{"id":16263,"date":"2015-09-01T17:36:27","date_gmt":"2015-09-01T16:36:27","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16263"},"modified":"2026-06-29T16:46:06","modified_gmt":"2026-06-29T14:46:06","slug":"koik-mis-puudutab-automaatset-staatilist-hudraulilist-tasakaalustamist","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/et\/2015\/09\/01\/tout-sur-lequilibrage-hydraulique-statiqueautomatique\/","title":{"rendered":"K\u00f5ik, mida vaja teada staatilise ja automaatse h\u00fcdraulilise tasakaalustamise kohta"},"content":{"rendered":"<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/mapsec.fr\/et\/contact\/\" style=\"border-radius:2px\">hinnapakkumist k\u00fcsida <\/a><\/div>\n<\/div>\n\n\n<p class=\"text-right small\" style=\"text-align: right;\">Autor: Patrick DELPECH \u2013 ettev\u00f5tte MAPSEC nimel \u2013 m\u00e4rts 2020<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><em>Tehnilistele juhtidele ja otsustajatele (ehituse tellijad, korteri\u00fchistute esindajad jne) on siin esitatud valdkonna uuendused, v\u00e4ltida tuleks l\u00f5ksud ning h\u00fcdraulilise ja soojusliku tasakaalustamise edukaks l\u00e4biviimiseks vajalikud tingimused.<\/em><\/p>\n<p>K\u00e4esoleval lehel tutvustatakse staatilise ja automaatse h\u00fcdraulilise tasakaalustamise \u00fcldp\u00f5him\u00f5tteid.<\/p>\n<p>Et tutvuda MAPSEC-meetodiga, mida rakendatakse \u00fchisk\u00fcttes\u00fcsteemides, sealhulgas diagnostika, m\u00f5\u00f5tmised, reguleerimine, valideerimine ja EQUILOG-meetod, k\u00fclastage meie pealehte, mis on p\u00fchendatud\u2019<a href=\"https:\/\/mapsec.fr\/et\/2016\/01\/13\/kutte-susteemi-hudrauliline-tasakaalustamine-tasuta-diagnoos\/\">kollektiivse k\u00fcttes\u00fcsteemi h\u00fcdrauliline tasakaalustamine<\/a>.<\/p>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>PROBLEEM<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Kui \u00fches ja samas k\u00fcttes\u00fcsteemis esinevad \u00fcheaegselt nii liiga soojad kui ka liiga jahedad ruumid, on see m\u00e4rk laialt levinud tasakaalustamatuse probleemist.<br \/>S\u00f5ltumata probleemi tegelikust p\u00f5hjusest \u2013 olgu see siis h\u00fcdrauliline valereguleerimine, m\u00f5\u00f5tmete valesti arvutamine, eba\u00fchtlane isolatsioon jne \u2013 on seda v\u00f5imalik lahendada nn tasakaalustusventiilide reguleerimise abil, eeldusel, et need on \u00f5igesti paigutatud ja piisavalt ligip\u00e4\u00e4setavad.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Reguleerimis-T-liitmik ja voolukraan\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec1.jpg\" alt=\"\" width=\"529\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 1: Reguleerimist\u00fckk ja voolukraan <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Vajalik reguleerimine seisneb selles, et eelistatud antennide ventiile tuleb sulgeda nii, et nende vooluhulga v\u00e4henedes suureneks ebasoodsas olukorras olevate antennide vooluhulk.<\/p>\n<p>Reguleerimise p\u00f5him\u00f5te on seega lihtne m\u00f5ista, kuid selle rakendamine on palju keerulisem. K\u00e4esolevas artiklis selgitatakse, millistel tingimustel toimub h\u00fcdrauliline tasakaalustamine n\u00f5uetekohaselt, eriti olemasolevates s\u00fcsteemides.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>PROJEKTEERIMISB\u00dcROODE ANAL\u00dc\u00dcS JA OSKUSTEADMISED<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">\u00dcldiselt v\u00f5ib \u00f6elda, et k\u00fcttevee jaotuss\u00fcsteem <strong>olemasolev<\/strong> seda saab h\u00f5lpsasti tasakaalustada ainult juhul, kui on paigaldatud tasakaalustusventiilid <u>k\u00e4ttesaadavad<\/u>, v\u00e4ljaspool kasutatavaid ruume.<br \/>Kui rajatis ei ole liiga vana, on projekteerimisb\u00fcrood seda tavaliselt rajatise projekteerimisel ette n\u00e4inud, paigaldades nn 2-klapid<sup>\u00e8me<\/sup> tasakaalustustasandil, mis asuvad keldrites, tehnilistes ruumides, isegi trepikodades ja igal juhul v\u00e4ljaspool kasutatavaid ruume.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Teise taseme tasakaalustusventiilid \" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec2.jpg\" alt=\"\" width=\"650\" height=\"357\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis 2: 2 kraani<sup>\u00e8me<\/sup> tasakaalustamise tase<\/em><\/p>\n<p class=\"text-justify push-top\">S\u00fcsteeme, milles on radiaatoritele paigaldatud ainult tasakaalustusventiilid, on raske tasakaalustada, kuna k\u00f5igile ruumidele samaaegset juurdep\u00e4\u00e4su on v\u00e4ga raske korraldada, kui need on h\u00f5ivatud.<\/p>\n<p>Sellises olukorras tuleks lasta projekteerimisb\u00fcrool v\u00f5i tasakaalustamise eksperdil s\u00fcsteemi l\u00e4bi vaadata, et selgitada v\u00e4lja v\u00f5imalused paigaldada 2 juurdep\u00e4\u00e4setavad kraanid<sup>\u00e8me<\/sup> tase.<br \/>Tuleb m\u00e4rkida, et vooluahela tasakaalustamine on seda t\u00f5husam, mida rohkem on 2. kraanidega \u00abkontrollitavaid\u00bb saatjaid<sup>\u00e8me<\/sup> Raskusaste on m\u00f5\u00f5dukas, optimaalne arv on 5\u201310 \u00fchikut.<\/p>\n<p>Reeglina on olemasolevates s\u00fcsteemides ainus 2. seadistus<sup>\u00e8me<\/sup> tasakaalustustase (ja sellest k\u00f5rgemad tasemed) on piisav \u00f5ige tulemuse saavutamiseks. Kui m\u00f5nel konkreetsel antennil peaks siiski h\u00e4ireid esinema, on alati v\u00f5imalik kohapeal t\u00e4iendavat tasakaalustamist teostada. Seda on v\u00f5imalik korrektselt teostada, kuna vastavat saatjar\u00fchma on eelnevalt \u00f5igesti toidetud, t\u00e4nu selle 2-kraani \u00f5igele seadistusele<sup>\u00e8me<\/sup> tase.<\/p>\n<p>Kui paigaldatakse 2-<sup>\u00e8me<\/sup> Kui seda taset ei ole v\u00f5imalik saavutada, tuleb kindlasti kaaluda k\u00f5igile ruumidele juurdep\u00e4\u00e4su tagamise keerulist kava.<br \/>Kui juba otsustame selle kuluka lahenduse kasuks, v\u00f5iksime samal ajal uurida v\u00f5imalust paigaldada viimase p\u00f5lvkonna termostaatventiilid, mis suudavad tagada ka \u00abd\u00fcnaamilise\u00bb tasakaalustamise, mille eeliseid uurime hiljem.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Danfoss\u2019i h\u00fcdrauliliselt d\u00fcnaamilised termostaatventiilid\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec3.jpg\" alt=\"\" width=\"300\" height=\"251\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis 3: H\u00fcdrauliliselt d\u00fcnaamilised termostaatventiilid <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">L\u00f5petuseks tuleb m\u00e4rkida, et nende ventiilide reguleerimine n\u00f5uab, nagu k\u00f5ikide tasakaalustusventiilide puhul, t\u00e4pset esialgset h\u00fcdraulilist reguleerimist.<br \/>Nagu me hiljem n\u00e4eme, kui tasakaalustamine toimub vooluhulkade reguleerimise teel, on nende kindlaksm\u00e4\u00e4ramiseks \u2013 kuna olemasolevate rajatiste kohta puuduvad andmed \u2013 vaja projekteerimisb\u00fcroo abi.<\/p>\n<p class=\"text-justify push-top\">\u00a0<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>T\u00d6\u00d6STUSETEGIJATE ANAL\u00dc\u00dcS JA OSKUSTEADMISED<\/h2>\n<\/div>\n<p class=\"text-justify push-top\"><em>Kasutusel on kolm p\u00f5lvkonda tasakaalustusventiile.<\/em><\/p>\n<p><strong>1<sup>ajastu<\/sup> p\u00f5lvkond: staatilised ja mitte-mahulised tasakaalustuskraanid v\u00f5i -ventiilid.<\/strong><br \/>Nende kraanidega ei ole v\u00f5imalik m\u00f5\u00f5ta voolukiirust.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Mittevolumetrilised tasakaalustusventiilid\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec18.jpg\" alt=\"\" width=\"650\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\"><em>Joonis 4: Mittevolumetrilised tasakaalustusventiilid<\/em><\/p>\n<p class=\"text-justify push-top\">Neid saab reguleerida kahel viisil:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Jaotuste h\u00fcdrauliline simulatsioon<\/li>\n<li class=\"pad5\">Tasakaalustatavate antennide tagasivoolutemperatuuride \u00fchtlustamine<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">V\u00f5rgustiku h\u00fcdrauliline modelleerimine eeldab v\u00f5rgustiku \u00fcksikasjalikku kaardistamist (l\u00f5ikude pikkused, l\u00e4bim\u00f5\u00f5dud jne), paigaldatud ventiilide h\u00fcdraulilise k\u00e4itumise kindlaksm\u00e4\u00e4ramist ning igale harule reguleeritavate vooluhulkade arvutamist.<br \/>Olemasolevate rajatiste puhul on k\u00f5igi nende andmete kogumine keeruline ning sellest tulenevad ebakindlused piiravad v\u00f5imalusi hea tulemuse h\u00f5lpsaks saavutamiseks.<\/p>\n<p>Kui seadmed on varustatud selliste kraanidega, on parim lahendus toimida j\u00e4rgmiselt: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/methode-dequilibrage-equilog\/\" target=\"_blank\" rel=\"noopener noreferrer\">tasakaalustatavate harude tagasivooluvee temperatuuride \u00fchtlustamine. <\/a><br \/>Seda uut meetodit tutvustatakse edaspidi.<\/p>\n<p><strong>2<sup>\u00e8me<\/sup> p\u00f5lvkond: staatilised ja mahup\u00f5hised tasakaalustuskraanid v\u00f5i -ventiilid.<\/strong><br \/>Need kraanid v\u00f5imaldavad m\u00f5\u00f5ta voolukiirust voolus.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Mahtulised tasakaalustusventiilid\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec5.jpg\" alt=\"\" width=\"451\" height=\"230\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 5: Mahulised tasakaalustusventiilid <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> ja <a class=\"bleu\" href=\"http:\/\/www.comap.fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">Comap<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Neid saab reguleerida kolme meetodiga:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Jaotuste h\u00fcdrauliline simulatsioon<\/li>\n<li class=\"pad5\">Vooluhulga reguleerimine ja kontrollimine kohapealse m\u00f5\u00f5tmise abil<\/li>\n<li class=\"pad5\">Tasakaalustatavate harude tagasivooluvee temperatuuride \u00fchtlustamine<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Kui esimene lahendus j\u00e4etakse k\u00f5rvale, arvestades sellega seotud raskusi olemasolevate paigaldiste puhul, tuleb m\u00e4rkida, et vooluhulga reguleerimise teel t\u00f6\u00f6tamine n\u00f5uab samuti projekteerimisb\u00fcroo kaasamist, et m\u00e4\u00e4rata kindlaks iga tasakaalustatava antenni puhul reguleeritav vooluhulk.<br \/>Olemasolevate s\u00fcsteemide puhul on k\u00f5ige lihtsam lahendus ikkagi tagasivooluvee temperatuuri \u00fchtlustamine.<\/p>\n<p><strong>3<sup>\u00e8me<\/sup> p\u00f5lvkond: d\u00fcnaamilised tasakaalustuskraanid v\u00f5i -klapid<\/strong><br \/>Need on viimase p\u00f5lvkonna tasakaalustusventiilid, mis on m\u00f5eldud paigaldamiseks <strong>muutuva voolukiirusega vooluringid <\/strong>n\u00e4iteks need, mis on varustatud termostaatventiilidega.<\/p>\n<p>Tuleb eristada kahte liiki kraane:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Tasakaalustuskraanid v\u00f5i -ventiilid \u00ab <em>erinevusr\u00f5hu regulaatorid <\/em>\u00bb<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Erineva r\u00f5hu reguleerimisventiilid\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec7.jpg\" alt=\"\" width=\"650\" height=\"207\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 6: Erinevusr\u00f5hu reguleerimisventiilid <a class=\"bleu\" href=\"http:\/\/honeywell.com\/country\/fr\/Pages\/home.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">Honeywell<\/a> ja <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Termostaatventiilidega (Rth) varustatud jaotuss\u00fcsteemis suureneb haru toiter\u00f5hu vahe (DP), kui need \u00absulguvad\u00bb. See DP suurenemine takistab Rth-ventiilide sulgumist ja p\u00f5hjustab voolukiiruse suurenemist neis andurites, mille termostaatventiilid ei ole veel sulgunud.<br \/>Sellises olukorras tuvastab diferentsiaalr\u00f5hu reguleerimisventiil diferentsiaalr\u00f5hu t\u00f5usu ja \u00absulgeb\u00bb end, et see taastada.<\/p>\n<p>Teatavad mudelid, nagu n\u00e4iteks \u00fclaloleval fotol kujutatud mudelid, ei ole mahulised ja seet\u00f5ttu ei v\u00f5imalda need reguleeritud vooluhulga m\u00f5\u00f5tmist. Nende reguleerimine v\u00f5i reguleerimise kontrollimine peab toimuma tagasivoolu temperatuuri m\u00f5\u00f5tmise teel.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>\u00e8me<\/sup> d\u00fcnaamiliste tasakaalustusventiilide t\u00fc\u00fcp: automaatsed tasakaalustusventiilid<\/strong> <em>(mida nimetatakse ka isetasakaalustuvateks v\u00f5i toiter\u00f5hust s\u00f5ltumatuteks v\u00f5i PIBCV-deks v\u00f5i vooluregulaatoriteks)<\/em><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Nn \u00abautomaatsed\u00bb tasakaalustusventiilid\u00bb\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec8.jpg\" alt=\"\" width=\"250\" height=\"253\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 7: Nn \u00abautomaatsed\u00bb tasakaalustusventiilid\u00bb <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Need kraanid on loodud selleks, et v\u00f5imaldada <strong>\u00fche l\u00f5ppseadme seadistamine<\/strong> n\u00e4iteks CTA v\u00f5i ventilaator-konvektori k\u00fctteelement.<br \/>Need v\u00f5ivad olla mootoriga varustatud, mis v\u00f5imaldab seadme reguleerimist optimaalsete h\u00fcdrauliliste t\u00f6\u00f6tingimuste saavutamiseks.<\/p>\n<p>Neid kasutatakse m\u00f5nikord selliste antennide tasakaalustamiseks, mis koosnevad <strong>mitu v\u00e4ljundit, mis on varustatud kahekanaliliste reguleerimisklappidega<\/strong> nagu n\u00e4iteks termostaatventiilidega varustatud radiaatorid. Sellisel juhul asendavad automaatsed tasakaalustusventiilid diferentsiaalr\u00f5hu reguleerimisventiile, mida tavaliselt sellisel juhul kasutatakse.<\/p>\n<p>Sellist olukorda ei olnud algselt ette n\u00e4htud ja seda ei ole tootjate tehnilistes spetsifikatsioonides mainitud. T\u00f5epoolest, automaatse tasakaalustusventiili t\u00f6\u00f6 ei ole sel juhul p\u00e4ris optimaalne ning sarnaneb selles olukorras pigem staatilise tasakaalustusventiili t\u00f6\u00f6p\u00f5him\u00f5ttega.<\/p>\n<p>Selle toimimist saab uurida, lugedes j\u00e4rgmist artiklit: <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u00abAutomaatne tasakaalustamine \u2013 edu eeldused\u00bb<\/a><\/p>\n<p>Selle artikli l\u00f5pus olevates kommentaarides on esitatud kahe suure tootja seisukoht.<br \/>Seega t\u00e4psustab IMI \u2013 Hydronic j\u00e4rgmist:<br \/><em>\u00abAutomaatventiilide paigaldamise kohta (PIBCV, k\u00e4esoleval juhul vooluregulaator) paigaldamisel muutuva vooluhulgaga torustikesse (n\u00e4iteks termostaatventiilidega varustatud eluruumidesse) n\u00f5uavad meie seisukohad h\u00fcdraulika valdkonna ekspertide ja t\u00f6\u00f6stusekspertidena, et meie seisukohad oleksid tehniliselt veatud. Kuigi tuleb tunnistada, et PIBCV-de paigaldamine eluruumide sissep\u00e4\u00e4su juurde on \u00fcha levinum, ei saa me eetilistel kaalutlustel seda tava soodustada.\u00bb<\/em><\/p>\n<p>Oventrop, kes on selles k\u00fcsimuses pragmaatilisem, m\u00e4rgib <em>et kuigi h\u00fcdraulikas tuleb teha m\u00f5ningaid tehnilisi j\u00e4releandmisi, on automaatkraanidega saavutatav \u00fcldine reguleerimine ikkagi palju parem kui staatiliste kraanide ja r\u00f5huregulaatoritega saavutatav, kuna neid viimaseid reguleeritakse enamasti v\u00e4he v\u00f5i \u00fcldse mitte.<\/em><\/p>\n<p>T\u00f5epoolest, diferentsiaalr\u00f5hu regulaatorite seadistamine j\u00e4tab sageli soovida, eriti mudelite puhul, mis ei ole volumetrilised. Kui ei kasutata tagasivoolu temperatuuri m\u00f5\u00f5tmist, saab neid seadistada ainult h\u00fcpoteetilise r\u00f5hukao arvutuse alusel. Kui soovitakse tasakaalustamist l\u00e4bi viia voolukiiruse m\u00f5\u00f5tmise abil, on h\u00e4davajalik valida mahup\u00f5hised mudelid, ning mitmed tootjad pakuvad kohandatavaid mahup\u00f5hiseid ventiile.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Sobiv voolukraan koos Oventropi diferentsiaalr\u00f5hu reguleeriva kraaniga\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec17.jpg\" alt=\"\" width=\"513\" height=\"150\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 6 bis: Mahuklapp, millele on paigaldatud diferentsiaalr\u00f5hu regulaator <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Kokkuv\u00f5tteks tuleb eelk\u00f5ige m\u00e4rkida, et ei tohi segi ajada \u00abkraanide paigaldamist\u00bb ja \u00abkraanide reguleerimist\u00bb, s\u00f5ltumata paigaldatud mudelite p\u00f5lvkonnast.<\/p>\n<p>Nagu eelmiste p\u00f5lvkondade puhul, tuleb ka d\u00fcnaamilisi tasakaalustusventiile hoolikalt esialgselt reguleerida. Seda reguleerimist saab teostada simulatsiooni ja\/v\u00f5i voolukiiruse m\u00f5\u00f5tmiste ja\/v\u00f5i tagasivoolu temperatuuri m\u00f5\u00f5tmiste abil. Seda teemat k\u00e4sitletakse j\u00e4rgmises l\u00f5igus.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>TASAKAALUSTAMISMEETODID<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Olemasolevates \u00fchisk\u00fcttes\u00fcsteemides, <strong>kolm metoodikat <\/strong>tasakaalustusventiilide esialgseks reguleerimiseks kasutatakse t\u00e4nap\u00e4eval.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>1<sup>ajastu<\/sup> meetod: v\u00f5rkude h\u00fcdraulilise k\u00e4itumise simulatsioon<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"V\u00f5rkude h\u00fcdraulilise k\u00e4itumise simulatsioon\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec9.jpg\" alt=\"\" width=\"492\" height=\"446\" \/><\/p>\n<p class=\"text-justify push-top\">Olemasolevates s\u00fcsteemides on teoreetiliselt v\u00f5imalik teha vajalikud m\u00f5\u00f5tmised vooluhulkade ja r\u00f5hukadude hindamiseks, et arvutuste abil leida tasakaalustusventiilide eelseadistus. Tegemist on aga keerulise \u00abotsingum\u00e4nguga\u00bb, v\u00e4lja arvatud juhul, kui on v\u00f5imalik kasutada jaotusplaane, mis on harva k\u00e4ttesaadavad.<\/p>\n<p>Seda v\u00f5imalust on eriti p\u00f5hjalikult arendanud <a class=\"bleu\" href=\"http:\/\/edipa.fr\/LibrairieTechnique\/Auteur?auteur=FRIDMANN%20Pierre&amp;page=1\" target=\"_blank\" rel=\"noopener noreferrer\">H\u00e4rra Pierre Fridmann<\/a> eeldab v\u00f5imalust kontrollida hiljem k\u00f5igi tehtud eelseadistuste tulemusi, kas voolukiiruste m\u00f5\u00f5tmise v\u00f5i tagasivoolava vee temperatuuri m\u00f5\u00f5tmise teel.<\/p>\n<p>See meetod on m\u00f5eldud pigem uutele v\u00f5i hiljuti paigaldatud s\u00fcsteemidele, millel ei esine veel etten\u00e4gematuid ummistusi ja mille kohta on olemas k\u00f5ik vajalikud arvutusandmed.<br \/>Seda saab eelk\u00f5ige kasutada r\u00f5huerinevuste kindlaksm\u00e4\u00e4ramiseks, mida tuleb reguleerida \u00aberir\u00f5hu regulaatoritel\u00bb, millel on reguleerimisskaala r\u00f5hu\u00fchikutes.<br \/>Simulatsiooni tulemuse abil on v\u00f5imalik torustiku seadistada eelnevalt, enne kui kohapeal kontrollitakse ja reguleeritakse tegelikult saavutatud veevoolu v\u00f5i tagasivoolu temperatuuri.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>\u00e8me<\/sup> meetod: Transporditavate vooluhulkade arvutamine, reguleerimine ja kontrollimine<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Meetod seisneb vooluhulkade arvutamises ja reguleerimises. Selleks on muidugi vaja nn \u00abmahulisi\u00bb \u2013 staatilisi v\u00f5i d\u00fcnaamilisi \u2013 ventiile, mis v\u00f5imaldavad vooluhulga m\u00f5\u00f5tmist.<br \/>Seega ei kehti see j\u00e4rgmiste suhtes: <strong>mittevolumetrilised kraanid<\/strong> nagu n\u00e4iteks radiaatorite v\u00e4ljalaskeavades paigaldatud lihtsad reguleerimisventiilid, aga ka torukolonnide jalamil ja eelk\u00f5ige p\u00f5randak\u00fctte kontuuride tagasivoolutorudes.<\/p>\n<p>Tuleb ka meeles pidada, et m\u00f5ned diferentsiaalr\u00f5hu regulaatorid ei ole mahulised. Nende reguleerimine v\u00f5i reguleerimise kontrollimine peab toimuma ainult tagasivoolu temperatuuri m\u00f5\u00f5tmise teel.<\/p>\n<p>Olemasolevate s\u00fcsteemide puhul peab projekteerimisb\u00fcroo reguleeritavate vooluhulkade kindlaksm\u00e4\u00e4ramiseks tegema vajalikud m\u00f5\u00f5tmised, et hinnata iga reguleeritava k\u00fctteseadme juures tekkivaid soojuskadusid.<br \/>Selleks peab ta arvutama v\u00e4lja soojuskadud nii standardruumides kui ka eriruumi (terrassi all, katuseharja \u00e4\u00e4res jne). Seej\u00e4rel \u2013 mis on sageli v\u00e4ga keeruline \u2013 peab ta need \u00f5igesti jaotama iga reguleeritava antenni vahel.<\/p>\n<p>Vooluhulga reguleerimiseks on vaja kasutada m\u00f5\u00f5teseadet ning juhul, kui kraanid ei ole d\u00fcnaamilised, tuleb rakendada spetsiaalset meetodit.<br \/>Seda meetodit saab hankida aadressilt <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-debit.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Eformation Xpair<\/a> v\u00f5i aadressil <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulaator.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Voolukiiruse kontroll\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec10.jpg\" alt=\"\" width=\"551\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 9: Voolukiiruse kontroll Allikas <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> ja m\u00f5\u00f5tekohver <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Kui reguleeritavad kraanid on<strong> d\u00fcnaamiline <\/strong>Voolukiiruste reguleerimine on lihtsam, ilma et oleks vaja kasutada mingit erilist meetodit; piisab vaid sellest, et veenduda, et k\u00f5ige ebasoodsamas asendis olevale kraanile on tagatud piisav toiter\u00f5hu vahe.<\/p>\n<p>Teatavatel vooluhulga j\u00e4rgi kalibreeritud d\u00fcnaamilistel kraanidel on eelseadistamine v\u00f5imalik ilma m\u00f5\u00f5tmiseta, kuid see ei vabasta kohustusest m\u00f5\u00f5ta l\u00f5plikult saadud vooluhulki p\u00e4rast k\u00f5igi kraanide eelseadistamist.<br \/>Mudelite puhul, millel puudub voolukiiruse skaala, eelk\u00f5ige diferentsiaalr\u00f5hu regulaatorite puhul, ei ole voolukiiruse reguleerimine v\u00f5imalik ilma selle tegeliku m\u00f5\u00f5tmiseta (kui tegemist on muide mahuliste reguleerijatega).<\/p>\n<p>Kui k\u00f5ik d\u00fcnaamilised kraanid on reguleeritud v\u00f5i eelseadistatud \u2013 juhul, kui tegemist on mahup\u00f5histe kraanidega \u2013, l\u00f5petatakse p\u00f5hjalik tasakaalustamine k\u00f5igi voolavate vooluhulkade m\u00f5\u00f5tmisega, et veenduda, et harude vahelised h\u00fcdraulilised vastasm\u00f5jud on n\u00f5uetekohaselt arvesse v\u00f5etud.<br \/>Tuleb ju meeles pidada, et piisab vaid m\u00f5nest ebasoodsas olukorras olevast antennist, et kogu \u00fclej\u00e4\u00e4nud jaotusv\u00f5rk \u00fclekuumeneks, ning ringide h\u00fcdrauliline k\u00e4itumine, eriti olemasolevate puhul, pakub sageli palju \u00fcllatusi.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>3<sup>\u00e8me<\/sup> meetod: Veetagastustemperatuuride m\u00f5\u00f5tmine ja \u00fchtlustamine k\u00fctteperioodil<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">See uuem lahendus, mida nimetatakse \u00abEQUILOG-meetodiks\u00bb, seisneb selles, et kui k\u00fcttes\u00fcsteem t\u00f6\u00f6tab ja v\u00e4ljundtemperatuur on stabiliseerunud, siis <strong>vee tagasivoolu temperatuuri m\u00f5\u00f5tmine <\/strong>antenne tuleb tasakaalustada ja \u00fchtlustada nii, et k\u00f5ik reguleeritavad antennid oleksid \u00fcksteisega \u00absama kuumad\u00bb.<\/p>\n<p>Kuigi see meetod tundub \u00ablihtsakoeline\u00bb, on see olnud ja on endiselt konkurentide poolt loomuliku kriitika objektiks. Selle teema kohta v\u00f5ib lugeda <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-hydraulique-methode-simple.htm\" target=\"_blank\" rel=\"noopener\">\u00abH\u00fcdrauliline tasakaalustamine: uuendused lihtsa meetodi jaoks\u00bb. <\/a>Kuid v\u00f5ib m\u00e4rkida, et mitmesajas asukohas on siiani sellisel viisil kasumlikult k\u00e4ideldud \u00fcle 80 000 eluasemeekvivalendi.<\/p>\n<p>P\u00e4rast tasakaalustamist on antennide tagasivoolu temperatuurid ning edasi- ja tagasivoolu temperatuuride erinevused v\u00f5rreldavad <em>(*)<\/em>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"K\u00fcttes\u00fcsteemi veetemperatuuride \u00fchtlustamine\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec12.gif\" alt=\"\" width=\"573\" height=\"229\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 11: K\u00fcttes\u00fcsteemi veetemperatuuride \u00fchtlustamine(*)<\/em><\/p>\n<p class=\"text-justify push-top\"><em>(*) Kui h\u00fcdrauliline jaotus seda v\u00f5imaldab, on muidugi v\u00f5imalik seadistada igale harule erinevad veetemperatuurid, et v\u00f5tta arvesse kohalikke soojustamismeetmeid. <\/em><br \/><em>Siiski on t\u00e4heldatud, et hoonetes, kus on l\u00e4bi viidud \u00fchtlane soojusrenoveerimine (k\u00f5igi akende ja uste vahetamine, k\u00f5igi v\u00e4lisseinte soojustamine), tasakaalustamine <u>esialgne v\u00f5i hilisem<\/u> Hea tulemuse saavutamiseks piisab veetemperatuuri \u00fchtlustamisest. <\/em><br \/><em>K\u00fcttev\u00f5imsust saab seej\u00e4rel reguleerida lihtsalt katlaruumist v\u00e4ljuvate vee temperatuuri reguleerimise teel (k\u00fcttek\u00f5vera reguleerimine).<\/em><\/p>\n<p>K\u00f5ikidele kraanit\u00fc\u00fcpidele kohaldatavat protsessi on \u00f5nnestunud optimeerida t\u00e4nu infrapunatermomeetria valdkonnas tehtud edusammudele ja GMTI94 \u2013 GEFEn poolt l\u00e4bi viidud uuringutele.<br \/>Selle p\u00f5him\u00f5tet saab uurida <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-temp.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Eformation Xpair<\/a> v\u00f5i aadressil <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulaator<\/a>.<\/p>\n<p>Selle metoodika peamine eelis on see, et tavap\u00e4raselt m\u00f5\u00f5detud v\u00f5rkude puhul ei ole vaja teha kadude arvutusi ega v\u00f5rgu m\u00f5\u00f5tmisi. Seet\u00f5ttu sobib see eriti h\u00e4sti olemasolevatele v\u00f5rkudele, mille kohta on harva andmeid olemas.<\/p>\n<p>Seda menetlust, mida 2000. aastatel katseliselt kasutusele v\u00f5eti, on patenteeritud Prantsusmaal ja hiljuti ka 15 Euroopa riigis.<br \/>\u00abEQUILOG\u00bb-meetodit rakendavad eelk\u00f5ige <em>\u00ab <\/em><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><em>ettev\u00f5te MAPSEC <\/em><\/strong><\/a><em>\u00bb(*) <\/em>mitmete k\u00e4itamis- ja paigaldusettev\u00f5tete (Dalkia, Cofely-Soccram, Idex jne) nimel.<br \/><em>(*) MAPSEC, 80 rue de Paris, 93100 Montreuil, tel: 01 48 59 06 05 \u2013 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr<\/a><\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Tsirkulatsioonipump\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec11.jpg\" alt=\"\" width=\"250\" height=\"187\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis nr 10: Veetemperatuuri kontroll Allikas <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/\" target=\"_blank\" rel=\"noopener noreferrer\">Mapsec<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">L\u00f5petuseks tuleb m\u00e4rkida, et <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">artikkel, mis k\u00e4sitleb d\u00fcnaamilisi tasakaalustusventiile<\/a> Nagu eelmises l\u00f5igus mainitud, m\u00e4rgib Oventropi esindav insener seda toimiku l\u00f5pus olevates m\u00e4rkustes.<br \/><em>\u00abOlemasolevate s\u00fcsteemide puhul on tagasivoolu temperatuuri \u00fchtlustamine minu arvates samuti parim meetod, kui valitud temperatuuri langus on \u00f5ige.\u201c.<br \/>Sellest hoolimata on see meetod aegan\u00f5udev ja elamute paigaldajad ei v\u00f5ta seda h\u00e4sti vastu, kui seda tuleb teha k\u00e4sitsi.<br \/>\u00bbOn olemas kraanid, mis teevad seda automaatselt, kuid hind on teine.\u201c<\/em><\/p>\n<p>T\u00f5epoolest n\u00f5udis tasakaalustamine tagasivoolu temperatuuri \u00fchtlustamise teel varem pikki ooteaegu, kuni temperatuur stabiliseerus, kuid t\u00e4nu viimastele edusammudele on see n\u00fc\u00fcd v\u00f5imalik v\u00e4ltida ja protseduuride kestus on muutunud v\u00e4ga konkurentsiv\u00f5imeliseks.<\/p>\n<p>Lisaks v\u00f5iks t\u00f5epoolest kaaluda tasakaalu automaatset saavutamist ja pikaajalist s\u00e4ilitamist tagasivoolu temperatuuride \u00fchtlustamise teel. Kuid praeguse tehnoloogia taseme juures n\u00f5uaks see mootoriga varustatud automaatsete tasakaalustusventiilide paigaldamist ja elektritoitega varustamist, mis on \u00fchendatud automaatikaga v\u00f5i hooneautomaatikas\u00fcsteemiga.<br \/>Majanduslikust seisukohast on see praegu veel raske ette kujutada, v\u00e4hemalt olemasolevate rajatiste puhul.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>PAIGALDAJATE ANAL\u00dc\u00dcS JA OSKUSED<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Eelk\u00f5ige tuleb selgelt eristada vee eemaldamist (vajaduse korral) ja tasakaalustuskraanide paigaldamist nende esialgsest reguleerimisest.<\/p>\n<p>T\u00f5epoolest, olenemata kraani t\u00fc\u00fcbist on paigaldus- v\u00f5i puhastusettev\u00f5ttel kiusatus lisada oma pakkumisse kasutuselev\u00f5tu teenus, ilma et neil alati oleks v\u00f5imalik k\u00f5iki selle parameetreid kindlaks m\u00e4\u00e4rata.<\/p>\n<p>Loomulikult v\u00f5ib ette kujutada, et \u00fcks ja sama ettev\u00f5te suudab kogu tasakaalustamisprotsessi l\u00e4bi viia, kuid sel juhul peab tal olema meeskondi, kellel on v\u00e4ga erinevad praktilised ja teoreetilised oskused.<\/p>\n<p>Seega tuleb \u00fcldiselt olla \u00e4\u00e4rmiselt ettevaatlik tasakaalustamistoiminguks sobiva ettev\u00f5tte valimisel. Tegemist on keerulise tehnilise erialaga ning eba\u00f5nnestumisi esineb palju, kuna tehtud t\u00f6\u00f6 kvaliteedi kontrollimine on keeruline.<\/p>\n<p>Isegi kui see tooks kaasa lisakulusid, ei k\u00f5hkle me seet\u00f5ttu tegevusi eraldamast nii, et uuringu- ja\/v\u00f5i arendusetapid viiksid l\u00e4bi asjaomase valdkonna spetsialistid.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radiaator\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec13.jpg\" alt=\"\" width=\"450\" height=\"173\" \/><\/p>\n<p class=\"text-justify push-top\">Hea valikuv\u00f5imalus on k\u00fcsida konsultatsiooni ajal, millist meetodit kasutatakse, ning lasta t\u00e4pselt selgitada, millised andmed p\u00e4rast protseduuri esitatakse.<br \/>Mis tahes ebam\u00e4\u00e4rasus v\u00f5i k\u00f5hklus vastustes, mis puudutavad \u00fcht v\u00f5i teist neist kahest punktist, on kahtlemata m\u00e4rk sellest, et esitus ei ole h\u00e4sti l\u00e4bi m\u00f5eldud.<\/p>\n<p>Kui ettev\u00f5te t\u00f6\u00f6tab voolukiiruse m\u00f5\u00f5tmise v\u00f5i h\u00fcdraulilise simulatsiooni alusel, v\u00f5ib seega n\u00f5uda, et pakkumine sisaldaks l\u00f5plikku hinnaalandust:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Kao \u00fcksikasjalik arvutamine <strong>iga t\u00f6\u00f6deldava kraani juures<\/strong> ja mille tulemusel on kindlaks m\u00e4\u00e4ratud tasumisele kuuluvad summad. Nii saab veenduda, et k\u00f5nealused summad ei ole tekkinud ligikaudsete hinnangute p\u00f5hjal.<\/li>\n<li class=\"pad5\">V\u00f5re <strong>sertifitseeritud<\/strong> m\u00f5\u00f5detud voolukiirused <u>p\u00e4rast k\u00f5igi kraanide reguleerimist<\/u> (ja mitte piirduda vaid teoreetiliselt prognoositud vooluhulkade tabeliga). Nii saab veenduda, et reguleeritavate antennide vahelised h\u00fcdraulilised vastasm\u00f5jud on t\u00f5epoolest arvesse v\u00f5etud, ning vajaduse korral seda kontrollida.<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Kui ettev\u00f5te t\u00f6\u00f6tab tagasivoolu temperatuuri m\u00f5\u00f5tmise p\u00f5him\u00f5ttel, v\u00f5ib n\u00f5uda, et pakkumine sisaldaks j\u00e4rgmist:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">M\u00f5ned asjakohased viited v\u00f5i veelgi parem \u2013 v\u00e4hemalt \u00fche varem l\u00e4biviidud operatsiooni \u00fcksikasjaliku aruande esitamine. Nii saab veenduda kandidaadi kogemuses, sest kuigi meetodi p\u00f5him\u00f5te on vana, on seda alles hiljuti \u00f5pitud t\u00f5eliselt valdama.<\/li>\n<li class=\"pad5\">Graafiku taasesitamine <strong>sertifitseeritud, terviklik ja \u00fcksikasjalik<\/strong> m\u00f5\u00f5detud tagasivoolu temperatuurid,<strong> enne ja p\u00e4rast tasakaalustamist<\/strong>, m\u00e4rkides \u00e4ra stabiliseerunud v\u00e4ljundtemperatuurid, mille juures need m\u00f5\u00f5tmised tehti. Nii on v\u00f5imalik veenduda tehtud t\u00f6\u00f6 kvaliteedis.<\/li>\n<\/ul>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>TASUVUS JA ENERGIAS\u00c4\u00c4ST<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Tasakaalustamisprotseduuri tulemusel saavutatavat energias\u00e4\u00e4stu ei ole lihtne ennustada.<br \/>T\u00f5epoolest, kuigi t\u00e4iuslikult l\u00e4biviidud tasakaalustamise korral on seda v\u00f5imalik hinnata algsete ruumitemperatuuride kaardistuse p\u00f5hjal, on seda tegelikult v\u00e4ga raske t\u00f5lgendada.<br \/>Igal juhul, kui otsustatakse kasutada seda hindamismeetodit, tuleb tugineda andmetele, mis on kogutud v\u00e4ga k\u00fclmal perioodil ja ilma igasuguse tasuta energiatootmiseta (p\u00e4ikesepaiste, elektriseadmed jne), mitte hetkem\u00f5\u00f5tmistele.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"N\u00e4ide \u00f5hutemperatuuri registreerimisest, mida m\u00f5jutavad tasuta sissetoimetused\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec15.jpg\" alt=\"\" width=\"400\" height=\"235\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Joonis 15: N\u00e4ide \u00f5hutemperatuuri m\u00f5\u00f5tmistulemustest, mida m\u00f5jutavad tasuta soojusallikad<\/em><\/p>\n<p class=\"text-justify push-top\">Veelgi keerulisem on aga arvestada nende tasakaalustusventiilide paigaldamisega, mida on tegelikult v\u00f5imalik reguleerida. T\u00f5epoolest, olemasolevates k\u00fcttes\u00fcsteemides toimub tasakaalustamine \u00fcldjuhul ainult neil ventiilidel, millele on juurdep\u00e4\u00e4s 2<sup>\u00e8me<\/sup> tase (vt 2<sup>\u00e8me<\/sup> \u00a7). Seet\u00f5ttu s\u00f5ltub selle 2. rakendamise edukus<sup>\u00e8me<\/sup> Tase on oluline parameeter oodatava energias\u00e4\u00e4stu hindamisel.<\/p>\n<p>Selles osas kasutab ettev\u00f5te MAPSEC nn metoodikat <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/ecomapsec\/\" target=\"_blank\" rel=\"noopener noreferrer\">REQUILOG<\/a> mis v\u00f5imaldab tal reguleeritavate kraanide k\u00f5rgusel m\u00f5\u00f5detud tagasivooluvee temperatuuride kaardistuse p\u00f5hjal hinnata, kui suur on tasakaalustamatuse ulatus, mida on tegelikult v\u00f5imalik k\u00f5rvaldada.<br \/>Seet\u00f5ttu eelneb talle usaldatud tasakaalustamisoperatsioonidele v\u00f5imaluse korral diagnostiline protseduur, mis h\u00f5lmab ka seda hindamist, mis v\u00f5imaldab otsustajal paremini hinnata, kas operatsiooni l\u00e4biviimine on otstarbekas v\u00f5i mitte.<\/p>\n<p>L\u00f5petuseks tuleb m\u00e4rkida, et tasakaalustamisest tulenev energias\u00e4\u00e4st eeldab hiljem selle reguleerimise eest vastutava tehniku kaasamist.<br \/>T\u00f5epoolest, kui tasakaalustamine t\u00e4hendaks l\u00f5ppkokkuv\u00f5ttes seda, et algselt k\u00f5ige halvamini k\u00fctetud ruumid viidaks samale tasemele k\u00f5ige paremini k\u00fctetud ruumidega, ei oleks tulemuseks energias\u00e4\u00e4st\u2026<\/p>\n<p>\u00dcldiselt tundub, et keskmine energias\u00e4\u00e4st % p\u00e4rast k\u00fcttes\u00fcsteemi jaotuss\u00fcsteemi tasakaalustamist on umbes 7%, kusjuures investeering tasub end \u00e4ra umbes 2\u20133 aastaga, kui s\u00fcsteemis ei ole vaja vahetada kraane v\u00f5i on vaja vahetada vaid v\u00e4heseid.<\/p>\n<p>Kuni 2014. aasta detsembrini oli neid meetmeid v\u00f5imalik kaasata energias\u00e4\u00e4stu sertifikaatide s\u00fcsteemi, kus energias\u00e4\u00e4stu kindlaksm\u00e4\u00e4ratud protsendim\u00e4\u00e4r oli 10%.<br \/>Vastavaid BAR- ja BAT SE 04-vormid on praegu muutmisel. Need peaksid ilmuma uute nimetuste all j\u00e4rgmises Euroopa ettev\u00f5tlusn\u00f5ukogudele p\u00fchendatud ministri m\u00e4\u00e4ruses.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"ECO-nupp\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec14.jpg\" alt=\"\" width=\"250\" height=\"180\" \/><\/p>\n<p class=\"text-justify push-top\">L\u00f5petuseks v\u00f5ib kindlalt \u00f6elda, et tasakaalustamistoimingud on \u00fcldiselt t\u00e4iesti tasuvad, kui neid teostatakse rangelt.<\/p>\n<p>Selle parimaks t\u00f5endiks on Dalkia ettev\u00f5tte tasakaalustusteenistuse t\u00f6\u00f6 \u00cele-de-France\u2019i piirkonnas(*), mis loodi umbes k\u00fcmme aastat tagasi EQUILOG-meetodi rakendamiseks ja mida praegu juhib Christophe Tillay.<br \/>Xpairis saab lugeda \u00fche tema saavutuse \u00fclevaadet artiklis <a class=\"bleu\" href=\"http:\/\/conseils.xpair.com\/actualite_experts\/exemple-operation-equilibrage-egalisation-temperatures-retour.htm\" target=\"_blank\" rel=\"noopener noreferrer\">\u00abTasakaalustamine tagasivoolu temperatuuri \u00fchtlustamise teel\u00bb.<\/a><\/p>\n<p><em>(*) Dalkia Ile-de-France, tasakaalustamise osakond, 28 Boulevard de Pesaro, 92 751 NANTERRE CEDEX Tel: 01 55 67 68 97 <\/em><\/p>\n<p>Selle teenistuse poolt l\u00e4bi viidud sadad tasakaalustamistoimingud on toimunud ainult ettev\u00f5tte poolt hallatavates kinnisvarakompleksides MF-lepingute (kindlasummaline leping) v\u00f5i MT-lepingute (temperatuurileping) raames. Selliste lepingute puhul, mis ei ole veel piisavalt levinud, maksab klient k\u00e4itajale igal aastal kindlasummalist (v\u00f5i DJU-ga korrigeeritud) summat, et tagada optimaalne k\u00fcttevarustus.<\/p>\n<p>K\u00fctuse hankimine on sel juhul t\u00e4ielikult k\u00e4itajale koormaks. Seega on tema esmane huvi v\u00e4hendada k\u00fctusekulu nii palju, kui see ei kahjusta kliendi soojustaset, kuna kogu saavutatud energias\u00e4\u00e4st j\u00e4\u00e4b talle endale.<\/p>\n<p>Selline tehing motiveerib teenusepakkujat loomulikult rajatist v\u00f5imalikult h\u00e4sti haldama ja sinna oma parimad meeskonnad suunama. Keskkonnakaitse seisukohast on olukord seega optimaalne.<br \/>Omakorda on kliendil ilma erilisete lisakuludeta tagatud p\u00fcsiv ja h\u00e4sti reguleeritud k\u00fcte ning kindlus, et \u00fcldjuhul 8-aastaste lepingute l\u00f5ppedes saab ta tagasi v\u00f5imalikult h\u00e4sti hooldatud s\u00fcsteemi.<\/p>\n<p>Dalkia IdF tasakaalustusteenistuse poolt teostatud tasakaalustust\u00f6\u00f6d rahastati seega omavahenditest ning need tasusid end m\u00f5ne aastaga \u00e4ra t\u00e4nu saavutatud energias\u00e4\u00e4stule.<br \/>Selle teenuse s\u00e4ilitamine ja arendamine 10 aasta jooksul on vaieldamatu t\u00f5end selliste tegevuste heast tasuvusest.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Tasakaalustamise graafik\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec16.jpg\" alt=\"\" width=\"400\" height=\"250\" \/><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\" style=\"text-align: left;\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>KOKKUV\u00d5TE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\" style=\"text-align: left;\">Meie olemasolevate \u00fchisk\u00fcttes\u00fcsteemide energiatarbimise v\u00e4hendamine p\u00f5hineb soojustamisel, p\u00f5lemisprotsessi \u00f5igel reguleerimisel, juhtimiss\u00fcsteemidel ja tasakaalustamisel.<\/p>\n<p style=\"text-align: left;\">Hoolimata selle olulisest m\u00f5just kondensatsioonikatelde (ja koostootmisjaamade) reguleerimisele ja kasutegurile, oli viimane komponent seni n\u00f5rk l\u00fcli.<\/p>\n<p style=\"text-align: left;\">P\u00e4rast v\u00e4ga pikka pausi pole see probleem kunagi varem olnud nii aktuaalne.<\/p>\n<p style=\"text-align: left;\">Hiljutised edusammud torustike ja seadistamise valdkonnas peaksid v\u00f5imaldama paremini \u00e4ra kasutada \u00fcht olulisemat veel k\u00e4ttesaadavat energias\u00e4\u00e4stuallikat.<\/p>\n<\/div>\n<h4 class=\"text-primary push-top\" style=\"text-align: left;\"><strong>ALLIKAD JA LINGID<\/strong><\/h4>\n<ul class=\"push-top\">\n<li class=\"pad10\" style=\"text-align: left;\">SELGITUS: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/tapsustus\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mise-au-point<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">K\u00dcTTE-, VENTILATSIOONI- JA KLIMASEADMETE KASUTUSSEV\u00d5TT: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/commissioning\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/commissioning<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">KOHAPEALNE AUDIT: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/audit\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/audit<\/a><\/li>\n<li style=\"text-align: left;\">HERMETSUSKATSE \u00d5hukanalis\u00fcsteemid:\u00a0<a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mesure-de-letancheite-a-lair-des-reseaux-aeraulique<\/a><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/et\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">s<\/a><\/li>\n<li style=\"text-align: left;\">SIMULAATOR Tasakaalustamise \u00f5ppimine: <a href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564\" target=\"_blank\" rel=\"noopener\">www.edipa.fr\/LibrairieTechnique\/Details\/564<\/a><\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Par Patrick DELPECH &#8211; pour la soci\u00e9t\u00e9 MAPSEC &#8211; Mars 2020 Pour les responsables techniques et d\u00e9cideurs (maitres d\u2019ouvrage, syndic, etc.), les nouveaut\u00e9s du secteur, les<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16263","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/posts\/16263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/comments?post=16263"}],"version-history":[{"count":4,"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/posts\/16263\/revisions"}],"predecessor-version":[{"id":17284,"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/posts\/16263\/revisions\/17284"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/media?parent=16263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/categories?post=16263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/et\/wp-json\/wp\/v2\/tags?post=16263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}