{"id":16263,"date":"2015-09-01T17:36:27","date_gmt":"2015-09-01T16:36:27","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16263"},"modified":"2026-06-29T16:46:06","modified_gmt":"2026-06-29T14:46:06","slug":"totul-despre-echilibrarea-hidraulica-statica-automata","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/ro\/2015\/09\/01\/tout-sur-lequilibrage-hydraulique-statiqueautomatique\/","title":{"rendered":"Totul despre echilibrarea hidraulic\u0103 static\u0103 \u0219i automat\u0103"},"content":{"rendered":"<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/mapsec.fr\/ro\/contact\/\" style=\"border-radius:2px\">a solicita o ofert\u0103 de pre\u021b <\/a><\/div>\n<\/div>\n\n\n<p class=\"text-right small\" style=\"text-align: right;\">De Patrick DELPECH \u2013 pentru compania MAPSEC \u2013 martie 2020<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><em>Pentru responsabilii tehnici \u0219i factorii de decizie (proprietari, administratori de imobile etc.), nout\u0103\u021bile din sector, capcanele de evitat \u0219i condi\u021biile necesare pentru realizarea corespunz\u0103toare a echilibr\u0103rii hidraulice \u0219i termice.<\/em><\/p>\n<p>Aceast\u0103 pagin\u0103 prezint\u0103 principiile generale ale echilibr\u0103rii hidraulice statice \u0219i automate.<\/p>\n<p>Pentru a afla mai multe despre metoda MAPSEC aplicat\u0103 re\u021belelor de \u00eenc\u0103lzire centralizat\u0103, care include diagnosticarea, m\u0103sur\u0103torile, reglajele, validarea \u0219i metoda EQUILOG, consulta\u021bi pagina noastr\u0103 principal\u0103 dedicat\u0103\u2019<a href=\"https:\/\/mapsec.fr\/ro\/2016\/01\/13\/echilibrare-hidraulica-a-sistemului-de-incalzire-diagnosticare-gratuita\/\">echilibrarea hidraulic\u0103 a sistemului de \u00eenc\u0103lzire centralizat\u0103<\/a>.<\/p>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>PROBLEMATICA<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">\u00cen cadrul aceluia\u0219i circuit de \u00eenc\u0103lzire, prezen\u021ba simultan\u0103 a unor \u00eenc\u0103peri prea calde \u0219i a unor \u00eenc\u0103peri insuficient \u00eenc\u0103lzite este un semn al unei probleme foarte frecvente de dezechilibru.<br \/>Indiferent de cauza real\u0103 \u2013 reglaj hidraulic incorect, erori de dimensionare, izola\u021bii inegale etc. \u2013, problema poate fi remediat\u0103 prin reglarea a\u0219a-numitelor robinete de echilibrare, cu condi\u021bia ca acestea s\u0103 fie distribuite corespunz\u0103tor \u0219i s\u0103 fie suficient de accesibile.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"T-piece de reglare \u0219i robinet volumetric\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec1.jpg\" alt=\"\" width=\"529\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 1: Racord \u00een T de reglare \u0219i robinet volumetric <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Reglajul care trebuie efectuat const\u0103 \u00een limitarea debitelor robinetelor de la ramurile favorizate, astfel \u00eenc\u00e2t, pe m\u0103sur\u0103 ce debitul acestora scade, cel al ramurilor defavorizate s\u0103 creasc\u0103.<\/p>\n<p>Principiul de reglare este, a\u0219adar, u\u0219or de \u00een\u021beles, dar punerea sa \u00een practic\u0103 este mult mai delicat\u0103. Prezentul dosar prezint\u0103 condi\u021biile \u00een care o opera\u021biune de echilibrare hidraulic\u0103 se va desf\u0103\u0219ura corect, \u00een special \u00een cazul instala\u021biilor existente.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANALIZA \u0218I EXPERIEN\u021aA BIROURILOR DE PROIECTARE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">\u00cen general, o re\u021bea de distribu\u021bie a apei pentru \u00eenc\u0103lzire <strong>existent\u0103<\/strong> poate fi echilibrat\u0103 cu u\u0219urin\u021b\u0103 numai dac\u0103 s-au prev\u0103zut robinete de echilibrare <u>accesibile<\/u>, \u00een afara spa\u021biilor ocupate.<br \/>Dac\u0103 instala\u021bia nu este prea veche, acest aspect a fost, \u00een mod normal, prev\u0103zut de birourile de proiectare \u00eenc\u0103 din faza de proiectare a instala\u021biei, prin montarea unor robinete a\u0219a-numite de 2<sup>ema<\/sup> la nivelul de echilibrare, situate \u00een subsoluri, \u00een spa\u021biile sanitare sau chiar \u00een casa sc\u0103rilor \u0219i, \u00een orice caz, \u00een afara spa\u021biilor ocupate.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinete de echilibrare de nivel 2 \" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec2.jpg\" alt=\"\" width=\"650\" height=\"357\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura 2: Robinete de 2<sup>ema<\/sup> nivelul de echilibrare<\/em><\/p>\n<p class=\"text-justify push-top\">Circuitele care dispun doar de robinete de echilibrare montate pe radiatoare sunt greu de echilibrat, deoarece accesul simultan la toate \u00eenc\u0103perile este foarte dificil de organizat dac\u0103 acestea sunt ocupate.<\/p>\n<p>\u00cen aceast\u0103 situa\u021bie, este necesar s\u0103 se solicite unei firme de proiectare sau unui expert \u00een echilibrare s\u0103 analizeze re\u021beaua de distribu\u021bie, pentru a stabili posibilit\u0103\u021bile de instalare a unor robinete accesibile de 2<sup>ema<\/sup> nivel.<br \/>Trebuie men\u021bionat c\u0103 echilibrarea circuitului va fi cu at\u00e2t mai eficient\u0103 cu c\u00e2t num\u0103rul de emi\u021b\u0103toare \u00abcontrolate\u00bb de robinetele de 2<sup>ema<\/sup> Nivelul va fi moderat, cu un num\u0103r optim de 5 p\u00e2n\u0103 la 10 unit\u0103\u021bi.<\/p>\n<p>\u00cen general, \u00een cazul instala\u021biilor existente, singura reglare a 2<sup>ema<\/sup> Nivelul de echilibrare (\u0219i nivelurile superioare) sunt suficiente pentru ob\u021binerea unui rezultat corect. Dac\u0103 totu\u0219i ar persista anomalii la anumite antene, va fi \u00eentotdeauna posibil s\u0103 se efectueze local o echilibrare suplimentar\u0103. Aceasta se va putea realiza corect, deoarece grupul de emi\u021b\u0103toare corespunz\u0103tor va fi fost alimentat \u00een prealabil \u00een mod normal, prin reglarea corect\u0103 a robinetului s\u0103u de 2<sup>ema<\/sup> nivel.<\/p>\n<p>Dac\u0103 se instaleaz\u0103 robinete de echilibrare de 2<sup>ema<\/sup> Dac\u0103 acest nivel nu poate fi atins, va trebui s\u0103 se ia \u00een considerare un plan complex de acces la toate spa\u021biile.<br \/>Dac\u0103 tot ne-am hot\u0103r\u00e2t s\u0103 opt\u0103m pentru aceast\u0103 solu\u021bie costisitoare, am putea profita de ocazie pentru a analiza posibilitatea instal\u0103rii unei genera\u021bii noi de robinete termostatice, capabile s\u0103 asigure, de altfel, un echilibrare \u00abdinamic\u0103\u00bb, ale c\u0103rei avantaje le vom analiza ulterior.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinete termostatice hidraulice dinamice Danfoss\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec3.jpg\" alt=\"\" width=\"300\" height=\"251\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura 3: Robine\u021bi termostatici cu ac\u021biune hidraulic\u0103 dinamic\u0103 <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">\u00cen concluzie, trebuie men\u021bionat c\u0103 reglarea acestor robinete necesit\u0103, la fel ca \u00een cazul tuturor robinetelor de echilibrare, o reglare hidraulic\u0103 ini\u021bial\u0103 precis\u0103.<br \/>Dup\u0103 cum vom vedea mai t\u00e2rziu, dac\u0103 echilibrarea se realizeaz\u0103 prin reglarea debitelor, determinarea acestora va necesita, \u00een absen\u021ba documenta\u021biei privind instala\u021biile existente, interven\u021bia unui birou de proiectare.<\/p>\n<p class=\"text-justify push-top\">\u00a0<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANALIZA \u0218I EXPERIEN\u021aA INDUSTRIALILOR<\/h2>\n<\/div>\n<p class=\"text-justify push-top\"><em>Exist\u0103 trei genera\u021bii de robinete de echilibrare.<\/em><\/p>\n<p><strong>1<sup>era<\/sup> genera\u021bie: Robinetele sau supapele de echilibrare statice \u0219i nevolumetrice.<\/strong><br \/>Aceste robinete nu permit m\u0103surarea debitelor \u00een timpul func\u021bion\u0103rii.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinete de echilibrare nevolumetrice\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec18.jpg\" alt=\"\" width=\"650\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\"><em>Figura 4: Robine\u021bi de echilibrare nevolumetrici<\/em><\/p>\n<p class=\"text-justify push-top\">Exist\u0103 dou\u0103 metode de reglare a acestora:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Simularea hidraulic\u0103 a distribu\u021biilor<\/li>\n<li class=\"pad5\">Uniformizarea temperaturilor de retur ale antenelor care trebuie echilibrate<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Simularea hidraulic\u0103 a re\u021belelor de distribu\u021bie presupune \u00eenregistrarea detaliat\u0103 a re\u021belei (lungimile tronsoanelor, diametrele etc.), determinarea comportamentului hidraulic al robinetelor instalate \u0219i calcularea debitelor care trebuie reglate pe fiecare ramifica\u021bie.<br \/>\u00cen cazul instala\u021biilor existente, colectarea tuturor acestor date este o sarcin\u0103 complex\u0103, iar incertitudinile care decurg din aceasta limiteaz\u0103 \u0219ansele de a ob\u021bine cu u\u0219urin\u021b\u0103 un rezultat satisf\u0103c\u0103tor.<\/p>\n<p>Atunci c\u00e2nd instala\u021biile sunt echipate cu robinete de acest tip, cea mai bun\u0103 solu\u021bie este s\u0103 se procedeze astfel: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/methode-dequilibrage-equilog\/\" target=\"_blank\" rel=\"noopener noreferrer\">uniformizarea temperaturilor apei de retur ale sistemelor care urmeaz\u0103 s\u0103 fie echilibrate. <\/a><br \/>Aceast\u0103 metod\u0103 recent\u0103 va fi prezentat\u0103 mai jos.<\/p>\n<p><strong>2<sup>ema<\/sup> Genera\u021bie: Robinetele sau supapele de echilibrare statice \u0219i volumetrice.<\/strong><br \/>Aceste robinete permit m\u0103surarea debitelor \u00een timpul curgerii.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinete de echilibrare volumetric\u0103\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec5.jpg\" alt=\"\" width=\"451\" height=\"230\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 5: Robine\u021bi de echilibrare volumetric\u0103 <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> \u0219i <a class=\"bleu\" href=\"http:\/\/www.comap.fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">Comap<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Exist\u0103 trei metode de reglare a acestora:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Simularea hidraulic\u0103 a distribu\u021biilor<\/li>\n<li class=\"pad5\">Reglarea \u0219i controlul debitelor prin m\u0103surare la fa\u021ba locului<\/li>\n<li class=\"pad5\">Uniformizarea temperaturilor apei de retur ale sistemelor care urmeaz\u0103 s\u0103 fie echilibrate<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Dac\u0103 excludem prima solu\u021bie, av\u00e2nd \u00een vedere dificult\u0103\u021bile pe care le prezint\u0103 \u00een cazul instala\u021biilor existente, trebuie remarcat faptul c\u0103 reglarea debitelor necesit\u0103, de asemenea, interven\u021bia unui birou de proiectare pentru determinarea debitului care trebuie reglat pe fiecare anten\u0103 ce urmeaz\u0103 s\u0103 fie echilibrat\u0103.<br \/>\u00cen cazul instala\u021biilor existente, cea mai simpl\u0103 solu\u021bie r\u0103m\u00e2ne uniformizarea temperaturilor apei de retur.<\/p>\n<p><strong>3<sup>ema<\/sup> genera\u021bie: Robinetele sau supapele de echilibrare dinamic\u0103<\/strong><br \/>Fiind ultima genera\u021bie de robinete de echilibrare, acestea sunt destinate instal\u0103rii pe <strong>circuitele cu debit variabil <\/strong>cum ar fi cele dotate cu robinete termostatice.<\/p>\n<p>Trebuie s\u0103 facem distinc\u021bia \u00eentre dou\u0103 tipuri de robinete:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Robinetele sau supapele de echilibrare \u00ab <em>regulatoare de presiune diferen\u021bial\u0103 <\/em>\u00bb<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinete de reglare a presiunii diferen\u021biale\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec7.jpg\" alt=\"\" width=\"650\" height=\"207\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 6: Robinete de reglare a presiunii diferen\u021biale <a class=\"bleu\" href=\"http:\/\/honeywell.com\/country\/fr\/Pages\/home.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">Honeywell<\/a> \u0219i <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">\u00centr-o re\u021bea echipat\u0103 cu robinete termostatice (Rth), atunci c\u00e2nd acestea se \u00ab\u00eenchid\u00bb, diferen\u021ba de presiune de alimentare (DP) a ramifica\u021biei cre\u0219te. Aceast\u0103 cre\u0219tere a DP se opune \u00eenchiderii Rth \u0219i duce la cre\u0219terea debitului \u00een emi\u021b\u0103toarele ale c\u0103ror robinete termostatice nu s-au \u00eenchis \u00eenc\u0103.<br \/>\u00cen aceast\u0103 situa\u021bie, robinetul de reglare a presiunii diferen\u021biale detecteaz\u0103 cre\u0219terea presiunii diferen\u021biale \u0219i se \u00ab\u00eenchide\u00bb pentru a o restabili.<\/p>\n<p>Anumite modele, precum cele din fotografia de mai sus, nu sunt volumetrice \u0219i, prin urmare, nu permit m\u0103surarea debitelor reglate. Reglarea acestora sau verificarea regl\u0103rii lor trebuie efectuat\u0103 prin m\u0103surarea temperaturilor de retur.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>ema<\/sup> Tipuri de robinete de echilibrare dinamic\u0103: Robinetele de echilibrare automate<\/strong> <em>(denumite \u0219i auto-echilibrante sau independente de presiunea de alimentare, sau PIBCV, sau regulatoare de debit)<\/em><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinete de echilibrare denumite \u00abautomate\u00bb\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec8.jpg\" alt=\"\" width=\"250\" height=\"253\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 7: Robine\u021bi de echilibrare denumi\u021bi \u00abautomatici\u00bb <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Aceste robinete au fost concepute pentru a permite <strong>configurarea unui singur terminal<\/strong> cum ar fi un element de \u00eenc\u0103lzire al unui CTA sau al unui ventiloconvector.<br \/>Acestea pot fi motorizate, permi\u021b\u00e2nd astfel reglarea unit\u0103\u021bii \u00een cele mai bune condi\u021bii de func\u021bionare hidraulic\u0103.<\/p>\n<p>Acestea sunt uneori utilizate pentru a asigura echilibrarea antenelor care con\u021bin <strong>mai multe emi\u021b\u0103toare echipate cu supape de reglare cu dou\u0103 c\u0103i<\/strong> cum ar fi radiatoarele echipate cu robinete termostatice. Robinetele de echilibrare automate \u00eenlocuiesc astfel robinetele de reglare a presiunii diferen\u021biale prev\u0103zute \u00een mod normal pentru aceast\u0103 situa\u021bie.<\/p>\n<p>Aceast\u0103 situa\u021bie nu a fost prev\u0103zut\u0103 ini\u021bial \u0219i nu este men\u021bionat\u0103 \u00een specifica\u021biile tehnice ale produc\u0103torilor. \u00centr-adev\u0103r, func\u021bionarea robinetului de echilibrare automat\u0103 nu este atunci tocmai optim\u0103 \u0219i, \u00een aceast\u0103 situa\u021bie, se aseam\u0103n\u0103 cu cea a unui robinet de echilibrare static.<\/p>\n<p>Putem analiza acest mod de func\u021bionare consult\u00e2nd articolul: <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u00abEchilibrarea automat\u0103: condi\u021biile succesului\u00bb<\/a><\/p>\n<p>\u00cen comentariile de la sf\u00e2r\u0219itul acestui articol se va remarca punctul de vedere al celor doi mari produc\u0103tori.<br \/>Astfel, IMI \u2013 Hydronic precizeaz\u0103:<br \/><em>\u00ab\u00cen ceea ce prive\u0219te instalarea supapelor automate (PIBCV, \u00een acest caz un regulator de debit) \u00een re\u021belele cu debit variabil (de exemplu, locuin\u021be echipate cu robinete termostatice), calitatea noastr\u0103 de exper\u021bi sau de speciali\u0219ti din industria hidraulic\u0103 ne impune s\u0103 adopt\u0103m o abordare impecabil\u0103 din punct de vedere tehnic. Chiar dac\u0103 trebuie s\u0103 constat\u0103m c\u0103 instalarea PIBCV la intrarea \u00een locuin\u021be este \u00een cre\u0219tere, din punct de vedere etic nu putem \u00eencuraja aceast\u0103 practic\u0103.\u00bb<\/em><\/p>\n<p>Adopt\u00e2nd o abordare mai pragmatic\u0103 \u00een aceea\u0219i privin\u021b\u0103, Oventrop precizeaz\u0103 <em>c\u0103, chiar dac\u0103 exist\u0103 o compromis tehnic \u00een ceea ce prive\u0219te sistemul hidraulic, reglajul general ob\u021binut cu robinetele automate este totu\u0219i mult mai bun dec\u00e2t cel ob\u021binut cu robinetele statice \u0219i robinetele de reglare a presiunii, deoarece acestea din urm\u0103 sunt, de cele mai multe ori, slab reglate sau deloc.<\/em><\/p>\n<p>\u00centr-adev\u0103r, reglarea robinetelor de reglare a presiunii diferen\u021biale las\u0103 adesea de dorit, \u00een special \u00een cazul modelelor care nu sunt volumetrice. Dac\u0103 nu se lucreaz\u0103 pe baza m\u0103sur\u0103torilor temperaturii de retur, reglarea acestora nu se poate efectua dec\u00e2t pe baza unui calcul ipotetic al pierderii de presiune. Dac\u0103 se dore\u0219te realizarea echilibr\u0103rii prin m\u0103surarea debitului, este indispensabil s\u0103 se opteze pentru modele volumetrice, iar mai multe m\u0103rci propun robinete volumetrice adaptabile.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Robinet volumetric echipat cu un robinet Oventrop de reglare a presiunii diferen\u021biale\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec17.jpg\" alt=\"\" width=\"513\" height=\"150\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 6 bis: Robinet volumetric echipat cu un robinet de reglare a presiunii diferen\u021biale <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">A\u0219adar, \u00een concluzie, trebuie s\u0103 re\u021binem mai ales c\u0103 nu trebuie s\u0103 confund\u0103m \u00abinstalarea robinetelor\u00bb cu \u00abreglarea robinetelor\u00bb, indiferent de genera\u021bia modelelor instalate.<\/p>\n<p>La fel ca \u00een cazul genera\u021biilor anterioare, robinetele de echilibrare dinamic\u0103 trebuie s\u0103 fac\u0103 obiectul unei regl\u0103ri ini\u021biale riguroase. Aceast\u0103 reglare se poate efectua prin simulare \u0219i\/sau m\u0103sur\u0103tori ale debitului \u0219i\/sau m\u0103sur\u0103tori ale temperaturilor de retur. Subiectul va fi dezvoltat \u00een paragraful urm\u0103tor.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>METODELE DE ECHILIBRARE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">\u00cen cazul instala\u021biilor de \u00eenc\u0103lzire centralizat\u0103 existente, <strong>trei metodologii <\/strong>\u00cen prezent se utilizeaz\u0103 dispozitive de reglare ini\u021bial\u0103 a robinetelor de echilibrare.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>1<sup>era<\/sup> metod\u0103: Simularea comportamentului hidraulic al re\u021belelor<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Simularea comportamentului hidraulic al re\u021belelor\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec9.jpg\" alt=\"\" width=\"492\" height=\"446\" \/><\/p>\n<p class=\"text-justify push-top\">\u00cen cazul instala\u021biilor existente, este posibil, teoretic, s\u0103 se efectueze m\u0103sur\u0103torile necesare pentru estimarea debitelor \u0219i a pierderilor de presiune din circuite, pentru a deduce prin calcul presetarea robinetelor de echilibrare. Este vorba \u00eens\u0103 de un \u00abjoc de-a v\u00e2n\u0103toarea de comori\u00bb dificil, cu excep\u021bia cazului \u00een care se utilizeaz\u0103 planurile de distribu\u021bie, care sunt rareori disponibile.<\/p>\n<p>Aceast\u0103 posibilitate, dezvoltat\u0103 \u00een mod deosebit de <a class=\"bleu\" href=\"http:\/\/edipa.fr\/LibrairieTechnique\/Auteur?auteur=FRIDMANN%20Pierre&amp;page=1\" target=\"_blank\" rel=\"noopener noreferrer\">Domnul Pierre Fridmann<\/a> presupune posibilitatea de a verifica ulterior rezultatul tuturor preset\u0103rilor efectuate, fie prin m\u0103surarea debitelor, fie prin m\u0103surarea temperaturilor apei de retur.<\/p>\n<p>Aceast\u0103 metod\u0103 se aplic\u0103 mai degrab\u0103 instala\u021biilor noi sau recente, care nu prezint\u0103 \u00eenc\u0103 depuneri neprev\u0103zute \u0219i pentru care sunt disponibile toate datele de calcul necesare.<br \/>Aceasta poate fi utilizat\u0103, \u00een special, pentru a determina diferen\u021bele de presiune care trebuie reglate la robinetele \u00abde reglare a presiunii diferen\u021biale\u00bb prev\u0103zute cu scale de reglare exprimate \u00een unit\u0103\u021bi de presiune.<br \/>Rezultatul simul\u0103rii permite presetarea robinetelor, \u00eenainte ca debitele de ap\u0103 sau temperaturile apei de retur ob\u021binute efectiv s\u0103 fie verificate \u0219i ajustate ulterior la fa\u021ba locului.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>ema<\/sup> metod\u0103: Calculul, reglarea \u0219i controlul debitelor care trebuie transportate<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Metodologia const\u0103 \u00een calcularea \u0219i reglarea debitelor care trebuie transportate. Aceasta necesit\u0103, desigur, prezen\u021ba unor arm\u0103turi denumite \u00abvolumetrice\u00bb, statice sau dinamice, care permit m\u0103surarea debitelor.<br \/>Prin urmare, aceasta nu se aplic\u0103 \u00een cazul <strong>robinete nevolumetrice<\/strong> cum ar fi simplele robinete de reglare montate la ie\u0219irea radiatoarelor, dar \u0219i la baza coloanelor \u0219i, mai ales, pe returul circuitelor de \u00eenc\u0103lzire prin pardoseal\u0103.<\/p>\n<p>S\u0103 reamintim, de asemenea, c\u0103 anumite robinete de reglare a presiunii diferen\u021biale nu sunt volumetrice. Reglarea acestora sau verificarea reglajului lor trebuie efectuat\u0103 exclusiv prin m\u0103surarea temperaturilor de retur.<\/p>\n<p>\u00cen cazul instala\u021biilor existente, pentru determinarea debitelor care trebuie reglate, o firm\u0103 de proiectare va trebui s\u0103 efectueze m\u0103sur\u0103torile necesare pentru estimarea pierderilor corespunz\u0103toare fiec\u0103rei antene de \u00eenc\u0103lzire care urmeaz\u0103 s\u0103 fie tratat\u0103.<br \/>Pentru aceasta, va trebui s\u0103 calculeze pierderile de c\u0103ldur\u0103 ale \u00eenc\u0103perilor standard \u0219i ale celor speciale (sub teras\u0103, l\u00e2ng\u0103 fronton etc.). Apoi, ceea ce este adesea foarte delicat, va trebui s\u0103 le aloce corect fiec\u0103rei antene care trebuie reglat\u0103.<\/p>\n<p>Reglarea debitelor necesit\u0103 utilizarea unui kit de m\u0103surare \u0219i, \u00een cazul \u00een care robinetele nu sunt dinamice, aplicarea unei metodologii specifice.<br \/>Una dintre aceste metode poate fi achizi\u021bionat\u0103 de pe <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-debit.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Eformation Xpair<\/a> sau pe <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulator.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Controlul debitului\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec10.jpg\" alt=\"\" width=\"551\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 9: Controlul debitului \u2013 Surs\u0103 <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> \u0219i trusa de m\u0103surare <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Dac\u0103 robinetele care trebuie reglate sunt<strong> de tip dinamic <\/strong>reglarea debitelor se poate efectua mai u\u0219or, f\u0103r\u0103 a fi necesar\u0103 o metod\u0103 special\u0103, cu excep\u021bia verific\u0103rii faptului c\u0103 robinetul cel mai defavorizat dispune de o presiune diferen\u021bial\u0103 de alimentare suficient\u0103.<\/p>\n<p>La anumite robinete dinamice cu scal\u0103 de debit, presetarea se poate efectua f\u0103r\u0103 m\u0103surare, dar acest lucru nu scute\u0219te de efectuarea m\u0103sur\u0103rii finale a debitelor ob\u021binute dup\u0103 ce toate robinetele au fost presetate.<br \/>\u00cen cazul modelelor care nu sunt gradate \u00een ceea ce prive\u0219te debitul, \u00een special robinetele de reglare a presiunii diferen\u021biale, reglarea debitelor nu poate fi efectuat\u0103 f\u0103r\u0103 m\u0103surarea efectiv\u0103 a acestora (dac\u0103 sunt, de altfel, de tip volumetric).<\/p>\n<p>Odat\u0103 ce toate robinetele dinamice vor fi fost reglate sau prereglate, \u00een cazul \u00een care sunt de tip volumetric, o echilibrare riguroas\u0103 se va \u00eencheia cu m\u0103surarea tuturor debitelor din circuit, pentru a se asigura c\u0103 interac\u021biunile hidraulice dintre ramifica\u021bii au fost tratate corespunz\u0103tor.<br \/>S\u0103 reamintim, \u00eentr-adev\u0103r, c\u0103 sunt suficiente c\u00e2teva antene aflate \u00een condi\u021bii nefavorabile pentru a fi necesar\u0103 supra\u00eenc\u0103lzirea \u00eentregii re\u021bele de distribu\u021bie, iar comportamentul hidraulic al circuitelor, \u00een special al celor existente, rezerv\u0103 adesea multe surprize.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>3<sup>ema<\/sup> metod\u0103: M\u0103surarea \u0219i uniformizarea temperaturilor apei de retur pe durata sezonului de \u00eenc\u0103lzire<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Aceast\u0103 solu\u021bie mai recent\u0103, cunoscut\u0103 sub denumirea de \u00abmetoda EQUILOG\u00bb, const\u0103, \u00een condi\u021biile \u00een care sistemul de \u00eenc\u0103lzire este \u00een func\u021biune \u0219i temperatura de plecare este stabilizat\u0103, \u00een <strong>m\u0103surarea temperaturilor apei de retur <\/strong>antene care trebuie echilibrate \u0219i uniformizate, astfel \u00eenc\u00e2t toate antenele care trebuie reglate s\u0103 fie \u00abla fel de calde\u00bb unele fa\u021b\u0103 de altele.<\/p>\n<p>De\u0219i pare \u00absimplist\u00bb, acest procedeu a fost \u0219i este \u00een continuare \u021binta unor critici fire\u0219ti din partea concuren\u021bilor s\u0103i. Se poate citi pe aceast\u0103 tem\u0103 <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-hydraulique-methode-simple.htm\" target=\"_blank\" rel=\"noopener\">\u00abEchilibrarea hidraulic\u0103: nout\u0103\u021bi privind o metod\u0103 simpl\u0103\u00bb. <\/a>Se poate constata \u00eens\u0103 c\u0103, \u00een c\u00e2teva sute de amplasamente, peste 80 000 de unit\u0103\u021bi echivalente de locuin\u021be au fost gestionate p\u00e2n\u0103 \u00een prezent \u00een condi\u021bii bune de rentabilitate.<\/p>\n<p>Dup\u0103 echilibrare, antenele vor prezenta temperaturi de retur \u0219i diferen\u021be de temperatur\u0103 \u00eentre dus \u0219i retur comparabile <em>(*)<\/em>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Uniformizarea temperaturilor apei dintr-un circuit de \u00eenc\u0103lzire\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec12.gif\" alt=\"\" width=\"573\" height=\"229\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 11: Uniformizarea(*) temperaturilor apei dintr-un circuit de \u00eenc\u0103lzire<\/em><\/p>\n<p class=\"text-justify push-top\"><em>(*) Atunci c\u00e2nd re\u021beaua hidraulic\u0103 permite acest lucru, este, desigur, posibil s\u0103 se regleze temperaturi diferite ale apei pentru fiecare ramifica\u021bie, pentru a \u021bine seama de opera\u021biunile locale de izolare. <\/em><br \/><em>Cu toate acestea, se constat\u0103 c\u0103, \u00een cazul cl\u0103dirilor care au f\u0103cut obiectul unor lucr\u0103ri de renovare termic\u0103 omogene (\u00eenlocuirea tuturor ferestrelor \u0219i u\u0219ilor, izolarea tuturor pere\u021bilor verticali exteriori), echilibrarea <u>ini\u021bial sau ulterior<\/u> ob\u021binut prin uniformizarea temperaturii apei este suficient pentru a ob\u021bine un rezultat bun. <\/em><br \/><em>Reglarea puterii de \u00eenc\u0103lzire se poate efectua apoi prin simpla reglare a temperaturii apei la ie\u0219irea din cazan (reglarea curbei de \u00eenc\u0103lzire).<\/em><\/p>\n<p>Procesul, aplicabil tuturor tipurilor de robinete, a putut fi optimizat gra\u021bie progreselor \u00eenregistrate \u00een domeniul termometriei \u00een infraro\u0219u \u0219i cercet\u0103rilor efectuate de GMTI94 \u2013 GEFEn.<br \/>Principiul s\u0103u poate fi studiat pe <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-temp.htm\" target=\"_blank\" rel=\"noopener noreferrer\">Eformation Xpair<\/a> sau pe <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulator<\/a>.<\/p>\n<p>Principalul avantaj al acestei metodologii este acela c\u0103 permite renun\u021barea la toate calculele privind pierderile sau la \u00eenregistr\u0103rile privind instala\u021biile \u00een cazul re\u021belelor dimensionate corespunz\u0103tor. Prin urmare, aceasta este deosebit de potrivit\u0103 pentru circuitele existente, pentru care rareori sunt disponibile date istorice.<\/p>\n<p>Pus\u0103 \u00een practic\u0103 \u00een mod experimental \u00een anii 2000, aceast\u0103 procedur\u0103 a fost brevetat\u0103 \u00een Fran\u021ba \u0219i, recent, \u00een 15 \u021b\u0103ri europene.<br \/>Metoda \u00abEQUILOG\u00bb este aplicat\u0103, \u00een special, de c\u0103tre <em>\u00ab <\/em><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><em>societatea MAPSEC <\/em><\/strong><\/a><em>\u00bb(*) <\/em>pentru diverse societ\u0103\u021bi de exploatare \u0219i instalare (Dalkia, Cofely-Soccram, Idex etc.).<br \/><em>(*) MAPSEC, 80 rue de Paris, 93100 Montreuil, Tel.: 01 48 59 06 05 \u2013 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr<\/a><\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Pomp\u0103 de circula\u021bie\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec11.jpg\" alt=\"\" width=\"250\" height=\"187\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Figura nr. 10: Controlul temperaturii apei Surs\u0103 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/\" target=\"_blank\" rel=\"noopener noreferrer\">Mapsec<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">S\u0103 men\u021bion\u0103m, \u00een sf\u00e2r\u0219it, c\u0103 \u00een <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">articolul dedicat robinetelor de echilibrare dinamic\u0103<\/a> a\u0219a cum s-a men\u021bionat \u00een paragraful anterior, inginerul reprezentant al Oventrop precizeaz\u0103 acest lucru \u00een comentariile de la sf\u00e2r\u0219itul dosarului.<br \/><em>\u00ab\u00cen ceea ce prive\u0219te instala\u021bia existent\u0103, echilibrarea prin uniformizarea temperaturilor de retur este, \u00een opinia mea, cea mai bun\u0103 metod\u0103, cu condi\u021bia ca diferen\u021ba de temperatur\u0103 aleas\u0103 s\u0103 fie cea potrivit\u0103.\u201d.<br \/>Cu toate acestea, aceast\u0103 metod\u0103 este consumatoare de timp \u0219i este greu acceptat\u0103 de instalatorii specializa\u021bi \u00een locuin\u021be atunci c\u00e2nd trebuie efectuat\u0103 manual.<br \/>\u00bbExist\u0103 robinete care fac asta automat, dar pre\u021bul nu este acela\u0219i\u201d<\/em><\/p>\n<p>\u00centr-adev\u0103r, echilibrarea prin uniformizarea temperaturilor de retur necesita \u00een trecut perioade lungi de a\u0219teptare pentru stabilizarea termic\u0103, dar ultimele progrese realizate permit ast\u0103zi s\u0103 se renun\u021be la acestea, iar durata opera\u021biunilor a devenit foarte competitiv\u0103.<\/p>\n<p>De altfel, s-ar putea lua \u00een considerare, \u00eentr-adev\u0103r, realizarea \u0219i men\u021binerea pe termen lung a echilibr\u0103rii prin uniformizarea temperaturilor de retur. \u00cens\u0103, la stadiul actual al tehnologiei, acest lucru ar necesita instalarea \u0219i alimentarea cu energie electric\u0103 a unor robinete de echilibrare automate, motorizate \u0219i conectate la un controler automat sau la un sistem de gestionare a climei (GTB).<br \/>Din punct de vedere economic, acest lucru r\u0103m\u00e2ne, deocamdat\u0103, greu de imaginat, cel pu\u021bin \u00een cazul instala\u021biilor existente.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANALIZA \u0218I EXPERIEN\u021aA INSTALATORILOR<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Este esen\u021bial s\u0103 se fac\u0103 o distinc\u021bie clar\u0103 \u00eentre opera\u021biunile de cur\u0103\u021bare a depunerilor (atunci c\u00e2nd este necesar) \u0219i cele de instalare a robinetelor de echilibrare, pe de o parte, \u0219i reglarea ini\u021bial\u0103 propriu-zis\u0103 a acestora, pe de alt\u0103 parte.<\/p>\n<p>\u00centr-adev\u0103r, indiferent de tipul de robinet, o firm\u0103 specializat\u0103 \u00een instalare sau cur\u0103\u021bare este tentat\u0103 s\u0103 includ\u0103 \u00een oferta sa serviciul de punere \u00een func\u021biune, f\u0103r\u0103 a fi \u00eentotdeauna \u00een m\u0103sur\u0103 s\u0103 defineasc\u0103 to\u021bi parametrii acestuia.<\/p>\n<p>Desigur, ne putem imagina c\u0103 o singur\u0103 companie ar putea gestiona \u00een \u00eentregime o opera\u021biune de reechilibrare, dar, \u00een acest caz, ea trebuie s\u0103 dispun\u0103 de echipe cu competen\u021be foarte diverse, at\u00e2t practice, c\u00e2t \u0219i teoretice.<\/p>\n<p>\u00cen general, va trebui, a\u0219adar, s\u0103 se dea dovad\u0103 de o pruden\u021b\u0103 extrem\u0103 \u00een alegerea unei companii care urmeaz\u0103 s\u0103 efectueze o opera\u021biune de echilibrare. Este vorba de o specialitate tehnic\u0103 dificil\u0103, iar cazurile de performan\u021be slabe sunt numeroase, deoarece verificarea calit\u0103\u021bii lucr\u0103rilor efectuate este dificil de realizat.<\/p>\n<p>Chiar dac\u0103 acest lucru ar implica costuri suplimentare, nu vom ezita s\u0103 separ\u0103m interven\u021biile astfel \u00eenc\u00e2t fazele de studiu \u0219i\/sau de punere la punct s\u0103 fie realizate de speciali\u0219ti \u00een domeniu.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radiator\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec13.jpg\" alt=\"\" width=\"450\" height=\"173\" \/><\/p>\n<p class=\"text-justify push-top\">O modalitate bun\u0103 de selec\u021bie este aceea de a \u00eentreba, \u00een cadrul consulta\u021biei, ce tip de metod\u0103 va fi utilizat\u0103 \u0219i de a cere s\u0103 vi se precizeze clar ce date vor fi furnizate dup\u0103 opera\u021bie.<br \/>Orice neclaritate sau ezitare \u00een r\u0103spunsurile date cu privire la oricare dintre aceste dou\u0103 puncte va fi, f\u0103r\u0103 \u00eendoial\u0103, un semn al unei presta\u021bii slab st\u0103p\u00e2nite.<\/p>\n<p>Dac\u0103 \u00eentreprinderea lucreaz\u0103 pe baza m\u0103sur\u0103rii debitului sau a simul\u0103rii hidraulice, se poate solicita ca oferta s\u0103 includ\u0103 reducerea final\u0103:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Calculul detaliat al pierderilor <strong>\u00een func\u021bie de fiecare robinet care urmeaz\u0103 s\u0103 fie tratat<\/strong> \u0219i care au condus la stabilirea debitelor care trebuie achitate. Astfel, se va putea asigura c\u0103 debitele vizate nu sunt rezultatul unor estim\u0103ri aproximative.<\/li>\n<li class=\"pad5\">Dintr-o gril\u0103 <strong>certificat\u0103<\/strong> debitele m\u0103surate <u>dup\u0103 ce s-au reglat toate robinetele<\/u> (\u0219i s\u0103 nu ne mul\u021bumim doar cu tabelul debitelor prev\u0103zute teoretic). Astfel, ne vom putea asigura c\u0103 interac\u021biunile hidraulice dintre antenele care trebuie reglate au fost efectiv luate \u00een considerare \u0219i, dac\u0103 este necesar, vom putea verifica acest lucru.<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">\u00cen cazul \u00een care \u00eentreprinderea utilizeaz\u0103 m\u0103surarea temperaturilor de retur, se poate solicita ca oferta s\u0103 includ\u0103:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">C\u00e2teva referin\u021be relevante sau, mai bine zis, prezentarea a cel pu\u021bin unui raport detaliat privind o opera\u021biune efectuat\u0103 anterior. Astfel, se va putea verifica experien\u021ba candidatului, deoarece, de\u0219i principiul metodei este vechi, aceasta este st\u0103p\u00e2nit\u0103 cu adev\u0103rat abia de cur\u00e2nd.<\/li>\n<li class=\"pad5\">Reprezentarea grafic\u0103 a unui grafic <strong>certificat, complet \u0219i detaliat<\/strong> temperaturile de retur m\u0103surate,<strong> \u00eenainte \u0219i dup\u0103 echilibrare<\/strong>, cu indicarea temperaturilor de plecare stabilizate la care au fost efectuate aceste m\u0103sur\u0103tori. Astfel, se va putea verifica calitatea lucr\u0103rii realizate.<\/li>\n<\/ul>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>RENTABILITATE \u0218I ECONOMII DE ENERGIE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Nu este u\u0219or s\u0103 se estimeze economiile de energie care se pot ob\u021bine \u00een urma unei opera\u021biuni de echilibrare.<br \/>\u00centr-adev\u0103r, de\u0219i \u00een cazul unui echilibrare realizat\u0103 perfect, aceasta poate fi estimat\u0103 pe baza unei h\u0103r\u021bi a temperaturilor ini\u021biale ale mediului \u00eenconjur\u0103tor, aceasta este, de fapt, foarte greu de interpretat.<br \/>\u00cen orice caz, dac\u0103 se opteaz\u0103 pentru aceast\u0103 metod\u0103 de estimare, trebuie s\u0103 se ia \u00een considerare \u00eenregistr\u0103rile efectuate \u00een perioade foarte reci \u0219i \u00een absen\u021ba oric\u0103rui aport gratuit (lumina soarelui, echipamente electrice etc.), \u0219i nu m\u0103sur\u0103torile instantanee.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Exemplu de \u00eenregistrare a temperaturilor ambientale perturbate de aporturile gratuite\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec15.jpg\" alt=\"\" width=\"400\" height=\"235\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Fig. 15: Exemplu de \u00eenregistrare a temperaturilor ambientale perturbate de aporturile gratuite<\/em><\/p>\n<p class=\"text-justify push-top\">\u00cens\u0103 un aspect \u0219i mai delicat este luarea \u00een considerare a amplas\u0103rii robinetelor de echilibrare care pot fi efectiv reglate. \u00centr-adev\u0103r, \u00een instala\u021biile de \u00eenc\u0103lzire existente, echilibrarea se realizeaz\u0103, de obicei, doar pe robinetele accesibile de la etajul 2<sup>ema<\/sup> nivel (vezi 2<sup>ema<\/sup> \u00a7). \u00cen consecin\u021b\u0103, gradul mai mult sau mai pu\u021bin bun de implementare a acestui 2<sup>ema<\/sup> Nivelul este un parametru esen\u021bial pentru estimarea economiei de energie preconizate.<\/p>\n<p>\u00cen aceast\u0103 privin\u021b\u0103, compania MAPSEC utilizeaz\u0103 o metodologie cunoscut\u0103 sub numele de <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/ecomapsec\/\" target=\"_blank\" rel=\"noopener noreferrer\">REQUILOG<\/a> care \u00eei permite, pe baza unei h\u0103r\u021bi a temperaturilor apei de retur m\u0103surate la nivelul robinetelor care urmeaz\u0103 s\u0103 fie reglate, s\u0103 evalueze amploarea dezechilibrului care poate fi efectiv remediat.<br \/>De asemenea, atunci c\u00e2nd este posibil, opera\u021biunile de echilibrare care \u00eei sunt \u00eencredin\u021bate sunt precedate de o opera\u021biune de diagnosticare care include aceast\u0103 evaluare, ceea ce permite factorului de decizie s\u0103 aprecieze mai bine oportunitatea de a efectua sau nu opera\u021biunea respectiv\u0103.<\/p>\n<p>\u00cen cele din urm\u0103, trebuie men\u021bionat c\u0103 economia de energie rezultat\u0103 \u00een urma unei opera\u021biuni de echilibrare va necesita implicarea ulterioar\u0103 a tehnicianului responsabil cu reglarea sistemului de control.<br \/>\u00centr-adev\u0103r, dac\u0103 echilibrarea ar \u00eensemna, \u00een final, s\u0103 aducem locuin\u021bele care ini\u021bial erau cel mai slab \u00eenc\u0103lzite la nivelul celor mai bine \u00eenc\u0103lzite, nu s-ar ob\u021bine o economie de energie\u2026<\/p>\n<p>\u00cen ansamblu, se pare c\u0103 valoarea medie a economiilor de energie % dup\u0103 reechilibrarea sistemelor de distribu\u021bie a c\u0103ldurii este de aproximativ 7%, cu o perioad\u0103 de amortizare de aproximativ 2-3 ani, \u00een cazul \u00een care circuitul nu necesit\u0103 \u00eenlocuirea robinetelor sau necesit\u0103 doar o \u00eenlocuire minim\u0103 a acestora.<\/p>\n<p>P\u00e2n\u0103 \u00een decembrie 2014, aceste opera\u021biuni puteau fi incluse \u00een sistemul Certificatelor de Economie Energetic\u0103 pentru un procent forfetar de economie energetic\u0103 de 10%.<br \/>Fi\u0219ele BAR \u0219i BAT SE 04 corespunz\u0103toare sunt \u00een prezent \u00een curs de modificare. Acestea ar trebui s\u0103 reapar\u0103 sub alte denumiri \u00een urm\u0103torul decret ministerial dedicat CEE.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"butonul ECO\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec14.jpg\" alt=\"\" width=\"250\" height=\"180\" \/><\/p>\n<p class=\"text-justify push-top\">\u00cen concluzie, un lucru este cert: opera\u021biunile de echilibrare sunt, \u00een ansamblu, extrem de rentabile dac\u0103 sunt efectuate cu rigurozitate.<\/p>\n<p>Cea mai bun\u0103 dovad\u0103 \u00een acest sens o constituie activitatea desf\u0103\u0219urat\u0103 de serviciul de echilibrare al companiei Dalkia din IdF(*), \u00eenfiin\u021bat \u00een urm\u0103 cu aproximativ zece ani pentru a pune \u00een aplicare metoda EQUILOG \u0219i condus \u00een prezent de domnul Christophe Tillay.<br \/>Pe Xpair se va putea citi relatarea uneia dintre realiz\u0103rile sale \u00een articolul <a class=\"bleu\" href=\"http:\/\/conseils.xpair.com\/actualite_experts\/exemple-operation-equilibrage-egalisation-temperatures-retour.htm\" target=\"_blank\" rel=\"noopener noreferrer\">\u00abOpera\u021biune de echilibrare prin uniformizarea temperaturilor de retur\u00bb.<\/a><\/p>\n<p><em>(*) Dalkia Ile-de-France, Serviciul de echilibrare, 28 Boulevard de Pesaro, 92 751 NANTERRE CEDEX Tel.: 01 55 67 68 97 <\/em><\/p>\n<p>Cele c\u00e2teva sute de opera\u021biuni de echilibrare efectuate de acest serviciu au vizat exclusiv ansamblurile imobiliare gestionate de societate \u00een cadrul contractelor MF (contract forfetar) sau MT (contract de temperatur\u0103). \u00cen cazul acestui tip de contracte, care nu sunt suficient de r\u0103sp\u00e2ndite, clientul pl\u0103te\u0219te anual operatorului o sum\u0103 forfetar\u0103 (sau ajustat\u0103 \u00een func\u021bie de DJU) \u00een schimbul garan\u021biei unei \u00eenc\u0103lziri optime.<\/p>\n<p>Aprovizionarea cu combustibil este, a\u0219adar, \u00een \u00eentregime \u00een sarcina societ\u0103\u021bii de exploatare. Interesul s\u0103u principal este, prin urmare, acela de a reduce consumul, f\u0103r\u0103 a afecta calitatea \u00eenc\u0103lzirii pentru client, \u00eentruc\u00e2t toate economiile de energie realizate \u00eei vor reveni \u00een totalitate.<\/p>\n<p>Acest tip de contract \u00eel \u00eencurajeaz\u0103, desigur, pe prestator s\u0103 gestioneze instala\u021bia c\u00e2t mai bine posibil \u0219i s\u0103 aloce pentru aceasta cele mai bune echipe ale sale. Din punct de vedere ecologic, situa\u021bia este astfel optim\u0103.<br \/>La r\u00e2ndul s\u0103u, f\u0103r\u0103 costuri suplimentare deosebite, clientul are garan\u021bia unui sistem de \u00eenc\u0103lzire durabil \u0219i bine reglat, precum \u0219i garan\u021bia c\u0103, la expirarea contractelor \u2013 care au, de obicei, o durat\u0103 de 8 ani \u2013, va prelua o instala\u021bie \u00eentre\u021binut\u0103 c\u00e2t se poate de bine.<\/p>\n<p>Prin urmare, lucr\u0103rile de echilibrare realizate de departamentul de echilibrare al Dalkia IdF au fost finan\u021bate din fonduri proprii \u0219i amortizate \u00een c\u00e2\u021biva ani datorit\u0103 economiilor de energie generate.<br \/>Men\u021binerea \u0219i dezvoltarea acestui serviciu pe o perioad\u0103 de 10 ani constituie o dovad\u0103 incontestabil\u0103 a rentabilit\u0103\u021bii ridicate a acestui tip de opera\u021biuni.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Graficul de echilibrare\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec16.jpg\" alt=\"\" width=\"400\" height=\"250\" \/><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\" style=\"text-align: left;\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>CONCLUZIE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\" style=\"text-align: left;\">Reducerea consumului de energie al parcului nostru existent de sisteme de \u00eenc\u0103lzire colectiv\u0103 se bazeaz\u0103 pe izola\u021bie, pe reglarea corect\u0103 a arderii, pe reglarea sistemului de control \u0219i pe echilibrarea sistemului.<\/p>\n<p style=\"text-align: left;\">\u00cen ciuda influen\u021bei sale majore asupra regl\u0103rii \u0219i randamentului cazanelor cu condensare (\u0219i al sistemelor de cogenerare), acest ultim element a reprezentat p\u00e2n\u0103 acum veriga slab\u0103.<\/p>\n<p style=\"text-align: left;\">Dup\u0103 o pauz\u0103 foarte lung\u0103, problema nu a fost niciodat\u0103 at\u00e2t de actual\u0103.<\/p>\n<p style=\"text-align: left;\">Progresele recente \u00een domeniul arm\u0103turilor \u0219i al optimiz\u0103rii ar trebui s\u0103 permit\u0103 valorificarea mai eficient\u0103 a uneia dintre cele mai importante surse de economisire a energiei \u00eenc\u0103 disponibile.<\/p>\n<\/div>\n<h4 class=\"text-primary push-top\" style=\"text-align: left;\"><strong>SURSE \u0218I LINK-URI<\/strong><\/h4>\n<ul class=\"push-top\">\n<li class=\"pad10\" style=\"text-align: left;\">PRECIZARE: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/precizare\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mise-au-point<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">PUNEREA \u00ceN FUNC\u021aIUNE A SISTEMELOR HVAC: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/commissioning\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/commissioning<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">AUDIT PE TEREN: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/audit\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/audit<\/a><\/li>\n<li style=\"text-align: left;\">TEST DE ETAN\u0218EITATE Re\u021bele de ventila\u021bie:\u00a0<a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mesure-de-letancheite-a-lair-des-reseaux-aeraulique<\/a><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/ro\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">s<\/a><\/li>\n<li style=\"text-align: left;\">SIMULATOR \u00cenv\u0103\u021barea echilibr\u0103rii: <a href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564\" target=\"_blank\" rel=\"noopener\">www.edipa.fr\/LibrairieTechnique\/Details\/564<\/a><\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Par Patrick DELPECH &#8211; pour la soci\u00e9t\u00e9 MAPSEC &#8211; Mars 2020 Pour les responsables techniques et d\u00e9cideurs (maitres d\u2019ouvrage, syndic, etc.), les nouveaut\u00e9s du secteur, les<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16263","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/posts\/16263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/comments?post=16263"}],"version-history":[{"count":4,"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/posts\/16263\/revisions"}],"predecessor-version":[{"id":17284,"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/posts\/16263\/revisions\/17284"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/media?parent=16263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/categories?post=16263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/ro\/wp-json\/wp\/v2\/tags?post=16263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}