<br \/><em>\u00abPara lo existente, el equilibrio mediante la uniformizaci\u00f3n de las temperaturas de retorno es tambi\u00e9n, en mi opini\u00f3n, el mejor m\u00e9todo, si la ca\u00edda de temperatura retenida es la correcta.<br \/>A pesar de todo, este m\u00e9todo consume mucho tiempo y es dif\u00edcilmente aceptado por los instaladores de viviendas especialistas cuando debe realizarse manualmente.<br \/>Existen grifos que hacen esto autom\u00e1ticamente, pero el precio no es el mismo.\u00bb<\/em><\/p>\n<p>Efectivamente, la ecualizaci\u00f3n mediante la uniformizaci\u00f3n de las temperaturas de retorno sol\u00eda requerir largos tiempos de espera para la estabilizaci\u00f3n t\u00e9rmica, pero los \u00faltimos avances logrados permiten ahora liberarse de ello y la duraci\u00f3n de las operaciones se ha vuelto muy competitiva.<\/p>\n<p>Por otra parte, efectivamente se podr\u00eda contemplar la realizaci\u00f3n y el mantenimiento a lo largo del tiempo de equilibrados mediante la uniformizaci\u00f3n de las temperaturas de retorno de forma autom\u00e1tica. Pero, en el estado actual de la tecnolog\u00eda, esto requerir\u00eda la instalaci\u00f3n y la alimentaci\u00f3n el\u00e9ctrica de v\u00e1lvulas de equilibrado autom\u00e1ticas motorizadas y conectadas a un aut\u00f3mata o a un sistema de gesti\u00f3n t\u00e9cnica centralizada de edificios (GTB).<br \/>Desde un punto de vista econ\u00f3mico esto sigue siendo dif\u00edcilmente imaginable por el momento, al menos en las instalaciones existentes.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>EL AN\u00c1LISIS Y EL SABER HACER DE LOS INSTALADORES<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Es fundamental distinguir claramente las actividades de desincrustaci\u00f3n (cuando sea necesario) y las de instalaci\u00f3n de v\u00e1lvulas de equilibrado, de las de su ajuste inicial propiamente dicho.<\/p>\n<p>De hecho, independientemente del tipo de grifo, es tentador para una empresa de instalaci\u00f3n o desincrustaci\u00f3n incluir en su propuesta el puesto de puesta en marcha sin ser siempre capaz de definir todos sus par\u00e1metros.<\/p>\n<p>Evidentemente se puede imaginar que una misma empresa pueda responder a un conjunto de operaciones de reequilibrio, pero entonces debe contar con equipos de saberes hacer muy diferentes, pr\u00e1cticos y te\u00f3ricos.<\/p>\n<p>En general, por lo tanto, ser\u00e1 necesario ser extremadamente prudente en la elecci\u00f3n de una empresa candidata a una acci\u00f3n de equilibrado. Se trata de una especialidad t\u00e9cnica dif\u00edcil y los malos resultados son numerosos porque la verificaci\u00f3n de la calidad del trabajo realizado es dif\u00edcil de llevar a cabo.<\/p>\n<p>Incluso si esto implicara un coste adicional, no dudaremos en separar las intervenciones de tal manera que las fases de estudio y\/o desarrollo sean realizadas por especialistas en la materia.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radiador\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec13.jpg\" alt=\"\" width=\"450\" height=\"173\" \/><\/p>\n<p class=\"text-justify push-top\">Una buena forma de selecci\u00f3n ser\u00e1 pedir, durante la consulta, el tipo de m\u00e9todo que se utilizar\u00e1 y asegurarse de que se especifiquen los datos que se devolver\u00e1n despu\u00e9s de la operaci\u00f3n.<br \/>Cualquier duda o vacilaci\u00f3n en las respuestas proporcionadas sobre uno u otro de estos 2 puntos ser\u00e1, sin duda, signo de una actuaci\u00f3n mal dominada.<\/p>\n<p>Si la empresa trabaja por medidor de flujo o por simulaci\u00f3n hidr\u00e1ulica, se podr\u00e1 solicitar que la propuesta incluya la entrega final:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">De la descalculaci\u00f3n detallada de las p\u00e9rdidas <strong>en correspondencia con cada grifo a tratar<\/strong> y que ha llevado al establecimiento de los caudales a liquidar. De este modo, se podr\u00e1 garantizar que los caudales previstos no son el resultado de estimaciones burdas.<\/li>\n<li class=\"pad5\">De una rejilla <strong>certificada<\/strong> caudales medidos <u>al final del ajuste de todos los grifos<\/u> (y no se limitarse a la parrilla de caudales te\u00f3ricamente previstos). As\u00ed se podr\u00e1 asegurar que las interacciones hidr\u00e1ulicas entre las antenas a ajustar se han tenido en cuenta efectivamente y, si es \u00fatil, poder controlarlo.<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Si la empresa trabaja por medida de las temperaturas de retorno, se podr\u00e1 solicitar que la propuesta incluya:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Algunas referencias correspondientes o, mejor a\u00fan, la comunicaci\u00f3n de al menos un informe detallado de una operaci\u00f3n realizada previamente. Esto permitir\u00e1 asegurarse de la experiencia del candidato, ya que si bien el principio del m\u00e9todo es antiguo, realmente solo se ha dominado en los \u00faltimos tiempos.<\/li>\n<li class=\"pad5\">La restituci\u00f3n de un gr\u00e1fico <strong>certificado, completo y detallado<\/strong> temperaturas de retorno medidas,<strong> antes y despu\u00e9s del balance<\/strong>, con la indicaci\u00f3n de las temperaturas de salida estabilizadas para las cuales se realizaron estas mediciones. Esto permitir\u00e1 asegurar la calidad del trabajo realizado.<\/li>\n<\/ul>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>RENTABILIDAD Y AHORRO ENERG\u00c9TICO<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">No es f\u00e1cil predecir el ahorro de energ\u00eda que se puede esperar de una operaci\u00f3n de equilibrado.<br \/>De hecho, si en la hip\u00f3tesis de un equilibrio perfectamente realizado, se puede estimar a partir de una cartograf\u00eda de las temperaturas ambientales iniciales, esta es en realidad muy dif\u00edcil de interpretar.<br \/>En cualquier caso, si se opta por esta v\u00eda de estimaci\u00f3n, hay que basarse en registros realizados en per\u00edodos muy fr\u00edos y en ausencia de cualquier aporte gratuito (insolaci\u00f3n, aparatos el\u00e9ctricos, etc.) y no en mediciones instant\u00e1neas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Ejemplo de registro de temperaturas ambientales perturbadas por aportaciones gratuitas\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec15.jpg\" alt=\"\" width=\"400\" height=\"235\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Fig. 15: Ejemplo de registro de temperaturas ambientales perturbadas por las ganancias gratuitas<\/em><\/p>\n<p class=\"text-justify push-top\">Pero a\u00fan m\u00e1s delicado es tener en cuenta la instalaci\u00f3n de las v\u00e1lvulas de equilibrado que realmente se podr\u00e1n regular. De hecho, en las instalaciones de calefacci\u00f3n existentes, el equilibrado generalmente solo se realiza en las v\u00e1lvulas accesibles de 2<sup>en\u00e9simo<\/sup> nivel (ver 2<sup>en\u00e9simo<\/sup> \u00a7). En consecuencia, la buena o mala implantaci\u00f3n de este 2<sup>en\u00e9simo<\/sup> el nivel es un par\u00e1metro esencial para la estimaci\u00f3n del ahorro de energ\u00eda esperado.<\/p>\n<p>Sobre este punto la empresa MAPSEC utiliza una metodolog\u00eda denominada <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/ecomapsec\/\" target=\"_blank\" rel=\"noopener noreferrer\">REQUILOG<\/a> que le permite, a partir de un mapeo de las temperaturas de retorno de agua medidas a la altura de los grifos a ajustar, evaluar la magnitud del desequilibrio que efectivamente podr\u00e1 ser tratado.<br \/>Adem\u00e1s, siempre que es posible, las operaciones de equilibrado que se le encomiendan van precedidas de una operaci\u00f3n de diagn\u00f3stico que incluye esta evaluaci\u00f3n, lo que permite al responsable de la toma de decisiones evaluar mejor el inter\u00e9s de proceder o no a la operaci\u00f3n.<\/p>\n<p>Finalmente, cabe se\u00f1alar que el ahorro de energ\u00eda derivado de una operaci\u00f3n de equilibrado requerir\u00e1 la posterior intervenci\u00f3n del t\u00e9cnico encargado de ajustar su regulaci\u00f3n.<br \/>En efecto, si el equilibrio consistiera finalmente en devolver a los locales inicialmente menos calentados a la situaci\u00f3n de los mejor calentados, no seria un ahorro de energ\u00eda lo que se obtendr\u00eda...<\/p>\n<p>En general, parece que el % medio del ahorro energ\u00e9tico tras el reequilibrio de las distribuciones de calefacci\u00f3n es de unos 7%, con un periodo de amortizaci\u00f3n de entre 2 y 3 a\u00f1os, si el circuito no requiere, o requiere muy pocas, sustituciones de v\u00e1lvulas.<\/p>\n<p>Hasta diciembre de 2014, estas operaciones pod\u00edan integrarse en el programa de Certificados de Ahorro Energ\u00e9tico con un porcentaje fijo de ahorro energ\u00e9tico del 10%.<br \/>Las fichas BAR y BAT SE 04 correspondientes est\u00e1n actualmente en proceso de modificaci\u00f3n. Deber\u00edan reaparecer con otras designaciones en la pr\u00f3xima orden ministerial dedicada a los CEE.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"tocado ECO\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec14.jpg\" alt=\"\" width=\"250\" height=\"180\" \/><\/p>\n<p class=\"text-justify push-top\">Finalmente, para concluir, una certeza: las operaciones de equilibrado son, en general, perfectamente rentables si se realizan con rigor.<\/p>\n<p>La mejor prueba es el trabajo realizado por el servicio de equilibrio de la empresa Dalkia en IdF(*) creado hace unos diez a\u00f1os para explotar el m\u00e9todo EQUILOG y actualmente gestionado por el Sr. Christophe Tillay.<br \/>Se podr\u00e1 leer en Xpair el resumen de una de sus realizaciones en el art\u00edculo <a class=\"bleu\" href=\"http:\/\/conseils.xpair.com\/actualite_experts\/exemple-operation-equilibrage-egalisation-temperatures-retour.htm\" target=\"_blank\" rel=\"noopener noreferrer\">\u00ab Operaci\u00f3n de equilibrado por uniformizaci\u00f3n de las temperaturas de retorno \u00bb.<\/a><\/p>\n<p><em>(*) Dalkia \u00cele-de-France, Service \u00c9quilibrage, 28 Boulevard de Pesaro, 92 751 NANTERRE CEDEX Tel: 01 55 67 68 97 <\/em><\/p>\n<p>Los cientos de operaciones de equilibrio realizadas por este servicio se han llevado a cabo exclusivamente en conjuntos inmobiliarios gestionados por la sociedad en el marco de contratos MF (mercado a tanto alzado) o MT (mercado de temperatura). En este tipo de contratos, que no est\u00e1n suficientemente extendidos, el cliente paga anualmente al explotador una suma a tanto alzado (o corregida por los DJU) a cambio de la garant\u00eda de una calefacci\u00f3n \u00f3ptima.<\/p>\n<p>El suministro de combustible recae entonces enteramente en la sociedad explotadora. Su principal inter\u00e9s es, por lo tanto, reducirlo dentro de los l\u00edmites de una calefacci\u00f3n correcta para el cliente, ya que la totalidad de los ahorros de energ\u00eda realizados le revertir\u00e1n.<\/p>\n<p>Este tipo de asunto anima evidentemente al proveedor a la mejor gesti\u00f3n posible de la instalaci\u00f3n y a asignarle sus mejores equipos. Desde un punto de vista ecol\u00f3gico, la situaci\u00f3n es as\u00ed \u00f3ptima.<br \/>Por su parte, sin coste adicional particular, el cliente tiene la garant\u00eda de una calefacci\u00f3n duradera y bien regulada y la de recuperar, al final de contratos generalmente de 8 a\u00f1os, una instalaci\u00f3n tan bien mantenida como sea posible.<\/p>\n<p>Los equilibrados realizados por el servicio de Equilibrado de Dalkia IdF se financiaron, por lo tanto, con fondos propios y se amortizaron en pocos a\u00f1os con los ahorros energ\u00e9ticos generados.<br \/>El mantenimiento y desarrollo de este servicio durante 10 a\u00f1os es una prueba innegable de la buena rentabilidad de este tipo de operaciones.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Gr\u00e1fico de balance\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec16.jpg\" alt=\"\" width=\"400\" height=\"250\" \/><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\" style=\"text-align: left;\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>CONCLUSI\u00d3N<\/h2>\n<\/div>\n<p class=\"text-justify push-top\" style=\"text-align: left;\">La reducci\u00f3n del consumo energ\u00e9tico de nuestra red de calefacci\u00f3n colectiva existente se basa en el aislamiento, el ajuste adecuado de las combustiones, la regulaci\u00f3n y el equilibrado.<\/p>\n<p style=\"text-align: left;\">A pesar de su gran influencia en el ajuste de la regulaci\u00f3n y el rendimiento de las calderas de condensaci\u00f3n (y de la cogeneraci\u00f3n), el \u00faltimo punto era hasta ahora el eslab\u00f3n d\u00e9bil.<\/p>\n<p style=\"text-align: left;\">Tras una largu\u00edsima pausa, nunca el problema hab\u00eda estado tan de actualidad.<\/p>\n<p style=\"text-align: left;\">Los avances recientes en el campo de la tornecer\u00eda y el desarrollo deber\u00edan permitir un mejor aprovechamiento de uno de los yacimientos de ahorro de energ\u00eda m\u00e1s importantes que quedan disponibles.<\/p>\n<\/div>\n<h4 class=\"text-primary push-top\" style=\"text-align: left;\"><strong>FUENTES Y ENLACES<\/strong><\/h4>\n<ul class=\"push-top\">\n<li class=\"pad10\" style=\"text-align: left;\">PUESTA A PUNTO: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/puesta-a-punto\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mise-au-point<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">PUESTA EN MARCHA DE HVAC <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/comisionamiento\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/commissioning<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">AUDITAR TERRENO: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/auditoria\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/auditor\u00eda<\/a><\/li>\n<li style=\"text-align: left;\">PRUEBA DE ESTANQUEIDAD Conductos de aire:\u00a0<a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/medicion-de-la-estanqueidad-al-aire-de-las-redes-de-ventilacion<\/a><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/es\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">s<\/a><\/li>\n<li style=\"text-align: left;\">SIMULADOR Aprender a equilibrar: <a href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564\" target=\"_blank\" rel=\"noopener\">www.edipa.fr\/LibrairieTechnique\/Details\/564<\/a><\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Par Patrick DELPECH &#8211; pour la soci\u00e9t\u00e9 MAPSEC &#8211; Mars 2020 Pour les responsables techniques et d\u00e9cideurs (maitres d\u2019ouvrage, syndic, etc.), les nouveaut\u00e9s du secteur, les<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16263","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/posts\/16263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/comments?post=16263"}],"version-history":[{"count":4,"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/posts\/16263\/revisions"}],"predecessor-version":[{"id":17284,"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/posts\/16263\/revisions\/17284"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/media?parent=16263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/categories?post=16263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/es\/wp-json\/wp\/v2\/tags?post=16263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}