{"id":16263,"date":"2015-09-01T17:36:27","date_gmt":"2015-09-01T16:36:27","guid":{"rendered":"http:\/\/www.mapsec.fr\/?p=16263"},"modified":"2026-06-29T16:46:06","modified_gmt":"2026-06-29T14:46:06","slug":"vse-o-avtomatskem-staticnem-hidravlicnem-uravnotezenju","status":"publish","type":"post","link":"https:\/\/mapsec.fr\/sl\/2015\/09\/01\/tout-sur-lequilibrage-hydraulique-statiqueautomatique\/","title":{"rendered":"Vse o stati\u010dnem in avtomatskem hidravli\u010dnem uravnote\u017eenju"},"content":{"rendered":"<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-white-color has-luminous-vivid-orange-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/mapsec.fr\/sl\/kontakt\/\" style=\"border-radius:2px\">zahtevati ponudbo <\/a><\/div>\n<\/div>\n\n\n<p class=\"text-right small\" style=\"text-align: right;\">Avtor: Patrick DELPECH \u2013 za podjetje MAPSEC \u2013 marec 2020<\/p>\n<p class=\"text-justify push-top\" style=\"text-align: left;\"><em>Za tehni\u010dne vodje in nosilce odlo\u010ditev (naro\u010dnike, upravitelje stanovanjskih objektov itd.): novosti v panogi, pasti, ki se jim je treba izogniti, ter pogoji za uspe\u0161no izvedbo hidravli\u010dnega in toplotnega uravnote\u017eenja.<\/em><\/p>\n<p>Na tej strani so predstavljena splo\u0161na na\u010dela stati\u010dnega in avtomatskega hidravli\u010dnega uravnote\u017eenja.<\/p>\n<p>\u010ce \u017eelite spoznati metodo MAPSEC, ki se uporablja v sistemih daljinskega ogrevanja, vklju\u010dno z diagnozo, meritvami, nastavitvami, preverjanjem ter metodo EQUILOG, obi\u0161\u010dite na\u0161o glavno stran, posve\u010deno\u2019<a href=\"https:\/\/mapsec.fr\/sl\/2016\/01\/13\/hidravlicno-uravnotezenje-ogrevalnega-sistema-brezplacna-diagnostika\/\">hidravli\u010dno uravnote\u017eenje skupnega ogrevalnega sistema<\/a>.<\/p>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>PROBLEMATIKA<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">V istem ogrevalnem krogu je so\u010dasna prisotnost preve\u010d ogrevanih in premalo ogrevanih prostorov znak zelo pogostega neusklajenega delovanja sistema.<br \/>Ne glede na dejanski vzrok \u2013 napa\u010dna hidravli\u010dna nastavitev, napake pri dimenzioniranju, neenotna izolacija itd. \u2013 je mogo\u010de te\u017eavo odpraviti z nastavitvijo tako imenovanih izravnalnih ventilov, \u010de so ti pravilno razporejeni in dovolj dostopni.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Regulacijski T-kos in volumetri\u010dni ventil\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec1.jpg\" alt=\"\" width=\"529\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 1: Nastavljivi T-kos in volumetri\u010dni ventil <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Nastavitev, ki jo je treba opraviti, vklju\u010duje omejitev pretoka na ventilih prednostnih anten, tako da se ob zmanj\u0161anju njihovega pretoka pove\u010da pretok na neugodnih antenah.<\/p>\n<p>Na\u010delo uravnavanja je torej enostavno razumeti, njegova izvedba pa je precej zahtevnej\u0161a. V tem prispevku je podrobno opisano, pod kak\u0161nimi pogoji bo hidravli\u010dno uravnavanje potekalo pravilno, zlasti v obstoje\u010dih napravah.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANALIZA IN STROKOVNO ZNANJE PROJEKTNIH BIROV<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Na splo\u0161no velja, da je razvod ogrevalne vode <strong>obstoje\u010da<\/strong> se lahko enostavno uravnava le, \u010de so name\u0161\u010dene uravnalne ventile <u>dostopni<\/u>, zunaj zasedenih prostorov.<br \/>\u010ce naprava ni preve\u010d stara, so to obi\u010dajno predvideli projektanti \u017ee ob na\u010drtovanju naprave z vgradnjo tako imenovanih 2-pal\u010dnih ventilov<sup>tema<\/sup> na izravnalni ravni, ki se nahajajo v kletnih prostorih, sanitarnih prostorih ali celo v stopni\u0161\u010dih, v vsakem primeru pa zunaj zasedenih prostorov.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Ventili za izravnavo 2. stopnje \" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec2.jpg\" alt=\"\" width=\"650\" height=\"357\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika 2: 2 pipe<sup>tema<\/sup> stopnja uravnote\u017eenosti<\/em><\/p>\n<p class=\"text-justify push-top\">Krogi, v katerih so na radiatorjih name\u0161\u010dene le izravnalne pipe, je te\u017eko izravnati, saj je hkratni dostop do vseh prostorov zelo te\u017eko organizirati, \u010de so ti zasedeni.<\/p>\n<p>V tej situaciji je treba razporeditev pregledati s pomo\u010djo projektivnega biroja ali strokovnjaka za uravnote\u017eenje, da se ugotovijo mo\u017enosti namestitve dostopnih pip iz 2.<sup>tema<\/sup> raven.<br \/>Omenimo, da bo uravnote\u017eenje vezja toliko bolj u\u010dinkovito, kolikor ve\u010dje bo \u0161tevilo oddajnikov, ki jih \u00abnadzorujejo\u00bb ventili 2<sup>tema<\/sup> intenzivnost bo zmerna, z optimalnim \u0161tevilom od 5 do 10 enot.<\/p>\n<p>Na obstoje\u010dih napravah se praviloma nastavi le 2<sup>tema<\/sup> ravni uravnote\u017eenja (in vi\u0161jih ravni) zadostuje za doseganje pravilnega rezultata. \u010ce bi kljub temu pri nekaterih posameznih antenah \u0161e vedno prihajalo do motenj, bo vedno mogo\u010de na kraju samem opraviti dodatno uravnote\u017eenje. To bo mogo\u010de pravilno izvesti, saj bo ustrezna skupina oddajnikov pred tem normalno napajana zaradi pravilne nastavitve svojega ventila 2<sup>tema<\/sup> raven.<\/p>\n<p>\u010ce se namestijo izravnalne pipe 2<sup>tema<\/sup> \u010ce ta raven ni izvedljiva, bo treba razmisliti o zahtevnem na\u010drtu dostopa do vseh prostorov.<br \/>\u010ce se \u017ee odlo\u010dimo za to drago re\u0161itev, lahko to izkoristimo za preu\u010ditev mo\u017enosti vgradnje najnovej\u0161e generacije termostatskih ventilov, ki omogo\u010dajo tudi \u00abdinami\u010dno\u00bb uravnote\u017eenje sistema, katerega prednosti bomo preu\u010dili kasneje.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Hidravli\u010dno dinami\u010dne termostatske armature Danfoss\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec3.jpg\" alt=\"\" width=\"300\" height=\"251\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika 3: Hidravli\u010dno dinami\u010dni termostatski ventili <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Na koncu naj \u0161e omenimo, da je za nastavitev teh ventilov, tako kot pri vseh izravnalnih ventilih, potrebna natan\u010dna za\u010detna hidravli\u010dna nastavitev.<br \/>Kot bomo videli kasneje, \u010de se uravnote\u017eenje izvaja z nastavitvijo pretokov, bo za njihovo dolo\u010ditev \u2013 ob pomanjkanju dokumentacije o obstoje\u010dih napravah \u2013 potrebno sodelovanje projektivnega biroja.<\/p>\n<p class=\"text-justify push-top\">\u00a0<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANALIZA IN STROKOVNO ZNANJE PROIZVAJALCEV<\/h2>\n<\/div>\n<p class=\"text-justify push-top\"><em>Soobstajajo tri generacije izravnalnih ventilov.<\/em><\/p>\n<p><strong>1<sup>era<\/sup> generacija: Stati\u010dne in nevolumetri\u010dne izravnalne pipe ali ventili.<\/strong><br \/>Te pipe ne omogo\u010dajo merjenja pretoka v sistemu.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Nevolumetri\u010dne izravnalne armature\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec18.jpg\" alt=\"\" width=\"650\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\"><em>Slika 4: Nevolumetri\u010dni izravnalni ventili<\/em><\/p>\n<p class=\"text-justify push-top\">Nastavite jih lahko na dva na\u010dina:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Hidravli\u010dna simulacija porazdelitev<\/li>\n<li class=\"pad5\">Uenotenje temperatur povratnega toka anten, ki jih je treba uravnovesiti<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Hidravli\u010dna simulacija distribucijskih omre\u017eij predpostavlja natan\u010den pregled distribucijskega omre\u017eja (dol\u017eine odsekov, premeri itd.), dolo\u010ditev hidravli\u010dnega obna\u0161anja vgrajenih ventilov ter izra\u010dun pretokov, ki jih je treba nastaviti na vsakem odcepu.<br \/>Pri obstoje\u010dih napravah je zbiranje vseh teh podatkov zapleteno, zaradi tega pa negotovosti omejujejo mo\u017enosti, da bi brez te\u017eav dosegli dober rezultat.<\/p>\n<p>Kadar so naprave opremljene s tak\u0161nimi pipami, je najbolj\u0161a re\u0161itev, da se postopek izvede tako, da <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/methode-dequilibrage-equilog\/\" target=\"_blank\" rel=\"noopener noreferrer\">izena\u010denje temperatur povratne vode v sistemskih enotah, ki jih je treba uravnovesiti. <\/a><br \/>Ta najnovej\u0161a metoda bo predstavljena v nadaljevanju.<\/p>\n<p><strong>2<sup>tema<\/sup> generacija: Stati\u010dne in volumetri\u010dne izravnalne pipe ali ventili.<\/strong><br \/>Te pipe omogo\u010dajo merjenje pretoka v sistemu.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Volumetri\u010dni izravnalni ventili\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec5.jpg\" alt=\"\" width=\"451\" height=\"230\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 5: Volumetri\u010dni izravnalni ventili <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> in <a class=\"bleu\" href=\"http:\/\/www.comap.fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">Comap<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Za njihovo nastavitev so na voljo tri metode:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Hidravli\u010dna simulacija porazdelitev<\/li>\n<li class=\"pad5\">Nastavitev in nadzor pretoka z merjenjem na kraju samem<\/li>\n<li class=\"pad5\">Uenotenje temperatur povratne vode v sistemih, ki jih je treba uravnovesiti<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">\u010ce prvo re\u0161itev izklju\u010dimo zaradi te\u017eav, ki jih povzro\u010da pri obstoje\u010dih napravah, je treba opozoriti, da tudi pri delu z nastavitvijo pretokov sodelovanje projektivnega biroja ni potrebno za dolo\u010ditev pretoka, ki ga je treba nastaviti na vsaki anteni, ki jo je treba uravnovesiti.<br \/>Pri obstoje\u010dih napravah ostaja najpreprostej\u0161a re\u0161itev izena\u010denje temperatur povratne vode.<\/p>\n<p><strong>3<sup>tema<\/sup> generacija: dinami\u010dne izravnalne pipe ali ventili<\/strong><br \/>Gre za najnovej\u0161o generacijo izravnalnih ventilov, namenjenih vgradnji na <strong>krogi s spremenljivim pretokom <\/strong>kot so tisti, opremljeni s termostatskimi pipami.<\/p>\n<p>Razlikujemo med dvema vrstama pip:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Izravnalne pipe ali ventili \u00ab <em>regulatorji razlike v tlaku <\/em>\u00bb<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Ventili za regulacijo razlike v tlaku\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec7.jpg\" alt=\"\" width=\"650\" height=\"207\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 6: Ventili za regulacijo razlike v tlaku <a class=\"bleu\" href=\"http:\/\/honeywell.com\/country\/fr\/Pages\/home.aspx\" target=\"_blank\" rel=\"noopener noreferrer\">Honeywell<\/a> in <a class=\"bleu\" href=\"http:\/\/www.danfoss.com\/france\/\" target=\"_blank\" rel=\"noopener noreferrer\">Danfoss<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">V sistemu, opremljenem s termostatskimi ventili (Rth), se ob njihovem \u00abzapiranju\u00bb pove\u010da razlika v dovodnem tlaku (DP) v odcepu. To pove\u010danje DP nato prepre\u010duje zapiranje Rth in povzro\u010di pove\u010danje pretoka v oddajnikih, katerih termostatske pipe se \u0161e niso zaprle.<br \/>V tej situaciji ventil za regulacijo razlike v tlaku zazna pove\u010danje razlike v tlaku in se \u00abzapre\u00bb, da bi jo ponovno vzpostavil.<\/p>\n<p>Nekateri modeli, kot so tisti na zgornji fotografiji, niso volumetri\u010dni in zato ne omogo\u010dajo merjenja reguliranih pretokov. Njihovo nastavljanje ali preverjanje nastavitev je treba opraviti z merjenjem temperatur povratnega toka.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>tema<\/sup> vrsta dinami\u010dnih izravnalnih ventilov: avtomatski izravnalni ventili<\/strong> <em>(imenovani tudi samouravnote\u017eni ali neodvisni od dovodnega tlaka ali PIBCV ali regulator pretoka)<\/em><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Tako imenovani \u00abavtomatski\u00bb izravnalni ventili\u00bb\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec8.jpg\" alt=\"\" width=\"250\" height=\"253\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 7: Tako imenovani \u00abavtomatski\u00bb izravnalni ventili\u00bb <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Te pipe so bile zasnovane tako, da omogo\u010dajo <strong>nastavitev ene same kon\u010dne enote<\/strong> kot je na primer grelna baterija v klimatski enoti ali ventilatorskem konvektorju.<br \/>Lahko so opremljeni z motorjem, kar omogo\u010da regulacijo naprave v najbolj\u0161ih hidravli\u010dnih delovnih pogojih.<\/p>\n<p>V\u010dasih se uporabljajo za uravnote\u017eenje anten, ki vsebujejo <strong>ve\u010d oddajnikov, opremljenih z dvosmernimi regulacijskimi ventili<\/strong> kot so radiatorji, opremljeni s termostatskimi ventili. Avtomatski izravnalni ventili tako nadome\u0161\u010dajo ventile za regulacijo razlike v tlaku, ki so obi\u010dajno predvideni za tak\u0161en primer.<\/p>\n<p>Ta situacija prvotno ni bila predvidena in ni omenjena v tehni\u010dnih specifikacijah proizvajalcev. Dejansko delovanje avtomatskega izravnalnega ventila v tem primeru ni povsem optimalno in je v tej situaciji podobno delovanju stati\u010dnega izravnalnega ventila.<\/p>\n<p>To delovanje lahko preu\u010dimo v \u010dlanku: <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u00abSamodejno uravnote\u017eenje: pogoji za uspeh\u00bb<\/a><\/p>\n<p>V komentarjih na koncu tega \u010dlanka bomo predstavili stali\u0161\u010de dveh velikih proizvajalcev.<br \/>Tako podjetje IMI \u2013 Hydronic pojasnjuje:<br \/><em>\u00abGlede vgradnje avtomatskih ventilov (PIBCV, v tem primeru regulator pretoka) v omre\u017ejih s spremenljivim pretokom (na primer v stanovanjih, opremljenih s termostatskimi pipami) nam na\u0161e vloge strokovnjakov ali industrijskih specialistov za hidravliko narekujejo, da moramo zavzeti tehni\u010dno brezhibno stali\u0161\u010de. \u010ceprav moramo priznati, da se vgradnja PIBCV na vhodu v stanovanja \u0161iri, te prakse iz eti\u010dnih razlogov ne moremo spodbujati.\u00bb<\/em><\/p>\n<p>Oventrop, ki je glede iste teme bolj pragmati\u010den, navaja <em>da je, \u010deprav gre za tehni\u010dno kompromisno re\u0161itev na podro\u010dju hidravlike, splo\u0161na nastavitev, dose\u017eena z avtomatskimi ventili, vseeno precej bolj\u0161a od tiste, ki jo dose\u017eemo s stati\u010dnimi ventili in ventili za uravnavanje tlaka, saj so ti najpogosteje le malo ali sploh niso nastavljeni.<\/em><\/p>\n<p>Res je, da nastavitev ventilov za regulacijo diferencialnega tlaka pogosto ni zadovoljiva, zlasti pri modelih, ki niso volumetri\u010dni. \u010ce ne delamo na podlagi meritev temperature povratnega toka, je njihovo nastavljanje mogo\u010de le na podlagi hipoteti\u010dnega izra\u010duna izgube tlaka. \u010ce \u017eelimo uravnote\u017eenje izvesti z merjenjem pretoka, je nujno izbrati volumetri\u010dne modele, pri \u010demer ve\u010d blagovnih znamk ponuja prilagodljive volumetri\u010dne ventile.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Volumetri\u010dni ventil, opremljen z Oventropovim ventilom za regulacijo diferencialnega tlaka\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec17.jpg\" alt=\"\" width=\"513\" height=\"150\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 6 bis: Volumetri\u010dni ventil, opremljen z ventilom za regulacijo diferencialnega tlaka <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Na koncu je torej treba poudariti, da ne smemo zamenjati \u00abvgradnje pip\u00bb in \u00abnastavitve pip\u00bb, ne glede na generacijo vgrajenih modelov.<\/p>\n<p>Tako kot pri prej\u0161njih generacijah je treba tudi dinami\u010dne izravnalne ventile natan\u010dno nastaviti. To nastavitev je mogo\u010de opraviti s simulacijo in\/ali merjenjem pretoka in\/ali merjenjem temperatur v povratnem vodovodu. Ta tema bo podrobneje obravnavana v naslednjem odstavku.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>METODE IZENA\u010cEVANJA<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">V obstoje\u010dih sistemih daljinskega ogrevanja, <strong>tri metodologije <\/strong>Danes se uporabljajo metode za za\u010detno nastavitev izravnalnih ventilov.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>1<sup>era<\/sup> metoda: Simulacija hidravli\u010dnega obna\u0161anja omre\u017eij<\/strong><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Simulacija  hidravli\u010dnega obna\u0161anja omre\u017eij\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec9.jpg\" alt=\"\" width=\"492\" height=\"446\" \/><\/p>\n<p class=\"text-justify push-top\">Na obstoje\u010dih napravah je teoreti\u010dno mogo\u010de opraviti meritve, potrebne za oceno pretokov in tlakovnih izgub v krogih, da bi na podlagi izra\u010dunov dolo\u010dili prednastavitev izravnalnih ventilov. Vendar gre za zahtevno \u00abiskanje sledi\u00bb, razen \u010de se uporabijo razporedni na\u010drti, ki so redko na voljo.<\/p>\n<p>To mo\u017enost je \u0161e posebej razvil <a class=\"bleu\" href=\"http:\/\/edipa.fr\/LibrairieTechnique\/Auteur?auteur=FRIDMANN%20Pierre&amp;page=1\" target=\"_blank\" rel=\"noopener noreferrer\">Gospod Pierre Fridmann<\/a> zahteva mo\u017enost, da se nato preveri rezultat vseh izvedenih prednastavitev, bodisi z merjenjem pretoka bodisi z merjenjem temperature povratne vode.<\/p>\n<p>Ta metoda se nana\u0161a predvsem na nove ali novej\u0161e naprave, pri katerih \u0161e ni pri\u0161lo do nepredvidljivih oblog in za katere so na voljo vsi potrebni podatki za izra\u010dun.<br \/>Uporablja se lahko zlasti za dolo\u010danje razlik v tlaku, ki jih je treba nastaviti na ventilih za \u00abregulacijo diferencialnega tlaka\u00bb, ki imajo nastavitvene oznake v enotah tlaka.<br \/>Na podlagi rezultatov simulacije je mogo\u010de opraviti prednastavitev armatur, preden se nato na kraju samem preverijo in prilagodijo dejansko dose\u017eeni pretoki vode ali temperature povratne vode.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>2<sup>tema<\/sup> metoda: Izra\u010dun, nastavitev in nadzor pretokov, ki jih je treba prenesti<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Metodologija vklju\u010duje izra\u010dun in nastavitev pretokov, ki jih je treba prena\u0161ati. Za to so seveda potrebne tako imenovane \u00abvolumetri\u010dne\u00bb armature, stati\u010dne ali dinami\u010dne, ki omogo\u010dajo merjenje pretokov.<br \/>Zato se ne uporablja za <strong>nevolumetri\u010dne pipe<\/strong> kot so preprosti regulacijski ventili, name\u0161\u010deni na izhodu radiatorjev, pa tudi na dnu stebrov in predvsem na povratnem vodu zank talnega ogrevanja.<\/p>\n<p>Opozoriti je treba tudi, da nekateri ventili za regulacijo diferencialnega tlaka niso volumetri\u010dni. Njihovo nastavljanje ali preverjanje nastavitev je treba izvajati izklju\u010dno z merjenjem temperatur povratnega toka.<\/p>\n<p>Pri obstoje\u010dih napravah mora projektivni urad za dolo\u010ditev pretokov, ki jih je treba nastaviti, opraviti meritve, potrebne za oceno toplotnih izgub, ki ustrezajo vsaki od ogrevalnih anten, ki jih je treba obravnavati.<br \/>Za to bo moral izra\u010dunati toplotne izgube standardnih prostorov in posebnih prostorov (pod teraso, ob stre\u0161nem zidu itd.). Nato, kar je pogosto zelo zahtevno, jih bo moral pravilno dodeliti vsaki od anten, ki jih je treba nastaviti.<\/p>\n<p>Za nastavitev pretokov je potrebna merilna oprema, \u010de pa ventili niso dinami\u010dni, pa je potrebna uporaba posebne metodologije.<br \/>Eno od teh metod bo mogo\u010de pridobiti na <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-debit.htm\" target=\"_blank\" rel=\"noopener noreferrer\">E-usposabljanje Xpair<\/a> ali na <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulator.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Nadzor pretoka\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec10.jpg\" alt=\"\" width=\"551\" height=\"224\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 9: Nadzor pretoka \u2013 Vir <a class=\"bleu\" href=\"http:\/\/www.oventrop.de\/?countrySelect=fr-FR\" target=\"_blank\" rel=\"noopener noreferrer\">Oventrop<\/a> in merilna torba <a class=\"bleu\" href=\"http:\/\/www.imi-hydronic.com\/fr\/\" target=\"_blank\" rel=\"noopener noreferrer\">IMI Hydronic<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">\u010ce so pipe, ki jih je treba nastaviti,<strong> dinami\u010dnega tipa <\/strong>Nastavitev pretoka je mogo\u010de opraviti preprosteje, brez uporabe posebne metode, razen preverjanja, ali ima najslab\u0161e oskrbljena pipa zadosten diferencialni tlak v napajalnem sistemu.<\/p>\n<p>Pri nekaterih dinami\u010dnih ventilih z nastavljivim pretokom je mogo\u010de prednastavitev opraviti brez merjenja, vendar to ne sme odvezati od kon\u010dnega merjenja dose\u017eenih pretokov, ko bodo vsi ventili \u017ee prednastavljeni.<br \/>Pri modelih, ki nimajo ozna\u010denih pretokov, zlasti pri ventilih za regulacijo diferencialnega tlaka, ni mogo\u010de nastaviti pretokov brez njihovega dejanskega merjenja (\u010de so poleg tega volumetri\u010dnega tipa).<\/p>\n<p>Ko bodo vsi dinami\u010dni ventili nastavljeni ali prednastavljeni \u2013 \u010de gre za volumetri\u010dne ventile \u2013, se bo temeljito uravnote\u017eenje zaklju\u010dilo z merjenjem vseh pretokov v sistemu, da se zagotovi, da so bile hidravli\u010dne interakcije med vejami ustrezno obravnavane.<br \/>Spomnimo se namre\u010d, da \u017ee nekaj slabo oskrbljenih odcepov zadostuje, da se mora preostali del distribucijskega omre\u017eja pregreti, hidravli\u010dno obna\u0161anje vodov, zlasti obstoje\u010dih, pa pogosto prina\u0161a \u0161tevilna presene\u010denja.<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\"><strong>3<sup>tema<\/sup> metoda: Merjenje in uravnavanje temperature povratne vode med ogrevalno sezono<\/strong><\/li>\n<\/ul>\n<p class=\"text-justify push-top\">Ta novej\u0161a re\u0161itev, imenovana \u00abmetoda EQUILOG\u00bb, ob delovanju ogrevalnega sistema in stabilizirani izhodni temperaturi vklju\u010duje <strong>merjenje temperature povratne vode <\/strong>antene je treba uravnovesiti in izena\u010diti tako, da so vse antene, ki jih je treba nastaviti, enako \u00abvro\u010de\u00bb.<\/p>\n<p>Postopek, ki na prvi pogled deluje \u00abpreprosto\u00bb, je bil in je \u0161e vedno predmet povsem razumljivih kritik s strani konkurentov. O tem si lahko preberete <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-hydraulique-methode-simple.htm\" target=\"_blank\" rel=\"noopener\">\u00abHidravli\u010dno uravnote\u017eenje: novosti pri preprosti metodi\u00bb. <\/a>Vendar pa lahko ugotovimo, da je bilo do danes na ve\u010d sto lokacijah na ta na\u010din obdelanih ve\u010d kot 80.000 stanovanjskih enot, in sicer pod ugodnimi pogoji donosnosti.<\/p>\n<p>Po uravnote\u017eenju bodo antene imele primerljive temperature na povratnem toku ter temperaturne razlike med dovodnim in povratnim tokom <em>(*)<\/em>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Uenotenje temperatur vode v ogrevalnem krogu\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec12.gif\" alt=\"\" width=\"573\" height=\"229\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 11: Izravnava(*) temperatur vode v ogrevalnem krogu<\/em><\/p>\n<p class=\"text-justify push-top\"><em>(*) \u010ce to omogo\u010da hidravli\u010dni sistem, je seveda mogo\u010de za vsako vejo nastaviti razli\u010dne temperature vode, da se upo\u0161tevajo lokalni ukrepi za izolacijo. <\/em><br \/><em>Vendar pa ugotavljamo, da pri stavbah, na katerih so bile izvedene enotne toplotne sanacije (zamenjava vseh odpiralnih elementov, izolacija vseh zunanjih navpi\u010dnih sten), uravnote\u017eenje <u>za\u010detni ali naknadni<\/u> To se dose\u017ee z izena\u010ditvijo temperature vode, kar zadostuje za dober rezultat. <\/em><br \/><em>Nato je mogo\u010de prilagoditi ogrevalno mo\u010d s preprostim nastavljanjem temperature vode na izhodu iz kotlovnice (nastavitev krivulje ogrevanja).<\/em><\/p>\n<p>Postopek, ki se lahko uporablja za vse vrste pip, je bilo mogo\u010de optimizirati zahvaljujo\u010d napredku na podro\u010dju infrarde\u010de termometrije in raziskavam, ki jih je opravil GMTI94 \u2013 GEFEn.<br \/>Njegovo delovanje bomo lahko preu\u010dili na <a class=\"bleu\" href=\"http:\/\/formation.xpair.com\/equilibrage-hydraulique\/module\/equi-temp.htm\" target=\"_blank\" rel=\"noopener noreferrer\">E-usposabljanje Xpair<\/a> ali na <a class=\"bleu\" href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564?AcceptCookies=check\" target=\"_blank\" rel=\"noopener noreferrer\">Simulator<\/a>.<\/p>\n<p>Glavna prednost te metodologije je, da se pri omre\u017ejih z obi\u010dajnimi dimenzijami ni treba ukvarjati z izra\u010duni izgub ali meritvami napeljav. Zaradi tega je \u0161e posebej primerna za obstoje\u010de napeljave, za katere so arhivski podatki redko na voljo.<\/p>\n<p>Ta postopek, ki se je eksperimentalno za\u010del izvajati v 2000-ih, je bil patentiran v Franciji, nedavno pa tudi v 15 evropskih dr\u017eavah.<br \/>Metodo \u00abEQUILOG\u00bb uporabljajo zlasti <em>\u00ab <\/em><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><em>podjetje MAPSEC <\/em><\/strong><\/a><em>\u00bb(*) <\/em>v imenu razli\u010dnih podjetij za upravljanje in namestitev (Dalkia, Cofely-Soccram, Idex itd.).<br \/><em>(*) MAPSEC, 80 rue de Paris, 93100 Montreuil, tel.: 01 48 59 06 05 \u2013 <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr<\/a><\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Cirkulacijsko \u010drpalo\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec11.jpg\" alt=\"\" width=\"250\" height=\"187\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika \u0161t. 10: Nadzor temperature vode \u2013 Vir <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/\" target=\"_blank\" rel=\"noopener noreferrer\">Mapsec<\/a><\/em><\/p>\n<p class=\"text-justify push-top\">Na koncu naj \u0161e omenimo, da v <a href=\"http:\/\/conseils.xpair.com\/actualite_experts\/equilibrage-dynamique-chauffage.htm\" target=\"_blank\" rel=\"noopener\">\u010dlanek o dinami\u010dnih izravnalnih ventilih<\/a> Kot je bilo omenjeno v prej\u0161njem odstavku, in\u017eenir, ki zastopa podjetje Oventrop, to navaja v komentarjih na koncu dokumentacije.<br \/><em>\u00abTudi pri obstoje\u010dih sistemih je po mojem mnenju uravnote\u017eenje s poenotenjem temperatur povratnega toka najbolj\u0161a metoda, \u010de je izbrani temperaturni padec ustrezen.\u00ab.<br \/>Kljub vsemu je ta metoda \u010dasovno zahtevna in jo strokovnjaki za vgradnjo v stanovanjih te\u017eko sprejemajo, kadar jo je treba izvesti ro\u010dno.<br \/>\u00bbObstajajo pipe, ki to opravijo samodejno, vendar je cena druga\u010dna.\u00ab<\/em><\/p>\n<p>Res je, da je uravnote\u017eenje s poenotenjem temperatur povratnega toka v preteklosti zahtevalo dolge \u010dakalne dobe za toplotno stabilizacijo, vendar najnovej\u0161i napredek danes omogo\u010da, da se tega izognemo, zaradi \u010desar je trajanje postopkov postalo zelo konkuren\u010dno.<\/p>\n<p>Poleg tega bi bilo dejansko mogo\u010de razmisliti o samodejnem doseganju in dolgoro\u010dnem vzdr\u017eevanju uravnote\u017eenosti s poenotenjem temperatur povratnega toka. Vendar bi to ob trenutnem stanju tehnologije zahtevalo namestitev in elektri\u010dno napajanje avtomatskih motoriziranih izravnalnih ventilov, povezanih z avtomatskim krmilnikom ali sistemom za upravljanje zgradb.<br \/>Z gospodarskega vidika je to zaenkrat \u0161e te\u017eko predstavljivo, vsaj kar zadeva obstoje\u010de naprave.<\/p>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>ANALIZA IN STROKOVNO ZNANJE MONTERJEV<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Predvsem je treba jasno razlikovati med odstranjevanjem usedlin (kadar je to potrebno) in vgradnjo izravnalnih ventilov ter samim za\u010detnim nastavljanjem le-teh.<\/p>\n<p>Ne glede na vrsto pipe je namre\u010d za podjetje, ki se ukvarja z vgradnjo ali odstranjevanjem usedlin, privla\u010dno, da v svojo ponudbo vklju\u010di storitev zagon, ne da bi vedno lahko dolo\u010dilo vse parametre.<\/p>\n<p>Seveda si lahko predstavljamo, da bi eno samo podjetje lahko izvedlo celotno operacijo ponovnega uravnote\u017eenja, vendar mora v tem primeru razpolagati z ekipami, ki imajo zelo razli\u010dno prakti\u010dno in teoreti\u010dno znanje.<\/p>\n<p>Na splo\u0161no je torej pri izbiri podjetja, ki bo izvedlo uravnote\u017eenje, potrebna izjemna previdnost. Gre za zahtevno tehni\u010dno specializacijo, pri kateri se pogosto pojavljajo neuspehi, saj je preverjanje kakovosti opravljenega dela te\u017eko izvedljivo.<\/p>\n<p>\u010ceprav bi to pomenilo dodatne stro\u0161ke, se ne bomo obotavljali, da posamezne dejavnosti lo\u010dimo tako, da bodo faze \u0161tudije in\/ali razvoja izvedli strokovnjaki s tega podro\u010dja.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"radiator\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec13.jpg\" alt=\"\" width=\"450\" height=\"173\" \/><\/p>\n<p class=\"text-justify push-top\">Dober na\u010din izbire je, da se med posvetovanjem pozanimate, kak\u0161na metoda bo uporabljena, in da se natan\u010dno pojasni, katere podatke boste prejeli po posegu.<br \/>Vsaka nejasnost ali oklevanje pri odgovorih na katero koli od teh dveh to\u010dk bo nedvomno znak slabo opravljene naloge.<\/p>\n<p>\u010ce podjetje deluje na podlagi meritev pretoka ali hidravli\u010dne simulacije, se lahko zahteva, da ponudba vklju\u010duje kon\u010dni popust:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Podrobni izra\u010dun izgub <strong>v skladu z vsako pipo, ki jo je treba obdelati<\/strong> in ki so privedli do dolo\u010ditve pretokov, ki jih je treba urediti. Na ta na\u010din se bo mogo\u010de prepri\u010dati, da ciljni pretoki niso rezultat grobih ocen.<\/li>\n<li class=\"pad5\">Iz mre\u017ee <strong>certificirana<\/strong> izmerjene pretoke <u>po zaklju\u010dku nastavitve vseh pip<\/u> (in se ne zadovoljiti zgolj s tabelo teoreti\u010dno predvidenih pretokov). Na ta na\u010din se bo mogo\u010de prepri\u010dati, da so bile hidravli\u010dne interakcije med antenami, ki jih je treba nastaviti, dejansko upo\u0161tevane, in po potrebi to tudi preveriti.<\/li>\n<\/ul>\n<p class=\"text-justify push-top\">\u010ce podjetje deluje na podlagi merjenja temperatur povratnega toka, se lahko zahteva, da predlog vklju\u010duje:<\/p>\n<ul class=\"text-justify push-top\">\n<li class=\"pad5\">Nekaj ustreznih referenc ali, \u0161e bolje, predlo\u017eitev vsaj enega podrobnega poro\u010dila o prej izvedeni operaciji. Na ta na\u010din se bo mogo\u010de prepri\u010dati o izku\u0161njah kandidata, saj je na\u010delo te metode sicer staro, vendar se ga v celoti obvlada \u0161ele od nedavnega.<\/li>\n<li class=\"pad5\">Prikaz grafa <strong>potrjen, popoln in podrobno opisan<\/strong> izmerjene temperature povratnega toka,<strong> pred in po uravnote\u017eenju<\/strong>, skupaj z navedbo stabiliziranih izhodnih temperatur, pri katerih so bile te meritve opravljene. Na ta na\u010din bo mogo\u010de zagotoviti kakovost opravljenega dela.<\/li>\n<\/ul>\n<\/div>\n<div class=\"block full\" style=\"text-align: left;\">\n<div class=\"block-title\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>DONOSNOST IN PRIHRANKI ENERGIJE<\/h2>\n<\/div>\n<p class=\"text-justify push-top\">Ni enostavno napovedati, koliko energije bo mogo\u010de prihraniti z uravnote\u017eenjem.<br \/>\u010ceprav bi ga v primeru popolnoma uspe\u0161nega izena\u010devanja lahko ocenili na podlagi karte za\u010detnih sobnih temperatur, je ta v resnici zelo te\u017eko razumljiva.<br \/>V vsakem primeru pa je treba, \u010de se odlo\u010dimo za to metodo ocenjevanja, upo\u0161tevati zapise, pridobljene v zelo hladnem obdobju in brez kakr\u0161nih koli brezpla\u010dnih virov energije (son\u010dno sevanje, elektri\u010dne naprave itd.), ne pa trenutnih meritev.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Primer bele\u017eenja sobnih temperatur, na katere vplivajo brezpla\u010dni dotoki\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec15.jpg\" alt=\"\" width=\"400\" height=\"235\" \/><\/p>\n<p class=\"text-center push-top\" style=\"text-align: center;\"><em>Slika 15: Primer zapisa sobnih temperatur, na katere vplivajo neza\u017eeleni vplivi<\/em><\/p>\n<p class=\"text-justify push-top\">\u0160e bolj zahtevno pa je upo\u0161tevanje namestitve uravnote\u017eevalnih ventilov, ki jih bo mogo\u010de dejansko nastaviti. Pri obstoje\u010dih ogrevalnih sistemih se namre\u010d uravnote\u017eenje obi\u010dajno izvaja le na ventilih, ki so dostopni iz 2.<sup>tema<\/sup> raven (glej 2<sup>tema<\/sup> \u00a7). Posledi\u010dno je bolj ali manj uspe\u0161na uvedba tega 2<sup>tema<\/sup> Raven je klju\u010dni parameter za oceno pri\u010dakovanega prihranka energije.<\/p>\n<p>V zvezi s tem podjetje MAPSEC uporablja tako imenovano metodologijo <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/ecomapsec\/\" target=\"_blank\" rel=\"noopener noreferrer\">REQUILOG<\/a> kar mu omogo\u010da, da na podlagi karte temperatur povratne vode, izmerjenih na vi\u0161ini pip, ki jih je treba nastaviti, oceni obseg neravnovesja, ki ga bo mogo\u010de dejansko odpraviti.<br \/>Poleg tega, kadar je to mogo\u010de, pred uravnote\u017eevalnimi postopki, ki so mu zaupani, poteka diagnosti\u010dni postopek, ki vklju\u010duje to oceno, kar odlo\u010devalcu omogo\u010da, da bolje presodi, ali je izvedba postopka smiselna ali ne.<\/p>\n<p>Na koncu naj \u0161e omenimo, da bo prihranek energije, ki izhaja iz postopka uravnote\u017eenja, zahteval naknadno sodelovanje tehnika, odgovornega za nastavitev krmilnega sistema.<br \/>\u010ce bi namre\u010d uravnote\u017eenje na koncu pomenilo, da bi prostore, ki so bili sprva najslab\u0161e ogrevani, pripeljali na raven tistih, ki so najbolje ogrevani, to ne bi pomenilo prihranka energije\u2026<\/p>\n<p>Na splo\u0161no se zdi, da zna\u0161a povpre\u010dna % prihranka energije po ponovnem uravnote\u017eenju porazdelitve ogrevanja okoli 7%, pri \u010demer se nalo\u017eba amortizira v pribli\u017eno 2 do 3 letih, \u010de v sistemu ni potrebna zamenjava ventilov ali je ta potrebna le v majhnem obsegu.<\/p>\n<p>Do decembra 2014 je bilo mogo\u010de te ukrepe vklju\u010diti v sistem certifikatov za var\u010devanje z energijo s pav\u0161alnim odstotkom prihranka energije v vi\u0161ini 10%.<br \/>Ustrezni obrazci BAR in BAT SE 04 se trenutno spreminjajo. Predvidoma bodo ponovno objavljeni pod drugimi poimenovanji v naslednjem ministrskem odloku o CEE.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"gumb ECO\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec14.jpg\" alt=\"\" width=\"250\" height=\"180\" \/><\/p>\n<p class=\"text-justify push-top\">Za zaklju\u010dek pa ena gotovost: postopki uravnote\u017eenja so na splo\u0161no popolnoma donosni, \u010de se izvajajo strogo.<\/p>\n<p>Najbolj\u0161i dokaz za to je delo, ki ga opravlja slu\u017eba za uravnote\u017eenje podjetja Dalkia v regiji IdF(*), ustanovljena pred pribli\u017eno desetimi leti za uporabo metode EQUILOG in ki jo trenutno vodi gospod Christophe Tillay.<br \/>Na spletni strani Xpair si bo mogo\u010de prebrati poro\u010dilo o enem od njihovih projektov v \u010dlanku <a class=\"bleu\" href=\"http:\/\/conseils.xpair.com\/actualite_experts\/exemple-operation-equilibrage-egalisation-temperatures-retour.htm\" target=\"_blank\" rel=\"noopener noreferrer\">\u00abPostopek uravnote\u017eenja s poenotenjem temperatur povratnega toka\u00bb.<\/a><\/p>\n<p><em>(*) Dalkia Ile-de-France, Oddelek za uravnote\u017eenje, 28 Boulevard de Pesaro, 92 751 NANTERRE CEDEX Tel.: 01 55 67 68 97 <\/em><\/p>\n<p>Ve\u010d sto uravnote\u017eevalnih posegov, ki jih je izvedla ta slu\u017eba, je bilo opravljenih izklju\u010dno na nepremi\u010dninskih kompleksih, ki jih dru\u017eba upravlja v okviru pogodb MF (pogodba s pav\u0161alnim zneskom) ali MT (pogodba o temperaturi). Pri tej vrsti pogodb, ki niso dovolj raz\u0161irjene, stranka upravljavcu letno pla\u010da pav\u0161alni znesek (ali znesek, popravljen glede na DJU) v zameno za zagotovilo optimalnega ogrevanja.<\/p>\n<p>Za oskrbo z gorivom je v tem primeru v celoti odgovorno upravljalsko podjetje. Njegov glavni interes je torej, da jo zmanj\u0161a, ne da bi pri tem ogro\u017eal ustrezno ogrevanje za stranko, saj bo celoten prihranek energije pripadel njemu.<\/p>\n<p>Tak\u0161en posel seveda spodbuja izvajalca, da objekt upravlja \u010dim bolje in mu dodeli svoje najbolj\u0161e ekipe. Z okoljskega vidika je situacija tako optimalna.<br \/>Stranka pa ima brez posebnih dodatnih stro\u0161kov zagotovljeno trajno in ustrezno nastavljeno ogrevanje ter zagotovilo, da bo ob izteku pogodb, ki obi\u010dajno trajajo 8 let, prejela napravo, ki je vzdr\u017eevana v najbolj\u0161em mo\u017enem stanju.<\/p>\n<p>Uravnote\u017eenja, ki jih je izvedla slu\u017eba za uravnote\u017eenje podjetja Dalkia IdF, so bila torej financirana iz lastnih sredstev in se v nekaj letih amortizirala zaradi prihrankov energije, ki so nastali.<br \/>Ohranjanje in razvoj te storitve v obdobju 10 let je neizpodbiten dokaz dobre donosnosti tovrstnih dejavnosti.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive center aligncenter\" title=\"Graf uravnote\u017eenja\" src=\"http:\/\/media.xpair.com\/conseil\/regulation\/equilibrage-mapsec16.jpg\" alt=\"\" width=\"400\" height=\"250\" \/><\/p>\n<\/div>\n<div class=\"block full\">\n<div class=\"block-title\" style=\"text-align: left;\">\n<h2>\u00a0<\/h2>\n<h2>\u00a0<\/h2>\n<h2>SKLEP<\/h2>\n<\/div>\n<p class=\"text-justify push-top\" style=\"text-align: left;\">Zmanj\u0161anje porabe energije v na\u0161em obstoje\u010dem sistemu skupinskih ogrevalnih naprav temelji na izolaciji, pravilni nastavitvi zgorevanja, regulaciji in uravnote\u017eenju.<\/p>\n<p style=\"text-align: left;\">Kljub svojemu velikemu vplivu na nastavitev regulacije in izkoristek kondenzacijskih kotlov (ter sistemov za soproizvodnjo toplote in elektri\u010dne energije) je bila ta zadnja postavka doslej \u0161ibka to\u010dka.<\/p>\n<p style=\"text-align: left;\">Po zelo dolgem premoru ta problem \u0161e nikoli ni bil tako aktualen.<\/p>\n<p style=\"text-align: left;\">Nedavni napredek na podro\u010dju armatur in razvoja naj bi omogo\u010dil bolj\u0161e izkori\u0161\u010danje enega od najpomembnej\u0161ih \u0161e razpolo\u017eljivih virov za var\u010devanje z energijo.<\/p>\n<\/div>\n<h4 class=\"text-primary push-top\" style=\"text-align: left;\"><strong>VIRI IN POVEZAVE<\/strong><\/h4>\n<ul class=\"push-top\">\n<li class=\"pad10\" style=\"text-align: left;\">POJASNILO: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/povzetek\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mise-au-point<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">ZAGON SISTEMA OGREVANJA, PREZRA\u010cEVANJA IN KLIMATIZACIJE: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/zagon\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/commissioning<\/a><\/li>\n<li class=\"pad10\" style=\"text-align: left;\">TERENSKI PREGLED: <a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/revizija\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/audit<\/a><\/li>\n<li style=\"text-align: left;\">PREIZKUS TESNOSTI Zra\u010dnih omre\u017eij:\u00a0<a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">www.mapsec.fr\/mesure-de-letancheite-a-lair-des-reseaux-aeraulique<\/a><a class=\"bleu\" href=\"https:\/\/mapsec.fr\/sl\/mesure-de-letancheite-a-lair-des-reseaux-aerauliques\/\" target=\"_blank\" rel=\"noopener noreferrer\">s<\/a><\/li>\n<li style=\"text-align: left;\">SIMULATOR Nau\u010di se uravnote\u017eevanja: <a href=\"http:\/\/www.edipa.fr\/LibrairieTechnique\/Details\/564\" target=\"_blank\" rel=\"noopener\">www.edipa.fr\/LibrairieTechnique\/Details\/564<\/a><\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Par Patrick DELPECH &#8211; pour la soci\u00e9t\u00e9 MAPSEC &#8211; Mars 2020 Pour les responsables techniques et d\u00e9cideurs (maitres d\u2019ouvrage, syndic, etc.), les nouveaut\u00e9s du secteur, les<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-16263","post","type-post","status-publish","format-standard","hentry","category-non-classe"],"_links":{"self":[{"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/posts\/16263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/comments?post=16263"}],"version-history":[{"count":4,"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/posts\/16263\/revisions"}],"predecessor-version":[{"id":17284,"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/posts\/16263\/revisions\/17284"}],"wp:attachment":[{"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/media?parent=16263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/categories?post=16263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mapsec.fr\/sl\/wp-json\/wp\/v2\/tags?post=16263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}